CLINICAL AND ANGIOGRAPHIC RESULTS OF BALLOON-EXPANDABLE INTRACORONARY STENTS IN RIGHT CORONARY-ARTERY STENOSES

被引:91
作者
LEVINE, MJ
LEONARD, BM
BURKE, JA
NASH, ID
SAFIAN, RD
DIVER, DJ
BAIM, DS
机构
[1] BETH ISRAEL HOSP,DEPT MED,DIV CARDIOVASC,HARVARD THORNDIKE LAB,330 BROOKLINE AVE,BOSTON,MA 02215
[2] CHARLES A DANA RES INST,BOSTON,MA
关键词
D O I
10.1016/0735-1097(90)90582-A
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Balloon-expandable stents were placed successfully in 35 (95%) of 37 patients whose right coronary artery lesion was believed to have a poor short- or long-term prognosis with conventional balloon angioplasty because of prior restenosis or adverse lesion morphology. Quantitative angiography showed a reduction in stenosis diameter from 83 ± 14% to 42 ± 14% after conventional balloon dilation, with a further reduction to - 3 ± 12% after stent placement (p < 0.001). There were no acute stent thromboses, but one patient (with two stents and unstented distal disease) developed subacute thrombosis on day 8 after self-discontinuation of warfarin and was treated with thrombolytic therapy and reflation. Follow-up angiography was performed at 4 to 6 months in 25 patients, demonstrating restenosis (83 ± 13%) in 4 (57%) of 7 patients with multiple stents, but only 3 (17%) of 18 patients with a single stent (p < 0.05). Six of the seven in-stent restenotic lesions were subtotal (80 ± 12%) and were subjected to repeat conventional balloon angioplasty (postdilation stenosis 13 ± 21%). The 18 patients without restenosis had a maximal in-stent diameter stenosis of 29 ± 15%, corresponding to a maximal focal neointimal thickness of 0.68 ± 0.26 mm within the stented segment. These preliminary results suggest that the Schatz-Palmaz stent may be a useful adjunctive device in the performance of coronary angioplasty. © 1990.
引用
收藏
页码:332 / 339
页数:8
相关论文
共 17 条
[1]   PROBLEMS IN THE DEVELOPMENT OF NEW DEVICES FOR CORONARY INTERVENTION - POSSIBLE ROLE FOR A MULTICENTER REGISTRY [J].
BAIM, DS ;
DETRE, K ;
KENT, K .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (05) :1389-1392
[2]  
BAIM DS, 1989, CIRCULATION S2, V80, P174
[3]  
DETRE K, 1988, NEW ENGL J MED, V318, P165
[4]   TRANSLUMINALLY-PLACED COILSPRING ENDARTERIAL TUBE GRAFTS - LONG-TERM PATENCY IN CANINE POPLITEAL ARTERY [J].
DOTTER, CT .
INVESTIGATIVE RADIOLOGY, 1969, 4 (05) :329-+
[5]   INTRACORONARY STENTS - WILL THEY FULFILL THEIR PROMISE AS AN ADJUNCT TO ANGIOPLASTY [J].
ELLIS, SG ;
TOPOL, EJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (06) :1425-1430
[6]  
LEON MB, 1989, CIRCULATION S2, V80, P174
[7]   ATHEROSCLEROTIC RABBIT AORTAS - EXPANDABLE INTRALUMINAL GRAFTING [J].
PALMAZ, JC ;
WINDELER, SA ;
GARCIA, F ;
TIO, FO ;
SIBBITT, RR ;
REUTER, SR .
RADIOLOGY, 1986, 160 (03) :723-726
[8]   PLACEMENT OF BALLOON-EXPANDABLE INTRALUMINAL STENTS IN ILIAC ARTERIES - 1ST 171 PROCEDURES [J].
PALMAZ, JC ;
GARCIA, OJ ;
SCHATZ, RA ;
REES, CR ;
ROEREN, T ;
RICHTER, GM ;
NOELDGE, G ;
GARDINER, GA ;
BECKER, GJ ;
WALKER, C ;
STAGG, J ;
KATZEN, BT ;
DAKE, MD ;
PAOLINI, RM ;
MCLEAN, GK ;
LAMMER, J ;
SCHWARTEN, DE ;
TIO, FO ;
ROOT, HD ;
ROGERS, W .
RADIOLOGY, 1990, 174 (03) :969-975
[9]   EARLY AND LATE RESULTS OF INTRACORONARY ARTERIAL STENTING AFTER CORONARY ANGIOPLASTY IN DOGS [J].
ROUBIN, GS ;
ROBINSON, KA ;
KING, SB ;
GIANTURCO, C ;
BLACK, AJ ;
BROWN, JE ;
SIEGEL, RJ ;
DOUGLAS, JS .
CIRCULATION, 1987, 76 (04) :891-897
[10]   SELF-EXPANDING ENDOVASCULAR PROSTHESIS - AN EXPERIMENTAL-STUDY [J].
ROUSSEAU, H ;
PUEL, J ;
JOFFRE, F ;
SIGWART, U ;
DUBOUCHER, C ;
IMBERT, C ;
KNIGHT, C ;
KROPF, L ;
WALLSTEN, H .
RADIOLOGY, 1987, 164 (03) :709-714