BEAM TESTS OF THE ZEUS BARREL CALORIMETER

被引:221
作者
BERNSTEIN, A
BIENZ, T
CALDWELL, A
CHEN, L
DERRICK, M
GIALAS, I
HAMRI, A
IMLAY, R
KARTIK, S
KIM, HJ
KINNEL, T
KREUTZMANN, H
LI, CG
LIM, JN
LOVELESS, R
LU, B
MALLIK, U
MCLEAN, KW
MCNEIL, R
METCALF, W
MUSGRAVE, B
OH, BY
PARK, S
PARSONS, JA
REEDER, D
REPOND, J
RITZ, S
ROCO, MTP
SANDLER, PH
SCIULLI, F
SMITH, WH
TALAGA, RL
TZANAKOS, G
WAI, L
WANG, MZ
WHITMORE, J
WU, J
YANG, S
机构
[1] NEVIS LABS,IRVINGTON,NY
[2] COLUMBIA UNIV,NEW YORK,NY 10027
[3] LOUISIANA STATE UNIV,BATON ROUGE,LA 70803
[4] COLUMBIA UNIV,NEW YORK,NY 10027
[5] UNIV WISCONSIN,MADISON,WI 53706
[6] VIRGINIA POLYTECH INST & STATE UNIV,BLACKSBURG,VA 24061
[7] LOUISIANA STATE UNIV,BATON ROUGE,LA 70803
[8] OHIO STATE UNIV,COLUMBUS,OH 43210
[9] PENN STATE UNIV,UNIV PK,PA 16802
关键词
D O I
10.1016/0168-9002(93)91078-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A fully compensating uranium-scintillator calorimeter was constructed for the ZEUS detector at HERA. Several of the barrel calorimeter modules were subjected to beam tests at Fermilab before shipping them to DESY for installation. The calibrations of the modules used beams of electrons and hadrons, measuring the uniformity of the response, and checking the resolution. The runs also provided opportunity to test a large fraction of the actual ZEUS calorimeter readout system in an integrated beam environment more than one year before HERA turn on. The experiment utilized two computer controlled mechanical structures. one of which was capable of holding up to four modules in order to study shower containment, and a magnetic spectrometer with a high resolution beam tracking system. During two running periods, beams of 6 to 110 GeV containing e, mu, pi, and pBAR were used. The results show energy resolutions of 35%/square-root E for hadrons and 19%/square-root E for electrons, uniformities at the 1% level, energy nonlinearity less than 1%, and equal response for electrons and hadrons.
引用
收藏
页码:23 / 52
页数:30
相关论文
共 24 条
[1]   COSMIC-RAY TESTS OF THE ZEUS BARREL CALORIMETER MODULES [J].
AMBATS, I ;
DAWSON, J ;
DERRICK, M ;
MAGILL, S ;
MUSGRAVE, B ;
REPOND, J ;
SCHLERETH, J ;
STANEK, R ;
SUGANO, K ;
TALAGA, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 320 (1-2) :161-176
[2]   CONSTRUCTION AND BEAM TEST OF THE ZEUS FORWARD AND REAR CALORIMETER [J].
ANDRESEN, A ;
BAMBERGER, A ;
BARGENDE, A ;
BARREIRO, F ;
BEHRENS, U ;
BENTVELSEN, S ;
BRKIC, M ;
BUROW, B ;
CALDWELL, A ;
CASES, G ;
CORRIVEAU, F ;
CRITTENDEN, JA ;
DAKE, A ;
DANNEMANN, A ;
DAWSON, J ;
DIERKS, K ;
DREWS, G ;
ENGELEN, J ;
FAWCETT, H ;
FRISKEN, W ;
FURTJES, A ;
GILKINSON, D ;
HAGGE, L ;
HAMATSU, R ;
HANNA, D ;
HARTMANN, J ;
HASEGAWA, T ;
HASELL, D ;
HAZUMI, M ;
HERVAS, L ;
HILGER, E ;
HOLM, U ;
ISHII, T ;
DEJONG, P ;
KAMMERLOCHER, H ;
KASAI, S ;
KITAMURA, S ;
KLANNER, R ;
KOOIJMAN, P ;
KOTZ, U ;
KRAMER, M ;
KREBS, B ;
KROGER, W ;
KRUGER, J ;
KUZE, M ;
LEVMAN, G ;
LINDENBERG, T ;
MARTIN, J ;
MAYER, J ;
VANDERLUGT, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 309 (1-2) :101-142
[3]   TEST OF THE ZEUS FORWARD CALORIMETER PROTOTYPE [J].
BEHRENS, U ;
CRITTENDEN, J ;
DIERKS, K ;
DREWS, G ;
ENGELEN, J ;
FRISKEN, B ;
HAMATSU, R ;
HANNA, D ;
HOLM, U ;
GARCIA, MA ;
HASELL, D ;
HASEGAWA, T ;
KLANNER, R ;
KOLL, O ;
KOOIJMAN, P ;
KOTZ, U ;
KRAMER, M ;
KRUGER, J ;
LEHMANN, J ;
LEVMAN, G ;
LUKE, D ;
MARTIN, J ;
NEELIN, P ;
ROHDE, M ;
ROS, E ;
SELONKE, F ;
SMITH, G ;
STAIRS, G ;
STRAVER, J ;
TIECKE, H ;
TROCONIZ, JF ;
TSURUGAI, T ;
VOGEL, W ;
WICK, K ;
WULKER, M ;
YOUNGMAN, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 289 (1-2) :115-138
[4]  
BENSTEIN A, 1991, ZEUS91114 NOT
[5]   PERFORMANCE OF A COMPENSATING LEAD SCINTILLATOR HADRONIC CALORIMETER [J].
BERNARDI, E ;
DREWS, G ;
GARCIA, MA ;
KLANNER, R ;
KOTZ, U ;
LEVMAN, G ;
LOMPERSKI, M ;
LUKE, D ;
ROS, E ;
SELONKE, F ;
TIECKE, H ;
TSIROU, M ;
VOGEL, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 262 (2-3) :229-242
[6]  
BOTERENBROOD H, 1992, NUCL INSTRUM METH A, V332, P563
[7]   HADRON SAMPLING CALORIMETRY, A PUZZLE OF PHYSICS [J].
BRUCKMANN, H ;
ANDERS, B ;
BEHRENS, U .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 263 (01) :136-149
[8]  
BRUN R, 1986, CERN DDEE841
[9]   OPTICAL READOUT COMPONENTS FOR THE ZEUS BARREL CALORIMETER [J].
BYLSMA, BG ;
DURKIN, LS ;
FITCH, J ;
LI, C ;
LING, TY ;
MCLEAN, K ;
PARK, SK ;
ROMANOWSKI, TA ;
SEIDLEIN, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 305 (02) :354-365
[10]   DESIGN AND IMPLEMENTATION OF A HIGH-PRECISION READOUT SYSTEM FOR THE ZEUS CALORIMETER [J].
CALDWELL, A ;
GIALAS, I ;
MISHRA, S ;
PARSONS, J ;
RITZ, S ;
SCIULLI, F ;
SIPPACH, W ;
SMITH, W ;
HERVAS, L ;
KOTZ, U ;
KLANNER, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 321 (1-2) :356-364