AUTOMATIC 3-DIMENSIONAL CORRELATION OF CT-CT, CT-MRI, AND CT-SPECT USING CHAMFER MATCHING

被引:177
作者
VANHERK, M
KOOY, HM
机构
[1] Joint Center for Radiation Therapy, Department of Radiation Oncology, Harvard Medical School, Boston, Massachusetts
关键词
IMAGE CORRELATION; CHAMFER MATCHING; RADIOTHERAPY; TREATMENT PLANNING; CT; MRI; SPECT;
D O I
10.1118/1.597344
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Image correlation is often required to utilize the complementary information in CT, MRI, and SPECT. A practical method for automatic image correlation in three-dimensions (3D) based on chamfer matching is described. The method starts with automatic extraction of contour points in one modality and automatic segmentation of the corresponding feature in the other modality. A distance transform is applied to the segmented volume and a cost function is defined that operates between the contour points and the distance transform. Matching is performed by iteratively optimizing the cost function for 3D translation, rotation, and scaling of the contour points. The complete matching process including segmentation requires no user interaction and takes about 100 s on an HP715/50 workstation. Perturbation tests on clinical data with cost functions based on mean, rms, and maximum distances in combination with two general purpose optimization procedures have been performed. The performance of the methods has been quantified in terms of accuracy, capture range, and reliability. The best results on clinical data are obtained with the cost function based on the mean distance and the simplex optimization method. The accuracy is 0.3 mm for CT-Cr, 1.0 mm for CT-MRI, and 0.7 mm for CT-SPECT correlation of the head. The accuracy is usually at subpixel level but is limited by global geometric distortions, e.g., for CT-MRI correlation. Both for CT-CT and CT-MRI correlation the capture range is about 6 cm, which is higher than normal differences in patient setup found on the scanners (less than 4 cm). This means that the correlation procedure seldom fails (better than 98% reliability) and user interaction is unnecessary. For CT-SPECT matching the capture range is about 3 cm (80% reliability), and must be further improved. The method has already been introduced in clinical practice.
引用
收藏
页码:1163 / 1178
页数:16
相关论文
共 27 条
[1]   PROBABLE CAUSES OF RECURRENCE IN PATIENTS WITH CHORDOMA AND CHONDROSARCOMA OF THE BASE OF SKULL AND CERVICAL-SPINE [J].
AUSTIN, JP ;
URIE, MM ;
CARDENOSA, G ;
MUNZENRIDER, JE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (03) :439-444
[2]   HEPATIC HEMANGIOMAS - DIAGNOSIS WITH FUSION OF MR, CT, AND TC-99M-LABELED RED-BLOOD-CELL SPECT IMAGES [J].
BIRNBAUM, BA ;
NOZ, ME ;
CHAPNICK, J ;
SANGER, JJ ;
MEGIBOW, AJ ;
MAGUIRE, GQ ;
WEINREB, JC ;
KAMINER, EM ;
KRAMER, EL .
RADIOLOGY, 1991, 181 (02) :469-474
[3]   DISTANCE TRANSFORMATIONS IN DIGITAL IMAGES [J].
BORGEFORS, G .
COMPUTER VISION GRAPHICS AND IMAGE PROCESSING, 1986, 34 (03) :344-371
[4]  
BRENT RP, 1973, ALGORITHMS MINIMIZAT, pCH7
[5]   OPTIMIZATION AND EVALUATION OF LANDMARK-BASED IMAGE CORRELATION [J].
ENDE, G ;
TREUER, H ;
BOESECKE, R .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (01) :261-271
[6]  
GILHUIJS K, 1991, 5TH P INT C IM AN P
[7]   AUTOMATIC ONLINE INSPECTION OF PATIENT SETUP IN RADIATION-THERAPY USING DIGITAL PORTAL IMAGES [J].
GILHUIJS, KGA ;
VANHERK, M .
MEDICAL PHYSICS, 1993, 20 (03) :667-677
[8]   MULTIMODALITY IMAGE INTEGRATION FOR STEREOTAXIC SURGICAL PLANNING [J].
HENRI, CJ ;
COLLINS, DL ;
PETERS, TM .
MEDICAL PHYSICS, 1991, 18 (02) :167-177
[9]   A GEOMETRIC ALGORITHM FOR MEDICAL IMAGE CORRELATIONS [J].
HOLUPKA, EJ ;
KOOY, HM .
MEDICAL PHYSICS, 1992, 19 (02) :433-438
[10]  
JIANG HJ, 1992, P SOC PHOTO-OPT INS, V1808, P196, DOI 10.1117/12.131078