TEARS OF CRUCIATE LIGAMENTS AND MENISCI - EVALUATION WITH CINE MR IMAGING

被引:32
作者
NIITSU, M [1 ]
ANNO, I [1 ]
FUKUBAYASHI, T [1 ]
SHIMOJO, H [1 ]
KUNO, S [1 ]
AKISADA, M [1 ]
机构
[1] UNIV TSUKUBA,INST CLIN MED,DEPT ORTHOPED,SAKURA,IBARAKI 305,JAPAN
关键词
KNEE; INJURIES; LIGAMENTS AND MENISCI; MR STUDIES; MAGNETIC RESONANCE (MR); CINE STUDY; 3-DIMENSIONAL;
D O I
10.1148/radiology.178.3.1994433
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A cine magnetic resonance (MR) imaging technique, involving the acquisition of kinematic sagittal images during knee movement, was used to evaluate 52 symptomatic knee joints. Results were compared with those obtained by means of static three-dimensional (3D) MR imaging. Twenty-seven of the 28 anterior cruciate ligament (ACL) tears and 22 of 24 normal ligaments were correctly identified at cine MR imaging for a sensitivity of 96% and a specificity of 92%. Static 3D MR imaging yielded a sensitivity of 71% and a specificity of 88%. All four posterior cruciate ligament tears were identified at cine and 3D MR imaging. For meniscal tears, cine MR imaging yielded a sensitivity of 48% and a specificity of 96%; the sensitivity and specificity for 3D MR imaging were 71% and 96%, respectively. Cine MR imaging proved to be more useful than static MR imaging in assessing the tightness of cruciate ligaments, especially of those that were partially torn, and in assessing the movement of meniscal-free fragments. The increased information obtained with cine MR imaging may warrant continued investigation and clinical application.
引用
收藏
页码:859 / 864
页数:6
相关论文
共 50 条
[31]   ANTERIOR CRUCIATE LIGAMENT INJURY - MR IMAGING DIAGNOSIS AND PATTERNS OF INJURY [J].
REMER, EM ;
FITZGERALD, SW ;
FRIEDMAN, H ;
ROGERS, LF ;
HENDRIX, RW ;
SCHAFER, MF .
RADIOGRAPHICS, 1992, 12 (05) :901-915
[32]   ELECTROCARDIOGRAPH-INDEPENDENT, WIRELESS CARDIOVASCULAR CINE MR IMAGING [J].
WHITE, RD ;
PASCHAL, CB ;
CLAMPITT, ME ;
SPRAGGINS, TA ;
LENZ, GW .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (03) :347-355
[33]   EVALUATION OF LEFT-VENTRICULAR VOLUME AND MASS WITH BREATH-HOLD CINE MR-IMAGING [J].
SAKUMA, H ;
FUJITA, N ;
FOO, TKF ;
CAPUTO, GR ;
NELSON, SJ ;
HARTIALA, J ;
SHIMAKAWA, A ;
HIGGINS, CB .
RADIOLOGY, 1993, 188 (02) :377-380
[34]   Cine gradient-echo MR imaging and MR velocity mapping in the evaluation of congenital heart disease [J].
Rebergen, SA ;
Niezen, RA ;
Helbing, WA ;
vanderWall, EE ;
deRoos, A .
RADIOGRAPHICS, 1996, 16 (03) :467-481
[35]   NORMAL AND DIFFUSELY ABNORMAL MYOCARDIUM IN HUMANS - FUNCTIONAL AND METABOLIC CHARACTERIZATION WITH P-31 MR SPECTROSCOPY AND CINE MR IMAGING [J].
AUFFERMANN, W ;
CHEW, WM ;
WOLFE, CL ;
TAVARES, NJ ;
PARMLEY, WW ;
SEMELKA, RC ;
DONNELLY, T ;
CHATTERJEE, K ;
HIGGINS, CB .
RADIOLOGY, 1991, 179 (01) :253-259
[36]   DETERMINATION OF LEFT-VENTRICULAR VOLUME AND MASS WITH USE OF BIPHASIC SPIN-ECHO MR IMAGING - COMPARISON WITH CINE MR [J].
CAPUTO, GR ;
SUZUKI, JI ;
KONDO, C ;
CHO, H ;
QUAIFE, RA ;
HIGGINS, CB ;
PARKER, DL .
RADIOLOGY, 1990, 177 (03) :773-777
[37]   NORMAL LEFT-VENTRICULAR DIMENSIONS AND FUNCTION - INTERSTUDY REPRODUCIBILITY OF MEASUREMENTS WITH CINE MR IMAGING [J].
SEMELKA, RC ;
TOMEI, E ;
WAGNER, S ;
MAYO, J ;
KONDO, C ;
SUZUKI, J ;
CAPUTO, GR ;
HIGGINS, CB .
RADIOLOGY, 1990, 174 (03) :763-768
[38]   Positive Contrast MR Imaging of Tendons, Ligaments, and Menisci by Subtraction of Signals From a Double Echo Steady State Sequence (Sub-DESS) [J].
Martirosian, Petros ;
Schraml, Christina ;
Springer, Fabian ;
Schwenzer, Nina F. ;
Wuerslin, Christian ;
Schick, Fritz ;
Deimling, Michael .
MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (01) :294-301
[39]   Diagnosis of recurrent meniscal tears: Prospective evaluation of conventional MR imaging, indirect MR arthrography, and direct MR arthrography [J].
White, LM ;
Schweitzer, ME ;
Weishaupt, D ;
Kramer, J ;
Davis, A ;
Marks, PH .
RADIOLOGY, 2002, 222 (02) :421-429
[40]   MR evaluation of ventricular function: True fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: Feasibility study [J].
Barkhausen, J ;
Ruehm, SG ;
Goyen, M ;
Buck, T ;
Laub, G ;
Debatin, JF .
RADIOLOGY, 2001, 219 (01) :264-269