EVALUATION OF MULTICOMPONENT FLOW-INJECTION ANALYSIS DATA BY USE OF A PARTIAL LEAST-SQUARES CALIBRATION METHOD

被引:23
|
作者
HERNANDEZ, O [1 ]
JIMENEZ, AI [1 ]
JIMENEZ, F [1 ]
ARIAS, JJ [1 ]
机构
[1] UNIV LA LAGUNA,DEPT ANALYT CHEM FOOD & TOXICOL,E-38204 LA LAGUNA,SPAIN
关键词
FLOW INJECTION; SPECTROPHOTOMETRY; CHEMOMETRICS; COBALT; COPPER; ZINC; CALIBRATION;
D O I
10.1016/0003-2670(95)00118-J
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper reports on the use of a flow-injection analysis technique for the simultaneous spectrophotometric resolution of binary and ternary mixtures with the aid of a multivariate calibration method, and its application to the simultaneous determination of Co(II), Cu(II) and Zn(II) with 2-carboxyl-2-hydroxy-5-sulfoformazylbenze (Zincon) over the concentration range 0.397-1.590, 0.268-1.879 and 0.240-1.612 mu g/ml, respectively. Multicomponent analysis was implemented by using a modified version of the partial least squares program. The influence of various chemical and FIA variables affecting the reaction was evaluated. The proposed method was successfully applied to the determination of cobalt, copper and zinc in synthetic mixtures; copper and zinc in blood serum; and cobalt, copper and zinc in veterinary formulations.
引用
收藏
页码:53 / 61
页数:9
相关论文
共 50 条
  • [31] Determination of ethinylestradiol and gestodene in pharmaceuticals by a partial least-squares and principal component regression multivariate calibration
    Berzas, JJ
    Rodriguez, J
    Gastaneda, G
    ANALYTICAL SCIENCES, 1997, 13 (06) : 1029 - 1032
  • [32] Flow-injection calibration procedures with the use of fully rotary valve
    Koscielniak, P
    Janiszewska, J
    Fang, Z
    CHEMIA ANALITYCZNA, 1996, 41 (01): : 85 - 93
  • [33] Partial least-squares vs. Lanczos bidiagonalization -: I:: analysis of a projection method for multiple regression
    Eldén, L
    COMPUTATIONAL STATISTICS & DATA ANALYSIS, 2004, 46 (01) : 11 - 31
  • [34] Use of classical least squares/partial least squares (CLS/PLS) hybrid algorithm for calibration and calibration maintenance of surface acoustic wave (SAW) devices
    Rivera, D
    Alam, MK
    Yelton, WG
    Staton, AW
    Simonson, RJ
    SENSORS AND ACTUATORS B-CHEMICAL, 2004, 99 (2-3): : 480 - 490
  • [35] APPLICATION OF PARTIAL LEAST-SQUARES REGRESSION TO THE SUITABILITY OF MULTICOMPONENT POLAROGRAPHIC-DETERMINATION OF ORGANOCHLORINE PESTICIDES IN EMULSIFIED MEDIUM
    REVIEJO, AJ
    BUYO, FJ
    PINGARRON, JM
    PERAL, JL
    ELECTROANALYSIS, 1993, 5 (04) : 303 - 309
  • [36] CHARACTERIZATION AND ANALYSIS OF SOILS USING MIDINFRARED PARTIAL LEAST-SQUARES .2. CORRELATIONS WITH SOME LABORATORY DATA
    JANIK, LJ
    SKJEMSTAD, JO
    AUSTRALIAN JOURNAL OF SOIL RESEARCH, 1995, 33 (04): : 637 - 650
  • [37] EVALUATION OF LOPHINE DERIVATIVES AS CHEMILUMINOGENS BY A FLOW-INJECTION METHOD
    NAKASHIMA, K
    YAMASAKI, H
    KURODA, N
    AKIYAMA, S
    ANALYTICA CHIMICA ACTA, 1995, 303 (01) : 103 - 107
  • [38] Boosting partial least-squares discriminant analysis with application to near infrared spectroscopic tea variety discrimination
    Tan, Shi-Miao
    Luo, Rui-Min
    Zhou, Yan-Ping
    Xu, Hui
    Song, Dan-Dan
    Ze, Tan
    Yang, Tian-Ming
    Nie, Yan
    JOURNAL OF CHEMOMETRICS, 2012, 26 (01) : 34 - 39
  • [39] A calibration method for odometry of mobile robots based on the least-squares technique: Theory and experimental validation
    Antonelli, G
    Chiaverini, S
    Fusco, G
    IEEE TRANSACTIONS ON ROBOTICS, 2005, 21 (05) : 994 - 1004
  • [40] Simultaneous determination of mepyramine maleate, lidocaine hydrochloride, and dexpanthenol in pharmaceutical preparations by partial least-squares multivariate calibration
    Aksu, Ö
    Bozdogan, A
    Kunt, G
    ANALYTICAL LETTERS, 2006, 39 (04) : 751 - 761