EVALUATION OF MULTICOMPONENT FLOW-INJECTION ANALYSIS DATA BY USE OF A PARTIAL LEAST-SQUARES CALIBRATION METHOD

被引:23
|
作者
HERNANDEZ, O [1 ]
JIMENEZ, AI [1 ]
JIMENEZ, F [1 ]
ARIAS, JJ [1 ]
机构
[1] UNIV LA LAGUNA,DEPT ANALYT CHEM FOOD & TOXICOL,E-38204 LA LAGUNA,SPAIN
关键词
FLOW INJECTION; SPECTROPHOTOMETRY; CHEMOMETRICS; COBALT; COPPER; ZINC; CALIBRATION;
D O I
10.1016/0003-2670(95)00118-J
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper reports on the use of a flow-injection analysis technique for the simultaneous spectrophotometric resolution of binary and ternary mixtures with the aid of a multivariate calibration method, and its application to the simultaneous determination of Co(II), Cu(II) and Zn(II) with 2-carboxyl-2-hydroxy-5-sulfoformazylbenze (Zincon) over the concentration range 0.397-1.590, 0.268-1.879 and 0.240-1.612 mu g/ml, respectively. Multicomponent analysis was implemented by using a modified version of the partial least squares program. The influence of various chemical and FIA variables affecting the reaction was evaluated. The proposed method was successfully applied to the determination of cobalt, copper and zinc in synthetic mixtures; copper and zinc in blood serum; and cobalt, copper and zinc in veterinary formulations.
引用
收藏
页码:53 / 61
页数:9
相关论文
共 50 条
  • [1] MULTICOMPONENT ANALYSIS OF CONCENTRATED-SOLUTIONS BY FLOW-INJECTION ANALYSIS WITH ZONE SAMPLING AND PARTIAL LEAST-SQUARES RESOLUTION
    BLANCO, M
    COELLO, J
    ITURRIAGA, H
    MASPOCH, S
    REDON, M
    RIBA, J
    ANALYTICA CHIMICA ACTA, 1992, 259 (02) : 219 - 224
  • [2] PARTIAL LEAST-SQUARES RESOLUTION OF MULTIANALYTE FLOW-INJECTION DATA
    MACLAURIN, P
    WORSFOLD, PJ
    NORMAN, P
    CRANE, M
    ANALYST, 1993, 118 (06) : 617 - 622
  • [3] Multicomponent analysis by flow injection using a partial least-squares model. Determination of copper and zinc in serum and metal alloys
    Hernandez, O
    Jimenez, F
    Jimenez, AI
    Arias, JJ
    ANALYST, 1996, 121 (02) : 169 - 172
  • [4] Multicomponent analysis by flow injection using a partial least-squares calibration method. Simultaneous spectrophotometric determination of iron, cobalt and nickel at sub-pmm levels
    Moreno, C
    ManuelVez, MP
    Gomez, I
    GarciaVargas, M
    ANALYST, 1996, 121 (11) : 1609 - 1612
  • [5] Flow-injection chemiluminescence simultaneous determination of cobalt(II) and copper(II) using partial least squares calibration
    Li, BX
    Wang, DM
    Lv, HG
    Zhang, ZJ
    TALANTA, 2006, 69 (01) : 160 - 165
  • [6] Flow-injection simultaneous chemiluminescence determination of ascorbic acid and L-cysteine with partial least squares calibration
    Li, BX
    Wang, DM
    Xu, CL
    Zhang, ZJ
    MICROCHIMICA ACTA, 2005, 149 (3-4) : 205 - 212
  • [7] Big data and partial least-squares prediction
    Cook, R. Dennis
    Forzani, Liliana
    CANADIAN JOURNAL OF STATISTICS-REVUE CANADIENNE DE STATISTIQUE, 2018, 46 (01): : 62 - 78
  • [8] Resolution of Ofloxacin–Ciprofloxacin and Ofloxacin–Norfloxacin Binary Mixtures by Flow-Injection Chemiluminescence in Combination with Partial Least Squares Multivariate Calibration
    J. A. Murillo
    A. Alañón Molina
    A. Muñoz de la Peña
    I. Durán Merás
    A. Jiménez Girón
    Journal of Fluorescence, 2007, 17 : 481 - 491
  • [9] Least-squares calibration method for fringe projection profilometry
    Guo, HW
    He, HT
    Yu, YJ
    Chen, MY
    OPTICAL ENGINEERING, 2005, 44 (03) : 1 - 9
  • [10] PERMEATION TUBES FOR CALIBRATION IN FLOW-INJECTION ANALYSIS
    CHALK, SJ
    TYSON, JF
    OLSON, DC
    ANALYST, 1993, 118 (09) : 1227 - 1231