LONG-TERM ANGIOGRAPHIC AND CLINICAL OUTCOME AFTER IMPLANTATION OF BALLOON-EXPANDABLE STENTS IN AORTOCORONARY SAPHENOUS-VEIN GRAFTS

被引:94
作者
FENTON, SH
FISCHMAN, DL
SAVAGE, MP
SCHATZ, RA
LEON, MB
BAIM, DS
KING, SB
HEUSER, RR
CURRY, RC
RAKE, RC
GOLDBERG, S
机构
[1] THOMAS JEFFERSON UNIV,JEFFERSON MED COLL,DIV CARDIOL,PHILADELPHIA,PA 19107
[2] SCRIPPS CLIN & RES CTR,LA JOLLA,CA
[3] WASHINGTON CARDIOL CTR,WASHINGTON,DC
[4] BETH ISRAEL HOSP,BOSTON,MA 02215
[5] EMORY UNIV,ATLANTA,GA 30322
[6] ARIZONA HEART INST,PHOENIX,AZ
[7] FLORIDA HEART INST,ORLANDO,FL
关键词
D O I
10.1016/0002-9149(94)90545-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Balloon angioplasty of aortocoronary saphenous vein graft lesions is associated with high restenosis and clinical event rates. the goal of this multicenter study was to assess long-term angiographic and clinical outcome of patients electively treated with single Palmaz-Schatz stents in aortocoronary saphenous vein grafts. In 198 patients (209 lesions), elective placement of single Palmaz-Schatz stents was attempted. Angiography was performed at baseline, immediately after stent placement, and at 6-month follow-up. Stent placement was successful in 98.5% of patients. One patient (0.5%) had stent thrombosis. Restenosis occurred in 34% (45 of 133) of the restudied lesions. Restenosis was lower in de novo lesions than in restenotic lesions (22% vs 51%, p <0.001). Ostial lesions had a higher restenosis rate than nonostial lesions (61% vs 28%, p = 0.003). Freedom from death, myocardial infarction, coronary artery bypass surgery, and repeat angioplasty was present in 70% of patients. Eighty-two percent of patients with de novo lesions remained event-free at 1 year, whereas only 55% of patients with prior angioplasty were event-free at 1 year (p <0.001). The use of the Palmaz-Schatz stent for the treatment of focal, de novo, aortocoronary saphenous vein graft lesions is associated with a high procedural success rate, a low angiographic restenosis rate, and low clinical event rates, including the need for repeat revascularization. The results of this study need validation by a prospective randomized trial comparing stent implantation with angioplasty.
引用
收藏
页码:1187 / 1191
页数:5
相关论文
共 27 条
  • [1] ANGIOGRAPHIC AND CLINICAL OUTCOME OF INTRACORONARY STENTING - IMMEDIATE AND LONG-TERM RESULTS FROM A LARGE SINGLE-CENTER EXPERIENCE
    CARROZZA, JP
    KUNTZ, RE
    LEVINE, MJ
    POMERANTZ, RM
    FISHMAN, RF
    MANSOUR, M
    GIBSON, CM
    SENERCHIA, CC
    DIVER, DJ
    SAFIAN, RD
    BAIM, DS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (02) : 328 - 337
  • [2] PERCUTANEOUS TRANS-LUMINAL ANGIOPLASTY OF STENOTIC CORONARY-ARTERY BYPASS GRAFTS - 5 YEARS EXPERIENCE
    COTE, G
    MYLER, RK
    STERTZER, SH
    CLARK, DA
    FISHMANROSEN, J
    MURPHY, M
    SHAW, RE
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (01) : 8 - 17
  • [3] STENTING OF VENOUS BYPASS GRAFTS - A NEW TREATMENT MODALITY FOR PATIENTS WHO ARE POOR CANDIDATES FOR REINTERVENTION
    DESCHEERDER, IK
    STRAUSS, BH
    DEFEYTER, PJ
    BEATT, KJ
    BAUR, LHB
    WIJNS, W
    HEYNDRIX, GR
    SURYAPRANATA, H
    VANDENBRAND, M
    BUIS, B
    SERRUYS, PW
    MOREL, MAM
    VANSWIJNDREGT, EM
    [J]. AMERICAN HEART JOURNAL, 1992, 123 (04) : 1046 - 1054
  • [4] DORROS G, 1984, J THORAC CARDIOV SUR, V87, P17
  • [5] PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY IN PATIENTS WITH PRIOR CORONARY-BYPASS SURGERY
    DOUGLAS, JS
    GRUENTZIG, AR
    KING, SB
    HOLLMAN, J
    ISCHINGER, T
    MEIER, B
    CRAVER, JM
    JONES, EL
    WALLER, JL
    BONE, DK
    GUYTON, R
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1983, 2 (04) : 745 - 754
  • [6] EXCIMER-LASER CORONARY ANGIOPLASTY OF AORTO-OSTIAL STENOSES - RESULTS OF THE EXCIMER-LASER CORONARY ANGIOPLASTY (ELCA) REGISTRY IN THE 1ST 200 PATIENTS
    EIGLER, NL
    WEINSTOCK, B
    DOUGLAS, JS
    GOLDENBERG, T
    HARTZLER, G
    HOLMES, D
    LEON, M
    MARGOLIS, J
    NOBUYOSHI, M
    ONEILL, W
    ROTHBAUM, D
    ROUBIN, G
    UNTEREKER, W
    COWLEY, M
    FORRESTER, J
    LITVACK, F
    [J]. CIRCULATION, 1993, 88 (05) : 2049 - 2057
  • [7] RESTENOSIS AFTER PLACEMENT OF PALMAZ-SCHATZ STENTS IN NATIVE CORONARY-ARTERIES - INITIAL RESULTS OF A MULTICENTER EXPERIENCE
    ELLIS, SG
    SAVAGE, M
    FISCHMAN, D
    BAIM, DS
    LEON, M
    GOLDBERG, S
    HIRSHFELD, JW
    CLEMAN, MW
    TEIRSTEIN, PS
    WALKER, C
    BAILEY, S
    BUCHBINDER, M
    TOPOL, EJ
    SCHATZ, RA
    [J]. CIRCULATION, 1992, 86 (06) : 1836 - 1844
  • [8] EFFECT OF INTRACORONARY STENTING ON INTIMAL DISSECTION AFTER BALLOON ANGIOPLASTY - RESULTS OF QUANTITATIVE AND QUALITATIVE CORONARY ANALYSIS
    FISCHMAN, DL
    SAVAGE, MP
    LEON, MB
    SCHATZ, RA
    ELLIS, SG
    CLEMAN, MW
    TEIRSTEIN, P
    WALKER, CM
    BAILEY, S
    HIRSHFELD, JW
    GOLDBERG, S
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (06) : 1445 - 1451
  • [9] A RANDOMIZED COMPARISON OF CORONARY-STENT PLACEMENT AND BALLOON ANGIOPLASTY IN THE TREATMENT OF CORONARY-ARTERY DISEASE
    FISCHMAN, DL
    LEON, MB
    BAIM, DS
    SCHATZ, RA
    SAVAGE, MP
    PENN, I
    DETRE, K
    VELTRI, L
    RICCI, D
    NOBUYOSHI, M
    CLEMAN, M
    HEUSER, R
    ALMOND, D
    TEIRSTEIN, PS
    FISH, RD
    COLOMBO, A
    BRINKER, J
    MOSES, J
    SHAKNOVICH, A
    HIRSHFELD, J
    BAILEY, S
    ELLIS, S
    RAKE, R
    GOLDBERG, S
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 496 - 501
  • [10] FISCHMAN DL, 1993, ADV QUANTITATIVE COR, P553