BIOMAGNETIC MEASUREMENTS UTILIZING A SUPERPARAMAGNETIC MARKER - A FEASIBILITY STUDY

被引:3
|
作者
MACRI, MA
DELGRATTA, C
DIDONATO, L
DILUZIO, S
ROMANI, GL
DELLAPENNA, S
PASQUARELLI, A
机构
[1] UNIV G DANNUNZIO,IST TECNOL AVANZATE BIOMED,I-66013 CHIETI,ITALY
[2] CNR,IST ELETTRON STATO SOLIDO,I-00156 ROME,ITALY
来源
NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA D-CONDENSED MATTER ATOMIC MOLECULAR AND CHEMICAL PHYSICS FLUIDS PLASMAS BIOPHYSICS | 1994年 / 16卷 / 05期
关键词
D O I
10.1007/BF02463731
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A preliminary study is here reported on a new potential marker for biomagnetic measurements. The marker consists of superparamagnetic polymer microspheres which were detected in the presence of external steady magnetic fields by means of an r.f.-SQUID magnetometer. The particles were prepared in samples differing in the concentration value and immersed in a homogeneous magnetic field of variable intensity. A simple model was taken into account for the distribution of the microspheres in the samples, so that the theoretical values were compared to the marker field values measured by the biomagnetic sensor. The overall sensitivity of the experimental apparatus and the minimum concentration value of the marker were then estimated.
引用
收藏
页码:425 / 432
页数:8
相关论文
共 50 条
  • [1] SQUID BIOMAGNETIC MEASUREMENTS
    FARRELL, DE
    ZANZUCCHI, P
    CRC CRITICAL REVIEWS IN SOLID STATE AND MATERIALS SCIENCES, 1983, 11 (02): : 99 - 122
  • [2] BIOMAGNETIC MEASUREMENTS USING SQUIDS
    ANNINOS, PA
    ANOGIANAKIS, G
    LEHNERTZ, K
    PANTEV, C
    HOKE, M
    INTERNATIONAL JOURNAL OF NEUROSCIENCE, 1987, 37 (3-4) : 149 - 168
  • [3] SENSITIVITY LIMITS IN BIOMAGNETIC MEASUREMENTS
    KATILA, T
    LEINIO, M
    MONTONEN, J
    NENONEN, J
    ACTA OTO-LARYNGOLOGICA, 1991, : 36 - 42
  • [4] Thermal noise in biomagnetic measurements
    Nenonen, J
    Montonen, J
    Katila, T
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (06): : 2397 - 2405
  • [5] MR angiography with superparamagnetic iron oxide: Feasibility study
    Schmitz, SA
    Albrecht, T
    Wolf, KJ
    RADIOLOGY, 1999, 213 (02) : 603 - 607
  • [7] Feasibility study to design a particle deposition unit utilizing electrophoresis for off-line measurements
    Jung Hyeun Kim
    Korean Journal of Chemical Engineering, 2008, 25 : 377 - 382
  • [8] ALUMINUM SHIELDED ROOM FOR BIOMAGNETIC MEASUREMENTS
    STROINK, G
    BLACKFORD, B
    BROWN, B
    HORACEK, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1981, 52 (03): : 463 - 468
  • [9] Biomagnetic measurements using squid instrumentation
    Rassi, D
    Zhuravlev, Y
    MAGNETIC AND SUPERCONDUCTING MATERIALS, (MSM-99), VOLS A AND B, 2000, : 639 - 644
  • [10] Measurements of gastric emptying by biomagnetic techniques
    Vazquez, L. A.
    Sosa, M.
    Cordova, T.
    Vargas, F. M.
    Huerta, M. R.
    MEDICAL PHYSICS, 2006, 854 : 138 - +