Comparison of a Three-Dimensional Numerical Model for Fire Resistance of Axially Loaded Concrete Filled Steel Tubular Columns with Eurocode 4

被引:2
|
作者
Espinos, Ana [1 ]
Ibanez, Carmen [1 ]
Romero, Manuel L. [1 ]
Hospitaler, Antonio [1 ]
机构
[1] Univ Politecn Valencia, Inst Ciencia & Tecnol Hormigon ICITECH, Camino Vera S-N, E-46022 Valencia, Spain
关键词
Fire resistance; Concrete filled tubular column; Finite element analysis; Simple calculation model; Eurocode; 4;
D O I
10.1260/2040-2317.2.2.67
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, the behaviour of slender axially loaded square and circular CFT columns exposed to fire is modelled using the finite element analysis package ABAQUS. A realistic sequentially coupled nonlinear thermal-stress analysis is conducted for a series of columns available in the literature. By means of this model, a comparison between fire resistance simulations results and experimental tests found in literature is made. Similarly, simulations results are compared to the Eurocode 4 simplified calculation model predictions. Comparisons show that whereas Eurocode 4 predictions are very conservative for both circular and square section CFT columns, the results obtained from the developed numerical model are much more realistic.
引用
收藏
页码:67 / 79
页数:13
相关论文
共 50 条
  • [31] Bearing capacity of axially loaded stirrup confined concrete-filled square steel tubular stub columns
    Gong Y.
    Fu L.
    Ding F.
    Yu Z.
    Li G.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2016, 37 : 239 - 244
  • [32] Experimental behaviour of steel connections to concrete filled steel tubular columns in fire
    Wang, Y. C.
    Ding, J.
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2007, 7 (03) : 201 - 208
  • [33] Post-Earthquake Fire Resistance of Circular Concrete-Filled Steel Tubular Columns
    Wang, J. H.
    Kunnath, S.
    He, J.
    Xiao, Y.
    JOURNAL OF STRUCTURAL ENGINEERING, 2020, 146 (06)
  • [34] Study of recycled concrete-filled steel tubular columns on the compressive capacity and fire resistance
    Wang, Haiyang
    Zha, Xiaoxiong
    Liu, Yixiang
    Luo, Chaoning
    Iu, Chi Kin
    ADVANCES IN MECHANICAL ENGINEERING, 2017, 9 (06)
  • [35] Fire performance of concrete filled steel tubular beam-columns
    Han, LH
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2001, 57 (06) : 695 - 709
  • [36] Fire resistance study of axially loaded high strength steel columns
    Wang, Weiyong
    Ohmiya, Yoshifumi
    Ma, Gaofeng
    9TH ASIA-OCEANIA SYMPOSIUM ON FIRE SCIENCE AND TECHNOLOGY, 2013, 62 : 690 - 701
  • [37] Simple design procedure for concrete filled steel tubular columns in fire
    Ukanwa, Kingsley U.
    Clifton, G. Charles
    Lim, James B. P.
    Hicks, Stephen J.
    Sharma, Umesh
    Abu, Anthony
    ENGINEERING STRUCTURES, 2018, 155 : 144 - 156
  • [38] Fire behavior of eccentrically loaded slender high strength concrete-filled tubular columns
    Moliner, V.
    Espinos, A.
    Romero, M. L.
    Hospitaler, A.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2013, 83 : 137 - 146
  • [39] Theoretical and numerical analysis to concrete filled double skin steel tubular columns under fire conditions
    Yao, Yao
    Li, Hao
    Tan, Kanghai
    THIN-WALLED STRUCTURES, 2016, 98 : 547 - 557
  • [40] FE modelling and fire resistance design of concrete filled double skin tubular columns
    Lu, Hui
    Zhao, Xiao-Ling
    Han, Lin-Hai
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (11) : 1733 - 1748