Comparison of a Three-Dimensional Numerical Model for Fire Resistance of Axially Loaded Concrete Filled Steel Tubular Columns with Eurocode 4

被引:2
|
作者
Espinos, Ana [1 ]
Ibanez, Carmen [1 ]
Romero, Manuel L. [1 ]
Hospitaler, Antonio [1 ]
机构
[1] Univ Politecn Valencia, Inst Ciencia & Tecnol Hormigon ICITECH, Camino Vera S-N, E-46022 Valencia, Spain
关键词
Fire resistance; Concrete filled tubular column; Finite element analysis; Simple calculation model; Eurocode; 4;
D O I
10.1260/2040-2317.2.2.67
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, the behaviour of slender axially loaded square and circular CFT columns exposed to fire is modelled using the finite element analysis package ABAQUS. A realistic sequentially coupled nonlinear thermal-stress analysis is conducted for a series of columns available in the literature. By means of this model, a comparison between fire resistance simulations results and experimental tests found in literature is made. Similarly, simulations results are compared to the Eurocode 4 simplified calculation model predictions. Comparisons show that whereas Eurocode 4 predictions are very conservative for both circular and square section CFT columns, the results obtained from the developed numerical model are much more realistic.
引用
收藏
页码:67 / 79
页数:13
相关论文
共 50 条
  • [1] Fire Resistance of Axially Loaded Slender Concrete Filled Steel Tubular Columns Development of a Three-Dimensional Numerical Model and Comparison with Eurocode 4
    Espinos, A.
    Hospitaler, A.
    Romero, M. L.
    ACTA POLYTECHNICA, 2009, 49 (01) : 39 - 43
  • [2] Three-dimensional model of axially loaded slender concrete filled steel tubular columns under fire
    Espinos, Ana
    Hospitaler, Antonio
    Ibanez, Carmen
    Romero, Manuel L.
    STEEL CONCRETE COMPOSITE AND HYBRID STRUCTURES, 2009, : 462 - 467
  • [3] Prediction of the Fire Resistance of Slender Concrete Filled Tubular Columns using a Three-Dimensional Numerical Model
    Espinos, A.
    Romero, M. L.
    Ibanez, C.
    Hospitaler, A.
    PROCEEDINGS OF THE TENTH INTERNATIONAL CONFERENCE ON COMPUTATIONAL STRUCTURES TECHNOLOGY, 2010, 93
  • [4] Fire resistance of axially loaded concrete filled steel tube columns
    Yin, Jing
    Zha, Xiao-xiong
    Li, Long-yuan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2006, 62 (07) : 723 - 729
  • [5] Fiber beam model for fire response simulation of axially loaded concrete filled tubular columns
    Ibanez, Carmen
    Romero, M. L.
    Hospitaler, Antonio
    ENGINEERING STRUCTURES, 2013, 56 : 182 - 193
  • [6] Fire resistance of eccentrically loaded slender concrete-filled steel tubular columns
    Yao, Yao
    Li, Hao
    Guo, Hongcun
    Tan, Kanghai
    THIN-WALLED STRUCTURES, 2016, 106 : 102 - 112
  • [7] Fire behavior of axially loaded slender high strength concrete-filled tubular columns
    Romero, Manuel L.
    Moliner, V.
    Espinos, A.
    Ibanez, C.
    Hospitaler, A.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (12) : 1953 - 1965
  • [8] A COMPARISON OF THE DESIGN CODES FOR THE FIRE RESISTANCE OF CONCRETE FILLED STEEL TUBULAR (CFST) COLUMNS
    Chen Feng
    Han Linhai
    Yu Hongxia
    PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON INSPECTION APPRAISAL REPAIRS AND MAINTENANCE OF STRUCTURES, VOLS 1 AND 2, 2010, : 137 - 142
  • [9] Advanced model for predicting the fire response of concrete filled tubular columns
    Espinos, Ana
    Romero, Manuel L.
    Hospitaler, Antonio
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (8-9) : 1030 - 1046
  • [10] Simple calculation model for evaluating the fire resistance of unreinforced concrete filled tubular columns
    Espinos, Ana
    Romero, Manuel L.
    Hospitaler, Antonio
    ENGINEERING STRUCTURES, 2012, 42 : 231 - 244