TRANSPLANTATION OF HEARTS AFTER ARREST AND RESUSCITATION - EARLY AND LONG-TERM RESULTS

被引:30
作者
DEBEGONA, JA [1 ]
GUNDRY, SR [1 ]
RAZZOUK, AJ [1 ]
BOUCEK, MM [1 ]
KAWAUCHI, M [1 ]
BAILEY, LL [1 ]
机构
[1] LOMA LINDA UNIV,SCH MED,MED CTR,DEPT SURG,DIV CARDIOTHORAC SURG,11234 ANDERSON ST,LOMA LINDA,CA 92354
关键词
D O I
10.1016/S0022-5223(19)33999-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transplant surgeons are reluctant to use hearts that have undergone cardiopulmonary resuscitation for cardiac arrest because of the fear of poor early and late cardiac function. A policy of minimizing contraindications to use of donor hearts has led to the unique opportunity of assessing the effects Of donor arrest and successful cardiopulmonary resuscitation on early and late cardiac function in pediatric heart transplantation. A number of 140 infants and children undergoing transplantation from birth to 17 years of age were studied retrospectively and divided into two groups on the basis of cardiopulmonary resuscitation status. Group 1 (72 patients) received donor hearts that were not subjected to cardiopulmonary resuscitation; group 2 (68 patients) received donor hearts that had cardiopulmonary resuscitation for a mean of 18.8 +/- 14.6 minutes, the longest period of time being 60 minutes. Mean ischemic times were almost identical in the two groups: 4.43 +/- 2.0 hours (cardiopulmonary resuscitation) versus 4.5 +/- 2.1 hours (no cardiopulmonary resuscitation). Early cardiac function was assessed on the basis of the number of days the recipient was supported by the ventilator, days receiving dopamine, days receiving isoproterenol, and the amount of inotropic agents required after the operation. The groups did not differ. Parameters of systolic function included fractional shortening, posterior wall thickening, and maximum velocity of change in left ventricular posterior wall dimension during systole. Diastolic function was measured on the basis of left ventricular end-diastolic volume, left ventricular mass, and maximum velocity of change in left ventricular posterior wall dimension during diastole. Both systolic and diastolic function were measured and analyzed from M-mode echocardiography at 1 week, 1 month, 6 months, 1 year, and 2 years after die operation. There were no statistically significant differences in graft function between the two groups m any Of the echocardiographic parameters studied, even at 2 years. No group differed from ranges of normal. Our results suggest that hearts undergoing cardiopulmonary resuscitation for periods of up to 6 minutes can be used safely without evidence of deterioration of early or late cardiac function.
引用
收藏
页码:1196 / 1201
页数:6
相关论文
共 21 条
  • [1] BAILEY L, 1986, J THORAC CARDIOV SUR, V92, P1
  • [2] BAKER JE, 1988, J THORAC CARDIOV SUR, V96, P717
  • [3] CARDIAC TRANSPLANTATION IN INFANCY - DONORS AND RECIPIENTS
    BOUCEK, MM
    KANAKRIYEH, MS
    MATHIS, CM
    TRIMM, RF
    BAILEY, LL
    [J]. JOURNAL OF PEDIATRICS, 1990, 116 (02) : 171 - 176
  • [4] BOVE EL, 1986, J THORAC CARDIOV SUR, V91, P115
  • [5] CHIU RCJ, 1987, CIRCULATION, V76, P146
  • [6] GRICE WN, 1987, CIRCULATION, V76, P150
  • [7] GRIEPP RB, 1971, SURG GYNECOL OBSTETR, V133, P792
  • [8] DEFINING THE LIMITS OF SUITABILITY OF CARDIAC ALLOGRAFTS
    GUERRATY, A
    WECHSLER, AS
    [J]. ANNALS OF THORACIC SURGERY, 1990, 50 (01) : 1 - 2
  • [9] GUNDRY S R, 1990, Journal of the American College of Cardiology, V15, p224A
  • [10] SUCCESSFUL TRANSPLANTATION OF HEARTS HARVESTED 30 MINUTES AFTER DEATH FROM EXSANGUINATION
    GUNDRY, SR
    DEBEGONA, JA
    KAWAUCHI, M
    BAILEY, LL
    [J]. ANNALS OF THORACIC SURGERY, 1992, 53 (05) : 772 - 775