COMPUTER-SIMULATED LUNG NODULES IN DIGITAL CHEST RADIOGRAPHS FOR DETECTION STUDIES

被引:15
作者
YOCKY, DA [1 ]
SEELEY, GW [1 ]
OVITT, TW [1 ]
ROEHRIG, H [1 ]
DALLAS, WJ [1 ]
机构
[1] UNIV ARIZONA,CTR OPT SCI,TUCSON,AZ 85724
关键词
Computer simulation; Digital chest radiography; Lung nodules;
D O I
10.1097/00004424-199008000-00006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Computer simulations of lung nodules overcome many shortcomings of creating radiographs using anthropomorphic nodule phantoms for lung nodule detection studies, but these algorithms can be cumbersome and involved. A simple, fast, and flexible computer program to simulate lung nodules in digital chest radiographs for detection studies is reported. To verify the realism of the simulated nodules, a psychophysical study and a statistical study were conducted. In the psychophysical study, six radiologists and four nonradiologists were asked to distinguish between 17 real lung nodules and 17 computersimulated lung nodules shown in eight radiographs. The results show that the computer-simulated lung nodules are indistinguishable visually from real lung nodules. Using parameters from the Rose model of vision, results show that the simulated and real nodules are the same statistically. Thus, besides visual validity, statistical analysis in confirming the validity of the simulated lung nodules is included. © Lippincott-Raven Publishers.
引用
收藏
页码:902 / 907
页数:6
相关论文
共 19 条
[1]   DIGITAL AND CONVENTIONAL CHEST IMAGING - A MODIFIED ROC STUDY OF OBSERVER PERFORMANCE USING SIMULATED NODULES [J].
CHAKRABORTY, DP ;
BREATNACH, ES ;
YESTER, MV ;
SOTO, B ;
BARNES, GT ;
FRASER, RG .
RADIOLOGY, 1986, 158 (01) :35-39
[2]   EFFECT OF KILOVOLTAGE ON DETECTABILITY OF PULMONARY NODULES IN A CHEST PHANTOM [J].
CHRISTENSEN, EE ;
DIETZ, GW ;
MURRY, RC ;
MOORE, JG ;
STOKELY, EM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1977, 128 (05) :789-793
[3]  
DEGROOT JH, 1971, 24TH P ANN C ENG MED, P286
[4]   THE EFFECT OF VARYING SPATIAL-RESOLUTION ON THE DETECTABILITY OF DIFFUSE PULMONARY NODULES - ASSESSMENT WITH DIGITIZED CONVENTIONAL RADIOGRAPHS [J].
FOLEY, WD ;
WILSON, CR ;
KEYES, GS ;
DIBIANCA, FA ;
SCANLON, GT ;
SCHLEUTER, D ;
LAWSON, TL .
RADIOLOGY, 1981, 141 (01) :25-31
[5]   IMAGE FEATURE ANALYSIS AND COMPUTER-AIDED DIAGNOSIS IN DIGITAL RADIOGRAPHY .3. AUTOMATED DETECTION OF NODULES IN PERIPHERAL LUNG FIELDS [J].
GIGER, ML ;
DOI, K ;
MACMAHON, H .
MEDICAL PHYSICS, 1988, 15 (02) :158-166
[6]   RADIOGRAPHIC APPLICATIONS OF SIGNAL DETECTION THEORY [J].
GOODENOUGH, DJ ;
ROSSMANN, K ;
LUSTED, LB .
RADIOLOGY, 1972, 105 (01) :199-+
[7]   RADIOGRAPHIC APPLICATIONS OF RECEIVER OPERATING CHARACTERISTIC (ROC) CURVES [J].
GOODENOUGH, DJ ;
ROSSMANN, K ;
LUSTED, LB .
RADIOLOGY, 1974, 110 (01) :89-95
[8]   DETECTION ACCURACY IN CHEST RADIOGRAPHY [J].
GRAY, JE ;
TAYLOR, KW ;
HOBBS, BB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1978, 131 (02) :247-253
[9]   DUAL-ENERGY DIGITAL RADIOGRAPHIC QUANTIFICATION OF CALCIUM IN SIMULATED PULMONARY NODULES [J].
HICKEY, NM ;
NIKLASON, LT ;
SABBAGH, E ;
FRASER, RG ;
BARNES, GT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (01) :19-24
[10]   NODULE DETECTION WITH AND WITHOUT A CHEST IMAGE [J].
KUNDEL, HL ;
NODINE, CF ;
THICKMAN, D ;
CARMODY, D ;
TOTO, L .
INVESTIGATIVE RADIOLOGY, 1985, 20 (01) :94-99