MINIATURIZED LIGHT-SCATTERING DETECTOR FOR PACKED CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY

被引:20
作者
DEMIRBUKER, M [1 ]
ANDERSON, PE [1 ]
BLOMBERG, LG [1 ]
机构
[1] UNIV STOCKHOLM,DEPT ANALYT CHEM,ARRHENIUS LAB NAT SCI,S-10691 STOCKHOLM,SWEDEN
关键词
LIGHT SCATTERING DETECTION; SUPERCRITICAL FLUID CHROMATOGRAPHY; PACKED MICROCOLUMNS; ARGENTATION CHROMATOGRAPHY; TRIACYLGLYCEROLS;
D O I
10.1002/mcs.1220050209
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Packed capillary columns provide excellent separation of neutral lipids by supercritical fluid chromatography. For these separations, it is necessary to add a polar modifier to the mobile phase; hitherto, a detector suitable for quantitative analysis has been lacking. For this purpose, a miniaturized evaporative light scattering detector for combination with packed microcolumns in supercritical fluid chromatography has been developed. Since the detector response is dependent on the mobile phase flow rate, a drop in response was found at flow rates above 16 mL min-1 of expanded mobile phase. However, below this flow rate, there was a region of relatively constant response. In this region, quantitative analysis could also be successfully performed when the pressure and/or the temperature of the separation were programmed. The detection limit was lower than 6 ng. With pressure programming, the relative standard deviation in peak area was less than 4%. Minor peaks gave higher RSD values. Further, it is demonstrated that argentation SFC of triacylglycerols provides separation according to chain length as well as to the degree of unsaturation.
引用
收藏
页码:141 / 147
页数:7
相关论文
共 28 条
[1]   COMPARISON OF ETHOXYLATED ALCOHOLS AND POLYETHYLENE GLYCOLS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND SUPERCRITICAL FLUID CHROMATOGRAPHY USING EVAPORATIVE LIGHT-SCATTERING DETECTION [J].
BROSSARD, S ;
LAFOSSE, M ;
DREUX, M .
JOURNAL OF CHROMATOGRAPHY, 1992, 591 (1-2) :149-157
[2]   ANALYSIS OF SYNTHETIC MIXTURES OF WAXES BY SUPERCRITICAL FLUID CHROMATOGRAPHY WITH PACKED-COLUMNS USING EVAPORATIVE LIGHT-SCATTERING DETECTION [J].
BROSSARD, S ;
LAFOSSE, M ;
DREUX, M .
JOURNAL OF CHROMATOGRAPHY, 1992, 623 (02) :323-328
[3]   SUPERCRITICAL FLUID CHROMATOGRAPHY LIGHT-SCATTERING DETECTOR - A PROMISING COUPLING FOR POLAR COMPOUNDS ANALYSIS WITH PACKED-COLUMNS [J].
CARRAUD, P ;
THIEBAUT, D ;
CAUDE, M ;
ROSSET, R ;
LAFOSSE, M ;
DREUX, M .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1987, 25 (09) :395-398
[4]   EVAPORATIVE ANALYZER AS A MASS DETECTOR FOR LIQUID-CHROMATOGRAPHY [J].
CHARLESWORTH, JM .
ANALYTICAL CHEMISTRY, 1978, 50 (11) :1414-1420
[5]   SEPARATION OF MOLECULAR-SPECIES OF TRIACYLGLYCEROLS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH A SILVER ION COLUMN [J].
CHRISTIE, WW .
JOURNAL OF CHROMATOGRAPHY, 1988, 454 :273-284
[6]  
COCKS S, 1991, Analytical Proceedings, V28, P11
[7]   SEPARATION OF UNSATURATED FATTY-ACID METHYL-ESTERS BY PACKED CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY - COMPARISON OF DIFFERENT COLUMN PACKINGS [J].
DEMIRBUKER, M ;
HAGGLUND, I ;
BLOMBERG, LG .
JOURNAL OF CHROMATOGRAPHY, 1992, 605 (02) :263-267
[8]   SEPARATION OF TRIACYLGLYCEROLS BY SUPERCRITICAL-FLUID ARGENTATION CHROMATOGRAPHY [J].
DEMIRBUKER, M ;
BLOMBERG, LG .
JOURNAL OF CHROMATOGRAPHY, 1991, 550 (1-2) :765-774
[9]  
GORNER T, 1989, LC GC-MAG SEP SCI, V7, P502
[10]  
GREIBROKK T, 1989, PROG HPLC, V4, P53