MAGNETIC-RESONANCE IMAGING - EFFECTS OF MAGNETIC-FIELD STRENGTH

被引:82
|
作者
CROOKS, LE
ARAKAWA, M
HOENNINGER, J
MCCARTEN, B
WATTS, J
KAUFMAN, L
机构
[1] RADIOL IMAGING LAB, 400 GRANDVIEW DR, S SAN FRANCISCO, CA 94080 USA
[2] UNIV CALIF SAN FRANCISCO, SAN FRANCISCO, CA 94143 USA
关键词
D O I
10.1148/radiology.151.1.6701302
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance images of the head, abdomen and pelvis of normal adult men were obtained using varying magnetic field strength. Measurements of T1 and T2 relaxations and of signal-noise (SN) ratios were also determined. The T1 relaxation of gray matter, white matter and muscle increases and T2 decreases with field stremgth, while T1 of fat remains relatively constant and T2 increases. As a consequence, for any 1 spin echo sequence, gray/white matter contrast decreases and muscle/fat contrast increases with field. SN levels rise rapidly up to 3.0 kgauss and then change more slowly, actually dropping for muscle. The optimum field for magnetic resonance imaging depends on tissue type, body part and imaging sequence, so that it does not have a unique value. Magnetic resonance systems that operate in the 3.0-5.0 kgauss range achieve most or all of the gains that can be achieved by higher magnetic fields.
引用
收藏
页码:127 / 133
页数:7
相关论文
共 50 条
  • [21] MAGNETIC-RESONANCE IMAGING
    不详
    SOUTH AFRICAN MEDICAL JOURNAL, 1985, 67 (02): : 38 - 38
  • [22] MAGNETIC-RESONANCE IMAGING
    MYERS, CP
    FISHER, JK
    TEXAS JOURNAL OF SCIENCE, 1988, 40 (02): : 225 - 240
  • [23] MAGNETIC-RESONANCE IMAGING
    CZYGAN, P
    BIOMEDIZINISCHE TECHNIK, 1984, 29 (10): : 246 - 253
  • [24] MAGNETIC-RESONANCE IMAGING
    KEAN, DM
    BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (692): : 796 - 796
  • [25] MAGNETIC-RESONANCE IMAGING
    KOEHLER, RE
    ALABAMA JOURNAL OF MEDICAL SCIENCES, 1985, 22 (02): : 141 - 143
  • [26] MAGNETIC-RESONANCE IMAGING
    ANDREW, ER
    HOCH, MJR
    SOUTH AFRICAN JOURNAL OF SCIENCE, 1980, 76 (06) : 256 - 258
  • [27] MAGNETIC-RESONANCE IMAGING
    BERNSTEIN, MJ
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1988, 259 (14): : 2132 - 2138
  • [28] MAGNETIC-RESONANCE IMAGING
    HIGGINS, CB
    WESTERN JOURNAL OF MEDICINE, 1985, 143 (03): : 376 - 377
  • [29] MAGNETIC-FIELD EFFECTS ON RESONANCE-ABSORPTION
    OOSUGA, T
    TAKABE, H
    MIMA, K
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1985, 54 (11) : 4178 - 4187
  • [30] MAGNETIC-RESONANCE IMAGING OF COARCTATION OF THE AORTA IN INFANTS - USE OF A HIGH-FIELD STRENGTH
    BAKER, EJ
    AYTON, V
    SMITH, MA
    PARSONS, JM
    MAISEY, MN
    LADUSANS, EJ
    ANDERSON, RH
    TYNAN, M
    YATES, AK
    DEVERALL, PB
    BRITISH HEART JOURNAL, 1989, 62 (02): : 97 - 101