MAGNETIC-RESONANCE IMAGING - EFFECTS OF MAGNETIC-FIELD STRENGTH

被引:82
|
作者
CROOKS, LE
ARAKAWA, M
HOENNINGER, J
MCCARTEN, B
WATTS, J
KAUFMAN, L
机构
[1] RADIOL IMAGING LAB, 400 GRANDVIEW DR, S SAN FRANCISCO, CA 94080 USA
[2] UNIV CALIF SAN FRANCISCO, SAN FRANCISCO, CA 94143 USA
关键词
D O I
10.1148/radiology.151.1.6701302
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance images of the head, abdomen and pelvis of normal adult men were obtained using varying magnetic field strength. Measurements of T1 and T2 relaxations and of signal-noise (SN) ratios were also determined. The T1 relaxation of gray matter, white matter and muscle increases and T2 decreases with field stremgth, while T1 of fat remains relatively constant and T2 increases. As a consequence, for any 1 spin echo sequence, gray/white matter contrast decreases and muscle/fat contrast increases with field. SN levels rise rapidly up to 3.0 kgauss and then change more slowly, actually dropping for muscle. The optimum field for magnetic resonance imaging depends on tissue type, body part and imaging sequence, so that it does not have a unique value. Magnetic resonance systems that operate in the 3.0-5.0 kgauss range achieve most or all of the gains that can be achieved by higher magnetic fields.
引用
收藏
页码:127 / 133
页数:7
相关论文
共 50 条
  • [1] MAGNETIC-FIELD STABILITY ISSUES IN MAGNETIC-RESONANCE IMAGING
    SPENCER, CM
    HUNG, DT
    PERLMUTTER, RJ
    WILFLEY, BP
    IEEE TRANSACTIONS ON MAGNETICS, 1988, 24 (02) : 1276 - 1279
  • [2] THE EFFECT OF STATIC MAGNETIC-FIELD STRENGTH ON TISSUE DIFFERENTIATION IN MAGNETIC-RESONANCE IMAGING (MRI)
    LUYPAERT, R
    GOES, E
    OSTEAUX, M
    RAEYMAEKERS, H
    BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (692): : 816 - 817
  • [3] NUCLEAR MAGNETIC-RESONANCE IMAGING - CONTRAST-TO-NOISE RATIO AS A FUNCTION OF STRENGTH OF MAGNETIC-FIELD
    HART, HR
    BOTTOMLEY, PA
    EDELSTEIN, WA
    KARR, SG
    LEUE, WM
    MUELLER, O
    REDINGTON, RW
    SCHENCK, JF
    SMITH, LS
    VATIS, D
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 141 (06) : 1195 - 1201
  • [4] MAGNETIC-FIELD STRENGTH ISSUES IN MAGNETIC-RESONANCE-IMAGING
    MARSHALL, D
    HAILEY, D
    MENON, D
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1994, 45 (03): : 180 - 184
  • [5] NUCLEAR MAGNETIC-RESONANCE IN NONHOMOGENEOUS MAGNETIC-FIELD
    AKULOV, NS
    VENGRINO.VL
    NOVIKOV, SA
    DOKLADY AKADEMII NAUK BELARUSI, 1973, 17 (03): : 211 - 214
  • [6] MEASUREMENT OF SURFACE MAGNETIC-FIELD OF SUPERCONDUCTOR BY MAGNETIC-RESONANCE
    MANIWA, Y
    SATO, H
    MIZOGUCHI, K
    KUME, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1990, 29 (02): : 268 - 269
  • [7] REGULATION OF GUIDING MAGNETIC-FIELD IN NUCLEAR MAGNETIC-RESONANCE
    VIBET, C
    COMPTES RENDUS HEBDOMADAIRES DES SEANCES DE L ACADEMIE DES SCIENCES SERIE B, 1974, 279 (07): : 171 - 173
  • [8] MAGNETIC-RESONANCE IMAGING OF THE BREAST AT HIGH-FIELD STRENGTH
    HERON, CW
    WILLIAMS, MP
    CHERRYMAN, GR
    HUSBAND, JE
    BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (728): : 762 - 762
  • [9] GENERAL-THEORY OF MAGNETIC-RESONANCE IN A PERIODICAL MAGNETIC-FIELD - MAGNETIC-RESONANCE IN DEGENERATE QUASIENERGY STATES
    ANOSOV, MD
    OPTIKA I SPEKTROSKOPIYA, 1983, 55 (05): : 899 - 903
  • [10] MAGNETIC-FIELD STABILIZER FOR NUCLEAR MAGNETIC-RESONANCE PULSE SPECTROMETERS
    EROFEEV, LN
    TARASOV, VP
    SHUMM, BA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1981, 24 (03) : 709 - 711