VIRUS REMOVAL BY ACTIVATED-SLUDGE TREATMENT

被引:6
作者
SHIMOHARA, E [1 ]
SUGISHIMA, S [1 ]
KANEKO, M [1 ]
机构
[1] SETSUNAN UNIV,NEYAGAWA,OSAKA 572,JAPAN
关键词
Viruses;
D O I
10.2166/wst.1985.0105
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Removal of poliovirus 1 by activated sludge treatment in batch experiments was investigated. Virus counts were reduced by more than 99% under conditions of 0. 2 to 0. 4 kg BOD multiplied by (times) kg MLSS** minus **1 multiplied by (times) day** minus **1 and MLSS (mixed liquor suspended solids) concentrations of 1000 to 2000 mg multiplied by (times) 1** minus **1. There were no distinct relationships between BOD-SS loadings or total organic carbon of the effluent and virus inactivation rates. MLSS levels of more than 800 mg multiplied by (times) 1** minus **1 were necessary for more than 99% reduction in viral counts. although MLSS levels of more than 2000 mg multiplied by (times) 1** minus **1 reduced viral counts by 4 log values, factors such as low temperatures and anaerobic conditions which adversely affect the efficiency of activated sludge processes, resulted in prolonged virus survival.
引用
收藏
页码:153 / 158
页数:6
相关论文
共 5 条
[1]  
BERG G, 1973, B WORLD HEALTH ORGAN, V49, P451
[2]   REMOVAL OF ENTERIC VIRUSES FROM SEWAGE BY ACTIVATED-SLUDGE TREATMENT [J].
CLARKE, NA ;
CHANG, SL ;
KABLER, PW ;
STEVENSON, RE .
AMERICAN JOURNAL OF PUBLIC HEALTH AND THE NATIONS HEALTH, 1961, 51 (08) :1118-&
[3]  
GRINSTEIN S, 1970, B WORLD HEALTH ORGAN, V42, P291
[4]  
PIKE EB, 1971, MICROBIAL ASPECTS PO, P123
[5]  
RAO VC, 1977, PROG WATER TECHNOL, V9, P113