A SINGLE-WIRE PROPORTIONAL COUNTER WITH DELAY-LINE POSITION READOUT FOR THE FOCAL PLANE OF A MAGNETIC SPECTROGRAPH

被引:9
|
作者
KOIDE, K [1 ]
NUEVO, AB [1 ]
TAKAI, H [1 ]
MARECHAL, B [1 ]
DIETZSCH, O [1 ]
机构
[1] UNIV FED RIO DE JANEIRO,INST FIS,RIO DE JANEIRO,RJ,BRAZIL
来源
关键词
D O I
10.1016/0167-5087(83)91306-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
引用
收藏
页码:177 / 182
页数:6
相关论文
共 50 条
  • [31] 2-DIMENSIONAL READOUT OF A MULTIWIRE PROPORTIONAL CHAMBER USING A HELICAL DELAY-LINE
    SITAR, B
    STUBBS, RJ
    BREARE, JM
    NUCLEAR INSTRUMENTS & METHODS, 1976, 134 (02): : 267 - 270
  • [32] CHARACTERISTICS OF A SINGLE-WIRE PROPORTIONAL COUNTER WITH VERY THIN RECTANGULAR CROSS-SECTION
    KAGEYAMA, K
    HAYASHIBE, S
    KANAZAWA, M
    WATANABE, H
    FUJIOKA, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 342 (2-3): : 509 - 515
  • [33] INVESTIGATION OF THE CHARACTERISTICS OF A SPHERICAL SINGLE-WIRE PROPORTIONAL COUNTER USED FOR EXPERIMENTAL MICRODOSIMETRY.
    Waker, Anthony J.
    Nuclear instruments and methods in physics research, 1986, A243 (2-3): : 561 - 566
  • [34] MULTI-ANODE RESISTIVE WIRE PROPORTIONAL COUNTER AS A FOCAL PLANE DETECTOR
    IWATANI, K
    YOKOMIZO, H
    TANAKA, M
    KATO, S
    HASEGAWA, T
    HASAI, H
    NISHIYAMA, F
    NUCLEAR INSTRUMENTS & METHODS, 1980, 171 (01): : 61 - 66
  • [35] A POSITION-SENSITIVE MICROCHANNELPLATE DETECTOR USING A DELAY-LINE READOUT ANODE
    KELLER, H
    KLINGELHOFER, G
    KANKELEIT, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 258 (02): : 221 - 224
  • [36] Delay line readout of a large dimension multi-wire proportional chamber
    黎先利
    张云龙
    钱浩
    许咨宗
    汪晓莲
    中国物理C, 2012, 36 (06) : 519 - 524
  • [37] Delay line readout of a large dimension multi-wire proportional chamber
    Li Xian-Li
    Zhang Yun-Long
    Qian Hao
    Xu Zi-Zong
    Wang Xiao-Lian
    CHINESE PHYSICS C, 2012, 36 (06) : 519 - 524
  • [38] A FEASIBILITY STUDY ON A MULTIWIRE GAS PROPORTIONAL COUNTER USING A 28 NS DELAY-LINE
    JONES, AO
    PARKER, BT
    CLIFFORD, P
    FORE, NS
    HALL, C
    HELSBY, WI
    LEWIS, RA
    SHELDON, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3): : 264 - 268
  • [39] CHARACTERISTICS OF MULTIWIRE PROPORTIONAL-COUNTERS WITH DELAY-LINE READOUT FOR MINIMUM-IONIZING PARTICLES
    STETZ, AW
    PEREZMEN.V
    GEAGA, J
    SPINKA, H
    NUCLEAR INSTRUMENTS & METHODS, 1974, 120 (01): : 17 - 22
  • [40] DELAY-LINE READOUT TECHNIQUE APPLIED TO PROPORTIONAL CHAMBERS USING ELECTRONEGATIVE GAS-MIXTURES
    LECOMTE, P
    PEREZMENDEZ, V
    STOKER, G
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1976, 23 (01) : 279 - 280