HEMODYNAMIC-EFFECTS OF COMBINED GENERAL AND EPIDURAL-ANESTHESIA DURING INDUCTION OF ANESTHESIA IN GERIATRIC-PATIENTS

被引:0
|
作者
LESSIRE, H
PFISTERER, M
SCHWEPPEHARTENAUER, ML
PUCHSTEIN, C
机构
[1] RUHR UNIV BOCHUM, KLIN, MARIENHOSP HERNE, ANAESTHESIOL & OPERAT INTENS MED KLIN, W-4630 BOCHUM, GERMANY
[2] SANKT JOSEF STIFT, ANAESTHESIOL ABT, SENDENHORST, GERMANY
来源
ANAESTHESIST | 1991年 / 40卷 / 07期
关键词
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
For major operative procedures in the lower abdomen and many orthopedic procedures such as total hip replacement, a combination of general and epidural anesthesia is used. In order to investigate the hemodynamic effects of such a combination in 14 geriatric patients aged 63-80 years who were undergoing total hip replacement, cardiovascular monitoring was established by an arterial line and a pulmonary artery catheter. The epidural anesthesia was achieved with bupivacaine 0.5% in a dose calculated to obtain a block up to Th 6. General anesthesia was then induced and maintained with midazolam, fentanyl, pancuronium bromide, and a 2:1 nitrous oxide-oxygen mixture. Hemodynamic measurements were established before and 30 min after induction of the epidural anesthesia and 20 min after the induction of general anesthesia. After bupivacaine was injected the loss of sympathetic tone produced a systolic arterial blood pressure decrease from 174 +/- 22 to 136 +/- 28 mmHg (p < 0.05) and a decrease in heart rate from 73 +/- 12 to 66 +/- 10 min-1 (p < 0.05). The cardiac index did not change, but the peripheral vascular resistance decreased significantly. Because intravenous fluids were given simultaneously, preload could be maintained. Oxygen delivery and oxygen extraction did not change. During general anesthesia a significant drop in cardiac output was observed from 3.0 +/- 0.6 1/min.m2 to 2.3 +/- 0.4 1/min.m2 (p < 0.05). The systolic arterial blood pressure decreased to as low as 95 +/- 17 mmHg (p < 0.05) and oxygen delivery decreased from 500 +/- 125 ml/min.m2 to 323 +/- 84 ml/min.m2 (p < 0.05). As a sign of decreased organ perfusion, oxygen extraction changed significantly from 22.7 +/- 4 to 26.8 +/- 7%. From the measurements obtained in this investigation, it may be concluded that a combination of general and epidural anesthesia could lead to significant cardiovascular instability and cardiac depression, and therefore should be used with caution in the high-risk patient.
引用
收藏
页码:375 / 379
页数:5
相关论文
共 50 条
  • [11] A COMPARISON OF EPIDURAL-ANESTHESIA, GENERAL-ANESTHESIA, AND COMBINED EPIDURAL GENERAL-ANESTHESIA FOR RADICAL PROSTATECTOMY
    MALHOTRA, V
    STOUT, R
    GIRARDI, SC
    ANESTHESIOLOGY, 1994, 81 (3A) : A973 - A973
  • [12] Hemodynamic effects of phenylephrine on hypotension during combined general and epidural anesthesia
    Murata, Yuriko
    Tanaka, Yasunori
    Nishiike, Satoshi
    Ogawa, Masao
    Tsuchida, Hideaki
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 : 61 - 62
  • [13] HEMODYNAMIC-EFFECTS OF THORACIC EPIDURAL-ANESTHESIA DURING PROXIMAL AORTIC CROSS-CLAMPING IN PIGS
    AADAHL, P
    SAETHER, OD
    STENSETH, R
    MYHRE, HO
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1995, 39 (01) : 23 - 27
  • [14] HEMODYNAMIC-EFFECTS AND CHARACTERISTICS OF MIDAZOLAM DURING INDUCTION OF ANESTHESIA
    MULLER, H
    SCHLEUSSNER, E
    STOYANOV, M
    KLING, D
    HEMPELMANN, G
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 1981, 31-2 (12A): : 2227 - 2232
  • [15] COMBINED GENERAL EXTRA SUBDURAL ANESTHESIA VS GENERAL EPIDURAL-ANESTHESIA FOR INTRAABDOMINAL SURGERY
    SAVOJA, G
    SANSONE, A
    GULOTTA, G
    PAPA, G
    PIAZZA, F
    MULARO, A
    BRITISH JOURNAL OF ANAESTHESIA, 1995, 74 : 79 - 79
  • [16] COMBINED SPINAL EPIDURAL-ANESTHESIA
    VANDERMEERSCH, E
    BAILLIERES CLINICAL ANAESTHESIOLOGY, 1993, 7 (03): : 691 - 708
  • [17] COMBINED SPINAL AND EPIDURAL-ANESTHESIA
    VANDERMEERSCH, E
    KICK, O
    MOLLMANN, M
    DEGOUW, N
    VANAKEN, H
    ANAESTHESIST, 1991, 40 (12): : A108 - A112
  • [18] COMBINED SPINAL AND EPIDURAL-ANESTHESIA
    FELSBY, S
    JUELSGAARD, P
    ANESTHESIA AND ANALGESIA, 1995, 80 (04): : 821 - 826
  • [19] HEMODYNAMIC-EFFECTS FOLLOWING BOLUS - APPLICATION OF DIFFERENT VASOPRESSORS FOR REGULATION OF BLOOD-PRESSURE DURING EPIDURAL-ANESTHESIA
    MULLER, H
    BRAHLER, A
    BORNER, U
    BOLDT, J
    STOYANOV, M
    HEMPELMANN, G
    ANAESTHESIST, 1985, 34 (07): : A43 - A49