PULSATILE TOTAL ARTIFICIAL-HEART USING A REVERSIBLE ROTARY PUMP

被引:1
|
作者
FUKUNAGA, S
MITSUI, N
HOTEI, H
NAGATA, H
WATARI, M
TAHARA, K
SUEDA, T
MATSUURA, Y
机构
[1] First Department of Surgery, Hiroshima University School of Medicine, Hiroshima
关键词
ROTARY PUMP; TOTAL ARTIFICIAL HEART; PULSATILE FLOW; MOCK TEST;
D O I
10.1111/j.1525-1594.1995.tb02407.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A pump circuit was assembled and examined for use as an implantable artificial heart. The circuit consisted of a gear pump and 4 artificial heart valves. Mitral and pulmonary arterial valves were placed at the inflow port of the pump, and aortic and tricuspid valves were placed at the outflow port. The mitral and the tricuspid valves were connected to each reservoir at 10 mm Hg, and the aortic and the pulmonary arterial valves were connected to the head tanks at 80 and 20 mm Hg, respectively. The pump discharged pulsatile flows into both systemic and pulmonary arteries alternately by switching the direction of rotation periodically. Because the rated discharge was 1.7 L/min for the gear pump used, the measured flow rate was 0.8-0.75 L/min at a heart rate of 60-110 bpm.
引用
收藏
页码:701 / 703
页数:3
相关论文
共 50 条
  • [1] Characterization of a pulsatile rotary total artificial heart
    Jurney, Patrick L.
    Glynn, Jeremy J.
    Dykan, Igor V.
    Hagen, Matthew W.
    Kaul, Sanjiv
    Wampler, Richard K.
    Hinds, Monica T.
    Giraud, George D.
    ARTIFICIAL ORGANS, 2021, 45 (02) : 135 - 142
  • [2] DEVELOPMENT OF A FLOW-TRANSFORMED PULSATILE TOTAL ARTIFICIAL-HEART FOR TOTAL IMPLANTATION
    IMACHI, K
    CHINZEI, T
    ABE, Y
    MABUCHI, K
    IMANISHI, K
    YONEZAWA, T
    SUZUKI, A
    ISOYAMA, T
    ATSUMI, K
    FUJIMASA, I
    ARTIFICIAL ORGANS, 1992, 16 (03) : 308 - 313
  • [3] ROTARY PUMP ARTIFICIAL-HEART - A NEW SYSTEM FOR CIRCULATORY ASSISTANCE OR HEART REPLACEMENT
    MONTIES, JR
    HAVLIK, P
    MESANA, T
    TRINKL, J
    AUCOMTE, F
    GAUTHIER, T
    LIFE SUPPORT SYSTEMS, 1987, 5 (03): : 251 - 257
  • [4] PULSATILE VERSUS NON-PULSATILE FLOW IN THE DEVELOPMENT OF A TOTAL ARTIFICIAL-HEART (TAH)
    JACOBS, G
    HARASAKI, H
    SMITH, W
    KOIKE, S
    YADA, I
    GOLDING, L
    YOZU, R
    SATO, N
    OLSEN, E
    FUJIMOTO, L
    KIRALY, R
    NOSE, Y
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1983, 30 (08) : 533 - 534
  • [6] THE TOTAL ARTIFICIAL-HEART
    JARVIK, RK
    SCIENTIFIC AMERICAN, 1981, 244 (01) : 74 - &
  • [7] THE TOTAL ARTIFICIAL-HEART
    BAGBY, MM
    BINGGELI, B
    CURRENT, C
    DELOACH, C
    NICHOLSON, C
    PURVIANCE, K
    ROTH, G
    WEBER, J
    WEST, N
    WOOD, L
    AMERICAN JOURNAL OF NURSING, 1987, 87 (08) : 1050 - 1058
  • [8] TOTAL IMPLANTABLE AXIAL NON-PULSATILE BLOOD PUMP FOR LEFT-VENTRICULAR ASSIST AND TOTAL ARTIFICIAL-HEART REPLACEMENT
    SCHISTEK, R
    GENELIN, A
    HAGER, J
    NAGL, S
    NESSLER, N
    STOSS, F
    GSCHNITZER, F
    UNGER, F
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1982, 28 : 589 - 593
  • [9] FLOW-CONTROL IN AN ARTIFICIAL-HEART - THE DESIGN OF A MOTOR DRIVEN PULSATILE FLOW PUMP
    MABUCHI, K
    MORITA, M
    NISHIYAMA, K
    ITO, T
    ISHIHARA, A
    HASHIMOTO, S
    SASADA, T
    ARTIFICIAL ORGANS, 1981, 5 (03) : 313 - 313
  • [10] TOTAL ARTIFICIAL-HEART IMPLANTATION IN CALVES WITH PUMP OF AN ANGLED PORT DESIGN
    SHAFFER, LJ
    DONACHY, JH
    ROSENBERG, G
    PHILLIPS, WM
    LANDIS, DL
    PROPHET, GA
    OLSEN, E
    ARROWOOD, JA
    PIERCE, WS
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1979, 25 : 254 - 259