MASS-SPECTROMETRY STUDY OF A MAGNETRON PLANAR GLOW-DISCHARGE EXCITED IN THE DIRECT-CURRENT AND IN THE RADIOFREQUENCY MODE - AN EXPERIMENTAL-DESIGN APPROACH

被引:7
作者
MOLLE, C [1 ]
SPRINGAEL, S [1 ]
WAUTELET, M [1 ]
DAUCHOT, JP [1 ]
HECQ, M [1 ]
机构
[1] UNIV MONS,B-7000 MONS,BELGIUM
关键词
GLOW DISCHARGE; MASS SPECTROMETRY; EXPERIMENTAL DESIGN;
D O I
10.1366/0003702953964651
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A magnetron glow discharge is studied by a differentially pumped quadrupole mass spectrometer measuring the positive ions as well their energy, The 1-in.-diameter target is made in an aluminum base alloy. An ''experimental design'' procedure was used to study the influence of geometrical and electrical parameters of the discharge on the intensity and the energy of the ions collected by the mass filter. The ion intensity increases, in the de mode, by two orders of magnitude when the pressure drops from 450 mTorr to 20 mTorr, whereas, in the rf mode, a maximum is observed at 60 mTorr. For both discharge modes, the ion energy increases with a drop of the pressure and the ion intensity rises proportionally to the electric power. The energy of the ions entering into the mass filter is about 10 eV higher in the rf mode than in the de mode for the same power and pressure. Far most of the ions, their energy does not vary with the power. In the rf mode and at high pressure, a rise of their energy is observed when the target is eroded.