3-DIMENSIONAL RESTORATION OF SINGLE-PHOTON EMISSION COMPUTED-TOMOGRAPHY IMAGES

被引:14
作者
BOULFELFEL, D [1 ]
RANGAYYAN, RM [1 ]
HAHN, LJ [1 ]
KLOIBER, R [1 ]
机构
[1] FOOTHILLS PROV GEN HOSP,DIV NUCL MED,CALGARY T2N 2T9,AB,CANADA
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
10.1109/23.317385
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Restoration of single photon emission computed tomography (SPECT) images is usually performed either on two-dimensional (2-D) projection images (pre-reconstruction restoration) or on SPECT slices (post-reconstruction restoration). This study presents the application of a three-dimensional (3-D) filter in restoring SPECT images. The 3-D filter is shown to perform better than the 2-D methods because it takes into consideration the interslice information in the filtering process and has a relatively space-invariant blur function. To reduce the space-variance of the 3-D point spread function (PSF), conjugate projections were combined by geometric averaging before reconstruction. We investigated the potential of 3-D Wiener and power spectrum equalization (PSE) filters. These filters were applied to SPECT images of a resolution phantom and a large, truncated cone phantom containing two types of cold spots: a sphere, and a triangular prism. The filters were also applied to clinical images of the liver and spleen. The images were acquired on an ADAC GENESYS camera. A comparison was performed between results obtained in this study and those obtained by 2-D pre-reconstruction restoration and 2-D post-reconstruction restoration filters. Quantitative analysis of the 3-D restored images performed through measurement of root mean squared (RMS) errors and contrast ratios showed a considerable reduction in error and increase in contrast over images restored using the two other methods.
引用
收藏
页码:1746 / 1754
页数:9
相关论文
共 36 条
[1]   CONSTRAINED OPTIMIZATION AND ITS APPLICATION TO SCINTIGRAPHY [J].
BOARDMAN, AK .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (02) :363-371
[2]  
BOULFELFEL D, 1990, 1990 P IEEE C S AM, P112
[3]  
BOULFELFEL D, 1992, PHYS MED BIOL, P1915
[4]  
BOULFELFEL D, 1992, IEEE T MED IMAGING, P336
[5]  
BUDINGER TF, 1980, J NUCL MED, V21, P579
[7]   INVESTIGATION OF THE STATIONARITY OF THE MODULATION TRANSFER-FUNCTION AND THE SCATTER FRACTION IN CONJUGATE VIEW SPECT RESTORATION FILTERING [J].
COLEMAN, M ;
KING, MA ;
GLICK, SJ ;
KNESAUREK, K ;
PENNEY, BC .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) :969-972
[8]   STUDY OF THE APPLICATION OF A DECONVOLUTION METHOD TO SCINTIGRAPHY [J].
CORDIER, S ;
BIRAUD, Y ;
CHAMPAILLER, A ;
VOUTAY, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (03) :577-582
[9]  
DORE S, 1990, CANADIAN MEDICAL AND BIOLOGICAL ENGINEERING SOCIETY CONFERENCE : PROCEEDINGS -, P31
[10]  
DORE S, 1989, 11TH P IEEE ENG MED, P620