PHOTOSTIMULABLE PHOSPHOR DIGITAL RADIOGRAPHY OF THE EXTREMITIES - DIAGNOSTIC-ACCURACY COMPARED WITH CONVENTIONAL RADIOGRAPHY

被引:43
|
作者
WILSON, AJ
MANN, FA
MURPHY, WA
MONSEES, BS
LINN, MR
机构
[1] Mallinckrodt Inst. of Radiol., Washington University, School of Medicine, St. Louis
关键词
D O I
10.2214/ajr.157.3.1872241
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A direct comparison was made between digital and conventional radiographs to assess the relative accuracy of a photostimulable phosphor digital imaging system in detecting and localizing minor trauma in the extremities. Matched sets of images were obtained on 103 patients who came to the emergency department for radiographs of the hand, wrist, foot, or ankle. One set was obtained with a conventional screen/film system. The other set was obtained with photostimulable phosphor digital cassettes. The two sets of images of each patient were independently interpreted by three radiologists in a blinded fashion. The findings of each of these three readers were compared with the consensus opinion of two different radiologists. Receiver-operating-characteristic (ROC) curves were plotted for each of the three readers, areas under the curves were calculated, and true-positive fractions were determined at false-positive fractions of 0.1. Although no significant differences in the areas under the ROC curves for the two imaging systems were detected, conventional radiography showed a slight advantage. However, when true-positive fractions for fracture detection were compared at false-positive fractions of 0.1 a statistically significant difference was shown, with conventional screen/film radiography being more sensitive. This study raises questions about the use of currently available photostimulable phosphor systems for imaging trauma of the extremities and suggests that those systems should not be used exclusively.
引用
收藏
页码:533 / 538
页数:6
相关论文
共 50 条
  • [31] Infection Control in Digital Intraoral Radiography: Evaluation of Microbiological Contamination of Photostimulable Phosphor Plates in Barrier Envelopes
    MacDonald, David S.
    Waterfield, J. Douglas
    JOURNAL OF THE CANADIAN DENTAL ASSOCIATION, 2011, 77
  • [32] CHILDHOOD LEUKEMIA - DIAGNOSTIC-ACCURACY OF BEDSIDE CHEST RADIOGRAPHY FOR SEVERE PULMONARY COMPLICATIONS
    WINERMURAM, HT
    RUBIN, SA
    FLETCHER, BD
    KAUFFMAN, WM
    JENNINGS, SG
    ARHEART, KL
    BOZEMAN, PM
    RADIOLOGY, 1994, 193 (01) : 127 - 133
  • [33] Comparison the diagnostic accuracy of conventional radiography with ultrasound for the diagnosis of pneumonia
    Vafaei, Seyed Jahangir Ebrahimi
    Mohammadi, Susan
    Zamanimehr, Nahid
    Akhbari, Kourosh
    Roshani, Daem
    Azizkhani, Leila
    HEALTHY AGING RESEARCH, 2020, 9 (01)
  • [34] Diagnostic Accuracy of Conventional Radiography for Esophageal Foreign Bodies in Adults
    Saki, N.
    Nikakhlagh, S.
    Tahmasebi, M.
    IRANIAN JOURNAL OF RADIOLOGY, 2008, 5 (04) : 199 - 204
  • [35] DIGITAL LUMINESCENT RADIOGRAPHY - A SUBSTITUTE FOR CONVENTIONAL CHEST RADIOGRAPHY
    NEUFANG, KFR
    KRUG, B
    LORENZ, R
    STEINBRICH, W
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1990, 152 (05): : 501 - 509
  • [36] Conventional Radiography versus Digital Radiography in Endodontic Treatment
    Torres, Romulo Guillermo Lopez
    Freire, Karen Estefanny alvarez
    Carrera, Kevin Alexis Banos
    Sanchez, Kevin Josue Patino
    MEDISUR-REVISTA DE CIENCIAS MEDICAS DE CIENFUEGOS, 2024, 22 (06): : 1145 - 1151
  • [37] A COMPARISON OF DIGITAL RADIOGRAPHY AND CONVENTIONAL FILM SCREEN RADIOGRAPHY
    KALENDER, WA
    HUBENER, KH
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1984, 140 (01): : 87 - 92
  • [38] Diagnostic Accuracy of Digital and Conventional Radiography in the Detection of Non-Cavitated Approximal Dental Caries
    Abesi, Farida
    Mirshekar, Alireza
    Moudi, Ehsan
    Seyedmajidi, Maryam
    Haghanifar, Sina
    Haghighat, Nima
    Bijani, Ali
    IRANIAN JOURNAL OF RADIOLOGY, 2012, 9 (01) : 17 - 21
  • [39] Diagnostic accuracy and added value of dual-energy subtraction radiography compared to standard conventional radiography using computed tomography as standard of reference
    Martini, Katharina
    Baessler, Marco
    Baumueller, Stephan
    Frauenfelder, Thomas
    PLOS ONE, 2017, 12 (03):
  • [40] Comparison of the Accuracy of Digital Radiography with Conventional Radiography and Visual Examination in the Detection of Permanent Teeth Interproximal Caries
    Taghiloo, Hamid
    Taghiloo, Sina
    Rahbar, Mahdi
    Safabakhsh, Deniz
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2019, 19 (01):