PHOTOSTIMULABLE PHOSPHOR DIGITAL RADIOGRAPHY OF THE EXTREMITIES - DIAGNOSTIC-ACCURACY COMPARED WITH CONVENTIONAL RADIOGRAPHY

被引:43
|
作者
WILSON, AJ
MANN, FA
MURPHY, WA
MONSEES, BS
LINN, MR
机构
[1] Mallinckrodt Inst. of Radiol., Washington University, School of Medicine, St. Louis
关键词
D O I
10.2214/ajr.157.3.1872241
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A direct comparison was made between digital and conventional radiographs to assess the relative accuracy of a photostimulable phosphor digital imaging system in detecting and localizing minor trauma in the extremities. Matched sets of images were obtained on 103 patients who came to the emergency department for radiographs of the hand, wrist, foot, or ankle. One set was obtained with a conventional screen/film system. The other set was obtained with photostimulable phosphor digital cassettes. The two sets of images of each patient were independently interpreted by three radiologists in a blinded fashion. The findings of each of these three readers were compared with the consensus opinion of two different radiologists. Receiver-operating-characteristic (ROC) curves were plotted for each of the three readers, areas under the curves were calculated, and true-positive fractions were determined at false-positive fractions of 0.1. Although no significant differences in the areas under the ROC curves for the two imaging systems were detected, conventional radiography showed a slight advantage. However, when true-positive fractions for fracture detection were compared at false-positive fractions of 0.1 a statistically significant difference was shown, with conventional screen/film radiography being more sensitive. This study raises questions about the use of currently available photostimulable phosphor systems for imaging trauma of the extremities and suggests that those systems should not be used exclusively.
引用
收藏
页码:533 / 538
页数:6
相关论文
共 50 条
  • [1] New photostimulable phosphor materials for digital radiography
    Nanto, H
    Miyazaki, M
    Imai, A
    Komori, H
    Douguchi, Y
    Kusano, E
    Kinabara, A
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1202 - 1206
  • [2] New photostimulable phosphor materials for digital radiography
    Nanto, H
    Miyazaki, M
    Imai, A
    Komori, H
    Douguchi, Y
    Kusano, E
    Kinabara, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (04) : 1620 - 1624
  • [3] THE RELIABILITY AND DIAGNOSTIC ACCURACY OF DIGITAL TOMOSYNTHESIS COMPARED WITH CONVENTIONAL RADIOGRAPHY FOR THE INVESTIGATION OF SACROILIITIS
    Rischin, A.
    Kathpal, E.
    Vogrin, S.
    Bentley, L.
    Master, V.
    Steward, A.
    Le Marshall, K.
    Lim, K.
    ANNALS OF THE RHEUMATIC DISEASES, 2020, 79 : 1848 - 1848
  • [4] DATA-COMPRESSION - EFFECT ON DIAGNOSTIC-ACCURACY IN DIGITAL CHEST RADIOGRAPHY
    MACMAHON, H
    DOI, K
    SANADA, S
    MONTNER, SM
    GIGER, ML
    METZ, CE
    NAKAMORI, N
    YIN, FF
    XU, XW
    YONEKAWA, H
    TAKEUCHI, H
    RADIOLOGY, 1991, 178 (01) : 175 - 179
  • [5] THE EFFECTS OF KILOVOLTAGE ON DIAGNOSTIC-ACCURACY IN CHEST RADIOGRAPHY
    REVESZ, G
    SHEA, FJ
    KUNDEL, HL
    RADIOLOGY, 1982, 142 (03) : 615 - 618
  • [6] EXPOSURE MONITORING IN PHOTOSTIMULABLE PHOSPHOR COMPUTED RADIOGRAPHY
    WORKMAN, A
    COWEN, AR
    RADIATION PROTECTION DOSIMETRY, 1992, 43 (1-4) : 135 - 138
  • [7] PHYSICAL ASPECTS OF PHOTOSTIMULABLE PHOSPHOR COMPUTED RADIOGRAPHY
    COWEN, AR
    WORKMAN, A
    PRICE, JS
    BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (784): : 332 - 345
  • [8] Analysis of image defects in digital intraoral radiography based on photostimulable phosphor plates
    Tashiro, Masayasu
    Nakatani, Atsutoshi
    Sugiura, Kazutaka
    Nakayama, Eiji
    ORAL RADIOLOGY, 2023, 39 (02) : 355 - 363
  • [9] Analysis of image defects in digital intraoral radiography based on photostimulable phosphor plates
    Masayasu Tashiro
    Atsutoshi Nakatani
    Kazutaka Sugiura
    Eiji Nakayama
    Oral Radiology, 2023, 39 : 355 - 363
  • [10] CLINICAL-APPLICATIONS OF PHOTOSTIMULABLE PHOSPHOR COMPUTER RADIOGRAPHY
    SMATHERS, RL
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1986, 133 (08) : C339 - C339