Correlation of mixed venous and central venous oxygen saturation and its relation to cardiac index

被引:3
作者
Ramakrishna, M. N. [1 ]
Hegde, Devi Prasad [1 ]
Kumaraswamy, G. N. [1 ]
Gupta, Ratan [1 ]
Girish, T. N. [1 ]
机构
[1] Narayana Hrudayalaya Inst Med Sci, Adult ITU, 258-A Bommasandra, Bangalore, Karnataka, India
关键词
Cardiac index; central venous oxygen saturation; mixed venous oxygen saturation; shock;
D O I
10.4103/0972-5229.29841
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background and Aim: The clinical applicability of substitution of central venous oxygen saturation for mixed venous oxygen saturations in monitoring global tissue hypoxia is still a matter of controversy. Hence aim of the study is comparison of paired samples of mixed venous and central venous oxygen saturation and comparison in relation to cardiac index in varying hemodynamic conditions. Materials and Methods: Prospective clinical observation: Postoperative cardiac surgical ITU: 60 adult patients, >18 years of age of either sex: A PAC was inserted through (R) IJV, triple lumen catheter was inserted through (R) IJV. Blood samples were taken from distal tip of PAC and central venous catheters. An arterial blood sample was drawn from either radial or femoral arterial line. Measurements: Continuous cardiac output monitoring. Analysis of blood samples for hemoglobin concentration and oxygen saturation. Mixed venous oxygen saturations and central venous oxygen saturations were compared. The study was carried over a period of 30h in the postoperative period and samples were taken at 6h intervals. Patients were classified into three groups as follows depending on the CI: Low (< 2.5 L/m(2)), medium (2.5-4 L/m(2)), high (> 4 L/m(2)) and correlated with Svo(2) and Scvo(2). Results: 298 Comparative sets of samples were obtained. Svo2 was consistently lower than Scvo(2) throughout the study period. The difference was statistically significant. By using Bland - Altman plot, the mean difference between Svo(2) and Scvo(2) (Svo(2)-Scvo(2)) was - 2.9% +/- 5.14 and confidence limits are + 7.17% and - 12.97%. The co-efficient r is > 0.7 throughout the study period for all paired samples. The correlation Svo(2) and Scvo(2) with cardiac index in all the three groups were >0.7. Conclusion: Scvo(2) and Svo(2) are closely related and are interchangeable. Even though individual values differ trends in Scvo(2) may be substituted for trend in Svo(2)
引用
收藏
页码:230 / 234
页数:5
相关论文
共 8 条
  • [1] INFLUENCE OF CARDIAC-OUTPUT ON THE CORRELATION BETWEEN MIXED VENOUS AND CENTRAL VENOUS OXYGEN-SATURATION
    BERRIDGE, JC
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1992, 69 (04) : 409 - 410
  • [2] Trends but not individual values of central venous oxygen saturation agree with mixed venous oxygen saturation during varying hemodynamic conditions
    Dueck, MH
    Klimek, M
    Appenrodt, S
    Weigand, C
    Boerner, U
    [J]. ANESTHESIOLOGY, 2005, 103 (02) : 249 - 257
  • [3] Central venous and mixed venous oxygen saturation in critically ill patients
    Ladakis, C
    Myrianthefs, P
    Karabinis, A
    Karatzas, G
    Dosios, T
    Fildissis, G
    Gogas, J
    Baltopoulos, G
    [J]. RESPIRATION, 2001, 68 (03) : 279 - 285
  • [4] CENTRAL VENOUS OXYGEN SATURATION IN SHOCK - STUDY IN MAN
    LEE, J
    BARBER, R
    WRIGHT, F
    STANLEY, L
    [J]. ANESTHESIOLOGY, 1972, 36 (05) : 472 - &
  • [5] Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill
    Reinhart, K
    Kuhn, HJ
    Hartog, C
    Bredle, DL
    [J]. INTENSIVE CARE MEDICINE, 2004, 30 (08) : 1572 - 1578
  • [6] COMPARISON OF CENTRAL-VENOUS TO MIXED-VENOUS OXYGEN-SATURATION DURING CHANGES IN OXYGEN-SUPPLY DEMAND
    REINHART, K
    RUDOLPH, T
    BREDLE, DL
    HANNEMANN, L
    CAIN, SM
    [J]. CHEST, 1989, 95 (06) : 1216 - 1221
  • [7] CRITICAL ASSESSMENT OF USE OF CENTRAL VENOUS OXYGEN SATURATION AS A MIRROR OF MIXED VENOUS OXYGEN IN SEVERELY ILL CARDIAC PATIENTS
    SCHEINMAN, MM
    BROWN, MA
    RAPAPORT, E
    [J]. CIRCULATION, 1969, 40 (02) : 165 - +
  • [8] CAN CENTRAL VENOUS-BLOOD REPLACE MIXED VENOUS-BLOOD SAMPLES
    TAHVANAINEN, J
    MERETOJA, O
    NIKKI, P
    [J]. CRITICAL CARE MEDICINE, 1982, 10 (11) : 758 - 761