ELECTRON-BEAM TOMOGRAPHY OF MAGNETIC RECORDING HEAD FIELDS

被引:6
|
作者
FERRIER, RP [1 ]
LIU, Y [1 ]
MARTIN, JL [1 ]
ARNOLDUSSEN, TC [1 ]
机构
[1] IBM CORP,DIV STORAGE SYST,SAN JOSE,CA 95193
关键词
Air bearing surface - Backscattered electron imaging - Differential phase contrast mode - Electron beam deflection - Electron beam tomography - Kerr optical microscopy - Lorentz electron microscopy - Magnetic recording head fields - Radom transform method;
D O I
10.1016/0304-8853(95)00304-5
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The quantitative evaluation of the 3D form of the magnetic field from a thin film recording head has been achieved by electron beam tomography. The data sets for tomographic reconstruction were obtained using the differential phase contrast mode of Lorentz electron microscopy applied in a 200 kV (scanning) transmission instrument. The high accelerating voltage and a novel method of mounting the head in the microscope offer advantages over previous experiments. The two reconstruction algorithms, which have been used previously, have been implemented and the results of their application are compared for theoretical data derived from a model head field and for data obtained experimentally from a production recording head.
引用
收藏
页码:387 / 397
页数:11
相关论文
共 50 条
  • [31] A NOVEL METHOD OF ELECTRON-BEAM RECORDING ON A SI WAFER
    MUNAKATA, C
    MIYAZAKI, M
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1981, 20 (04) : L293 - L295
  • [32] STABILIZATION FOR DEVELOPMENT OF THERMOPLASTIC FILM IN ELECTRON-BEAM RECORDING
    MINEMOTO, T
    NOZAWA, T
    FUKUDA, Y
    OPTICS COMMUNICATIONS, 1981, 36 (02) : 111 - 116
  • [33] LIQUID-CRYSTAL MEDIA FOR ELECTRON-BEAM RECORDING
    HANSEN, JR
    SCHNEEBE.RJ
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1968, ED15 (06) : 424 - &
  • [34] ELECTRON-BEAM DOSE COMPUTATIONS FOR SHAPED FIELDS
    CHOI, MC
    AGARWAL, SK
    BERK, HW
    BHADURI, D
    MEDICAL PHYSICS, 1984, 11 (03) : 378 - 378
  • [35] ELECTRON-BEAM TREATMENT OF CANCER OF HEAD AND NECK
    TAPLEY, NDV
    ENT-EAR NOSE & THROAT JOURNAL, 1977, 56 (03) : 74 - +
  • [36] Functional imaging with electron-beam computed tomography
    Becker, A
    Becker, C
    Knez, A
    Haberl, R
    Brüning, R
    Reiser, M
    Steinbeck, G
    RADIOLOGE, 1998, 38 (12): : 1021 - 1028
  • [37] Application of pharmacokinetics to electron-beam tomography of the abdomen
    Krause, W
    Gröll, R
    Kern, R
    Baumgartner, C
    Rienmüller, R
    ACADEMIC RADIOLOGY, 1999, 6 (08) : 487 - 495
  • [38] ELECTRON-BEAM THERAPY OF HEAD AND NECK TUMORS
    TOBIN, DA
    BYRD, SL
    SCOTT, RM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1974, 120 (03) : 617 - 623
  • [39] Usefulness of electron-beam computed tomography - Discussion
    Crouse, JR
    Raggi, P
    Black, D
    Hecht, H
    Grines, C
    Budoff, M
    AMERICAN JOURNAL OF CARDIOLOGY, 2002, 89 (4A): : 22B - 23B
  • [40] MAGNETIC COMPRESSION OF A RELATIVISTIC ELECTRON-BEAM
    VLASOV, MA
    KOVALENKO, YA
    MALAFEEV, OA
    NIKONOV, SV
    RADIOTEKHNIKA I ELEKTRONIKA, 1981, 26 (11): : 2370 - 2373