Magnetic Susceptibility Artifact in Orbital Magnetic Resonance Imaging

被引:1
作者
Chen, S. I. [1 ]
Chandna, A. [1 ]
Aberneythy, L. J. [2 ]
机构
[1] Royal Liverpool Childrens Hosp, Dept Ophthalmol, Eaton Rd, Liverpool L12 2AP, Merseyside, England
[2] Royal Liverpool Childrens Hosp, Dept Radiol, Liverpool, Merseyside, England
关键词
Magnetic resonance imaging; artifacts; lateral rectus; esotropia; strabismus surgery; botulinum toxin;
D O I
10.1080/09273970490887485
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Case report of a 16-year-old boy presenting with total hyphema due to blunt trauma to the left eye. During a subsequent cinematic MRI scan to identify salvageable lateral rectus muscle, the attachment of the left lateral rectus was obscured by a 20-mm diameter signal void. A subsequent CT scan for a suspected metallic foreign body revealed the muscle attachment after all. The theoretical explanations for this finding are discussed.
引用
收藏
页码:1 / 3
页数:3
相关论文
共 7 条
  • [1] CINE MAGNETIC-RESONANCE-IMAGING OF EYE-MOVEMENTS
    BAILEY, CC
    KABALA, J
    LAITT, R
    WESTON, M
    GODDARD, P
    HOH, HB
    POTTS, MJ
    HARRAD, RA
    [J]. EYE, 1993, 7 : 691 - 693
  • [2] Anatomy of the orbital apex and cavernous sinus on high-resolution magnetic resonance images
    Ettl, A
    Zwrtek, K
    Daxer, A
    Salomonowitz, E
    [J]. SURVEY OF OPHTHALMOLOGY, 2000, 44 (04) : 303 - 323
  • [3] Lenticular opacities in individuals exposed to ionizing radiation in infancy
    Hall, P
    Granath, F
    Lundell, M
    Olsson, K
    Holm, LE
    [J]. RADIATION RESEARCH, 1999, 152 (02) : 190 - 195
  • [4] Artifacts and pitfalls in MR imaging of the orbit: A clinical review
    Herrick, RC
    Hayman, LA
    Taber, KH
    DiazMarchan, PJ
    Kuo, MD
    [J]. RADIOGRAPHICS, 1997, 17 (03) : 707 - 724
  • [5] POTENTIAL HAZARDS AND ARTIFACTS OF FERROMAGNETIC AND NONFERROMAGNETIC SURGICAL AND DENTAL MATERIALS AND DEVICES IN NUCLEAR MAGNETIC-RESONANCE IMAGING
    NEW, PFJ
    ROSEN, BR
    BRADY, TJ
    BUONANNO, FS
    KISTLER, JP
    BURT, CT
    HINSHAW, WS
    NEWHOUSE, JH
    POHOST, GM
    TAVERAS, JM
    [J]. RADIOLOGY, 1983, 147 (01) : 139 - 148
  • [6] MR PROCEDURES AND BIOMEDICAL IMPLANTS, MATERIALS, AND DEVICES - 1993 UPDATE
    SHELLOCK, FG
    MORISOLI, S
    KANAL, E
    [J]. RADIOLOGY, 1993, 189 (02) : 587 - 599
  • [7] Speeg-Schatz C, 1998, Binocul Vis Strabismus Q, V13, P105