X-RAY EXAMINATIONS OF PERIPHERAL JOINTS - COMPARISON OF DIGITAL LUMINESCENT RADIOGRAPHY (DLR) AND SCREEN-FILM SYSTEM COMBINATIONS

被引:7
作者
KRUG, B
FISCHBACH, R
HERRMANN, S
DIETLEIN, M
KUPPER, T
DOLKEN, W
HARNISCHMACHER, U
机构
[1] UNIV COLOGNE, RADIOL DIAGNOST POLIKLIN, W-5000 COLOGNE 41, GERMANY
[2] UNIV COLOGNE, INST MED DOKUMENTAT & STAT, W-5000 COLOGNE 41, GERMANY
来源
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN | 1993年 / 158卷 / 02期
关键词
DIGITAL LUMINESCENT RADIOGRAPHY (DLR); SCREEN-FILM SYSTEM COMBINATIONS; EXAMINATION OF PERIPHERAL JOINTS;
D O I
10.1055/s-2008-1032618
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
175 matched skeletal x-ray examinations were carried out by digital luminescent radiography (DLR) and conventional screen-film system combinations. In digital luminescent radiography (DLR) two differently postprocessed images were obtained from one x-ray exposure: A display with low spatial frequency enhancement was opposed to a second display with high edge enhancement. Conventional and digital images were evaluated randomly and separately by four radiologists using a questionnaire. DLR proved to be diagnostically equivalent to the conventional technique except for a diminished visibility of subtle erosions and fissures. As major advantages of DLR maybe pointed out that faulty exposures were avoided by the automatic adjustment of image brightness and that the soft tissue margins could be more easily delineated in displays with high edge enhancement than in conventional radiography. However, digital displays with high edge enhancement did not provide additional diagnostic information and led to artifacts at the edges of metal prostheses.
引用
收藏
页码:133 / 140
页数:8
相关论文
共 24 条
  • [1] BOHNDORF K, 1989, ORTHOPADE, V18, P66
  • [2] BUCHMANN F, 1987, MED TECHNIK, V107, P163
  • [3] BUSCH HP, 1991, JB RADIOLOGIE, P47
  • [4] DOHRING W, 1986, RONTGENSTRAHLEN, V56, P16
  • [5] GALANSKI M, 1990, DIGITALE BILDGEBUNG, P234
  • [6] GEISSELSOEDER P, 1990, Electromedica (English Edition), V58, P38
  • [7] DIGITAL RADIOGRAPHY - EXPERIENCES WITH THE SP SYSTEM
    HINTZE, A
    JOTTEN, G
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1986, 145 (01): : 91 - 97
  • [8] DIGITAL GASTROINTESTINAL IMAGING - THE EFFECT OF PIXEL SIZE ON DETECTION OF SUBTLE MUCOSAL ABNORMALITIES
    KASTAN, DJ
    ACKERMAN, LV
    FECZKO, PJ
    [J]. RADIOLOGY, 1987, 162 (03) : 853 - 856
  • [9] FRACTURE DIAGNOSIS USING THE DIGITAL STORAGE PHOSPHORUS SYSTEM
    KLEIN, HM
    WEIN, B
    LANGEN, HJ
    GLASER, KH
    STARGARDT, A
    GUNTHER, RW
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 154 (06): : 582 - 586
  • [10] COMPARISON OF DIGITAL LUMINESCENCE RADIOGRAPHY (DLR) AND CONVENTIONAL FILM-SCREEN SYSTEM COMBINATIONS IN SIALOGRAPHIES
    KRUG, B
    FRIEDMANN, G
    STEINBRICH, W
    LOENNECKEN, I
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1989, 150 (06): : 718 - 722