LEFT-VENTRICULAR FUNCTION DURING TRANSIENT CORONARY-OCCLUSION - DIGITAL SUBTRACTION LEFT VENTRICULOGRAMS DURING CORONARY ANGIOPLASTY

被引:5
作者
KITAZUME, H
KUBO, I
IWAMA, T
AGEISHI, Y
SUZUKI, A
机构
[1] BOKUTO HOSP,DEPT MED,TOKYO,JAPAN
[2] TOKYO MED & DENT UNIV,DEPT THORAC SURG,TOKYO 113,JAPAN
关键词
CORONARY ANGIOPLASTY; LEFT VENTRICULAR FUNCTION; DIGITAL SUBTRACTION ANGIOGRAPHY;
D O I
10.1002/clc.4960140808
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The impact of transient myocardial ischemia on left ventricular function was examined by digital subtraction left ventricular angiography. Contrast medium was injected into the right pulmonary artery before, at 60 seconds of balloon inflation, and 10 minutes after balloon deflation. A total of 69 patients completed the study. In 52 patients, the left anterior descending artery (LAD) was involved, and in 17, the right coronary artery (RCA) was the focus. Ejection fraction (EF) declined by balloon inflation and returned to baseline value after deflation of the balloon. There was tendency toward a lower EF and wider akinetic area for LAD dilatation. The linear correlation between resting EF and EF during balloon inflation suggested that the effect of momentary coronary occlusion on left ventricular function appears to be additive to pre-existing left ventricular dysfunction, and resting ejection fraction is an important parameter for estimating the degree of diminished left ventricular function during myocardial ischemia.