THE EFFECT OF CONTINUOUS POSITIVE AIRWAY PRESSURE VERSUS POSITIVE END-EXPIRATORY PRESSURE ON THE DIAPHRAGM

被引:2
|
作者
ROAD, JD
LEEVERS, AM
GRASSINO, A
机构
[1] Department of Medicine, University of British Columbia, Vancouver, BC
[2] Notre Dame Hospital, The Meakins-Christie Laboratories, Montreal, Que.
关键词
D O I
10.1016/0883-9441(91)90004-D
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Continuous positive airway pressure (CPAP) and positive end-expiratory pressure (PEEP) both increase lung volume and hence may compromise diaphragm function. However, the effects of these two positive airway pressure modalities on inspiratory work of breathing are conflicting. In this study, we compared the effect of CPAP versus PEEP on diaphragm function in spontaneously breathing anesthetized dogs. Eight sodium pentobarbital-anesthetized dogs were randomly exposed to various levels of CPAP and PEEP. Measurements of diaphragmatic shortening, transdiaphragmatic pressure swings, and diaphragmatic electromyogram (EMG) were made. The change in lung volume and diaphragm length was similar at equivalent airway pressures during PEEP or CPAP. Therefore, expiratory muscle recruitment in the two conditions was equivalent. However, tidal diaphragmatic EMG and transdiaphragmatic pressure swings increased markedly during PEEP compared with CPAP. At a PEEP of 18 cm H2O, crural and costal EMG activities were 185% ± 16% and 163% ± 8% of control, respectively, whereas during CPAP the EMG activity was 66% ± 11 % of control for both the costal and the crural diaphragms (±SE). During PEEP, the duration of neural inspiration (TIEMG) was greater than the duration of inspiration as measured by airflow (TIV). On the other hand, during CPAP, TIEMG was less than TIV. We conclude that although expiratory muscle recruitment is comparable and tidal volume greater during CPAP, the inspiratory activation of the diaphragm decreases with CPAP but increases markedly with PEEP. © 1991.
引用
收藏
页码:136 / 142
页数:7
相关论文
共 50 条
  • [21] The effect of positive end-expiratory pressure on pulse pressure variation
    Smith, F. J.
    Geyser, M.
    Schreuder, I
    Becker, P. J.
    SOUTHERN AFRICAN JOURNAL OF ANAESTHESIA AND ANALGESIA, 2012, 18 (06) : 333 - 338
  • [22] POSITIVE END-EXPIRATORY AIRWAY PRESSURE IN SEVERE ARTERIAL HYPOXEMIA
    MCMAHON, SM
    HALPRIN, GM
    SIEKER, HO
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1973, 108 (03): : 526 - 535
  • [23] POSITIVE END-EXPIRATORY PRESSURE THERAPY
    APPLEFELD, JJ
    ANNALS OF INTERNAL MEDICINE, 1973, 79 (05) : 762 - 762
  • [24] POSITIVE END-EXPIRATORY PRESSURE IS NO PANACEA
    ODONOHUE, WJ
    CHEST, 1979, 76 (04) : 373 - 374
  • [25] POSITIVE END-EXPIRATORY PRESSURE - A REVIEW
    TYLER, DC
    CRITICAL CARE MEDICINE, 1983, 11 (04) : 300 - 308
  • [26] POSITIVE END-EXPIRATORY PRESSURE (PEEP)
    HEINRICHS, W
    ANAESTHESIST, 1992, 41 (10): : 653 - 669
  • [27] PEEP (positive end-expiratory pressure)
    Max, M
    ANAESTHESIST, 2001, 50 (03): : 198 - 199
  • [28] Positive end-expiratory pressure affects geometry and function of the human diaphragm
    Jansen, Diana
    Jonkman, Annemijn H.
    de Vries, Heder J.
    Wennen, Myrte
    Elshof, Judith
    Hoofs, Maud A.
    van den Berg, Marloes
    de Man, Angelique M. E.
    Keijzer, Christiaan
    Scheffer, Gert-Jan
    van der Hoeven, Johannes G.
    Girbes, Armand
    Tuinman, Pieter Roel
    Marcus, J. Tim
    Ottenheijm, Coen A. C.
    Heunks, Leo
    JOURNAL OF APPLIED PHYSIOLOGY, 2021, 131 (04) : 1328 - 1339
  • [29] EFFECT OF POSITIVE END-EXPIRATORY PRESSURE ON POSTOPERATIVE BLEEDING
    THOMSON, DS
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1984, 88 (03): : 457 - 457
  • [30] EFFECTS OF DISPOSABLE OR INTERCHANGEABLE POSITIVE END-EXPIRATORY PRESSURE VALVES ON WORK OF BREATHING DURING THE APPLICATION OF CONTINUOUS POSITIVE AIRWAY PRESSURE
    KACMAREK, RM
    MANG, H
    BARKER, N
    CYCYKCHAPMAN, MC
    CRITICAL CARE MEDICINE, 1994, 22 (08) : 1219 - 1226