ELECTRON-BEAM DOSIMETRY FOR A MULTILAYER ABSORBER

被引:0
|
作者
MATSUDA, K [1 ]
KIJIMA, T [1 ]
机构
[1] OSAKA INST TECHNOL,DEPT ELECTR ENGN,OSAKA 535,JAPAN
关键词
D O I
暂无
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Depth dose distributions were measured in a multilayer absorber of Ti-air-cellulose triacetate (CTA)-backing material (Pb, Sn, Fe, Al and CTA) irradiated with 300 and 800-keV electrons. The results are compared with the calculated value using computational code for multilayer absorbers (EDMULT) developed by Tabata et al. (1989, 1990). The absorbed dose in CTA exceeds the calculated value near the surface, while it is smaller than the calculated dose as the penetration depth becomes closer to the range of incident electrons. The measurements and computations show better agreement for the high-energy (800-keV) electrons than for the 300-keV electrons, probably because of the greater obiqueness of incidence at lower energies, which is not taken into account by the computation code.
引用
收藏
页码:235 / 239
页数:5
相关论文
共 50 条
  • [31] Multilayer electron-beam curing of polymer dielectric for electrical interconnections
    Manepalli, R
    Farnsworth, KD
    Allen, SAB
    Kohl, PA
    ELECTROCHEMICAL AND SOLID STATE LETTERS, 2000, 3 (05) : 228 - 231
  • [32] REFERENCE DOSIMETRY STUDY FOR 3 MEV ELECTRON-BEAM ACCELERATOR IN MALAYSIA
    ALI, NM
    SUNAGA, H
    TANAKA, R
    RADIATION PHYSICS AND CHEMISTRY, 1995, 46 (4-6): : 1255 - 1258
  • [33] ELECTRON-BEAM DOSIMETRY USING RADIATION-INDUCED FLUORESCENCE OF POLYETHYLENE
    RADOVSKY, DA
    BRUMBERG.H
    NATURE, 1967, 216 (5114) : 469 - &
  • [34] CLINICAL-EVALUATION OF AN ALGORITHM FOR INHOMOGENEITY CORRECTIONS OF ELECTRON-BEAM DOSIMETRY
    FIELDS, RS
    HOGSTROM, KR
    SPANOS, WJ
    MILLS, MR
    MCNEESE, MD
    ALMOND, PR
    CUNDIFF, JH
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1981, 7 (09): : 1231 - 1231
  • [35] PARAMETRIZATION OF LINEAR-ACCELERATOR ELECTRON-BEAM FOR COMPUTERIZED DOSIMETRY CALCULATIONS
    MILLAN, PE
    MILLAN, S
    HERNANDEZ, A
    ANDREO, P
    PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (04): : 825 - 827
  • [36] BREAST DOSE DURING ELECTRON-BEAM CT - MEASUREMENT WITH FILM DOSIMETRY
    MCCOLLOUGH, CH
    LIU, HH
    RADIOLOGY, 1995, 196 (01) : 153 - 157
  • [37] ON THE CALIBRATION OF PLANE-PARALLEL IONIZATION CHAMBERS FOR ELECTRON-BEAM DOSIMETRY
    ANDREO, P
    RODRIGUES, LN
    LINDBORG, L
    KRAEPELIEN, T
    PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (05): : 1147 - 1165
  • [38] STOPPING-POWER RATIOS AND THEIR UNCERTAINTIES FOR CLINICAL ELECTRON-BEAM DOSIMETRY
    ANDREO, P
    FRANSSON, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (12): : 1847 - 1861
  • [39] POWER-DENSITY OF ELECTRON-BEAM IN AN ELECTRON-BEAM WELDER
    IRIE, H
    HASHIMOTO, T
    INAGAKI, M
    TRANSACTIONS OF NATIONAL RESEARCH INSTITUTE FOR METALS, 1980, 22 (02): : 95 - 103
  • [40] ELECTRON-BEAM TECHNOLOGY AND ELECTRON-BEAM TARGET EXPERIMENTAL RESULTS
    TOEPFER, AJ
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1977, 26 : 9 - 10