MAGNETIC-RESONANCE VELOCITY-MEASUREMENTS IN SMALL ARTERIES - COMPARISON WITH DOPPLER ULTRASONIC MEASUREMENTS IN THE AORTAS OF NORMAL RABBITS

被引:9
作者
WENDT, RE
ROKEY, R
WONG, WF
MARKS, A
机构
[1] BAYLOR COLL MED,CTR MAGNET RESONANCE,HOUSTON,TX 77030
[2] BAYLOR COLL MED,DEPT MED,CARDIOL SECT,HOUSTON,TX 77030
关键词
DOPPLER ULTRASOUND VELOCITY MEASUREMENT; MAGNETIC RESONANCE IMAGING; VELOCITY IMAGING; VELOCITY SPECTRA;
D O I
10.1097/00004424-199207000-00002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. Magnetic resonance imaging (MRI) can be used to measure motion. This study compares MRI blood flow velocity measurements to Doppler ultrasound velocity measurements in an animal model. MATERIALS AND METHODS. Blood flow in the abdominal aortas of nine normal rabbits was measured using 16-frame, velocity-resolved MRI and Doppler ultrasound. The MRI data were processed into velocity spectra to aid in their interpretation. RESULTS. Maximum velocity measurements made by rangegated Doppler ultrasound were predicted by the maximum velocity values derived from MR velocity spectra with a slope of 0.861, an intercept of -2.78 cm/second, and an R-value of 0.935 in 70 measurements. CONCLUSIONS. Despite the longer time required for the MR measurement, the MR velocity measurement may be useful in the assessment of deep vessels or those obscured by other structures, which are difficult to measure with ultrasound.
引用
收藏
页码:499 / 503
页数:5
相关论文
共 17 条
[1]  
[Anonymous], 1986, NUMERICAL RECIPES
[2]   SOME CHARACTERISTICS OF LAMINAR-FLOW VELOCITY SPECTRA DETECTED BY A 20 MHZ PULSED ULTRASOUND DOPPLER [J].
BROWN, TD ;
GABEL, RH ;
PEDERSEN, DR ;
BELL, LD ;
BLAIR, WF .
JOURNAL OF BIOMECHANICS, 1985, 18 (12) :927-+
[3]   PULSED NMR-STUDY ON THE FLOW OF FLUID [J].
FUKUDA, K ;
HIRAI, A .
JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1979, 47 (06) :1999-2006
[4]   NMR SPIN-ECHO FLOW MEASUREMENTS [J].
GROVER, T ;
SINGER, JR .
JOURNAL OF APPLIED PHYSICS, 1971, 42 (03) :938-&
[5]  
HARTLEY C J, 1978, Ultrasound in Medicine and Biology, V4, P99, DOI 10.1016/0301-5629(78)90035-2
[6]   ULTRASONIC PULSED DOPPLER SYSTEM FOR MEASURING BLOOD-FLOW IN SMALL VESSELS [J].
HARTLEY, CJ ;
COLE, JS .
JOURNAL OF APPLIED PHYSIOLOGY, 1974, 37 (04) :626-629
[7]   COMPARISON OF HEPATIC EXTRACTION OF INSULIN AND GLUCAGON IN CONSCIOUS AND ANESTHETIZED DOGS [J].
ISHIDA, T ;
LEWIS, RM ;
HARTLEY, CJ ;
ENTMAN, ML ;
FIELD, JB .
ENDOCRINOLOGY, 1983, 112 (03) :1098-1109
[8]  
Moran P. R., 1984, Technology of Nuclear Magnetic Resonance. 14th Annual Symposium on the Sharing of Computer Programs and Technology, P149
[9]   FACTORS AFFECTING THE CONTINUOUS WAVE DOPPLER SPECTRUM FOR THE DIAGNOSIS OF CAROTID ARTERIAL-DISEASE [J].
MORIN, JF ;
JOHNSTON, KW ;
LAW, YF .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1988, 14 (03) :175-189
[10]   BLOOD-FLOW IMAGING BY CINE MAGNETIC-RESONANCE [J].
NAYLER, GL ;
FIRMIN, DN ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (05) :715-722