Stent hypersensitivity and infection in sinus cavities

被引:10
作者
Kounis, Nicholas G. [1 ]
Soufras, George D. [1 ]
Hahalis, George [1 ]
机构
[1] Patras Highest Inst Educ & Technol, Dept Med Sci, 7 Aratou St, Patras 26221, Greece
关键词
D O I
10.2500/ar.2013.4.0071
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Persistent mucosal inflammation, granulation tissue formation, hypersensitivity, and multifactorial infection are newly described complications of retained drug-eluting stents from endoscopic sinus surgery for refractory rhinosinusitis. In an important report published in Allergy and Rhinology, a 45-year-old male patient suffering from recalcitrant chronic rhinosinusitis underwent functional endoscopic sinus surgery and was found, for the first time, to have steroid-eluting catheters that were inadvertently left in the ethmoid and frontal sinuses. The retained catheters had caused persistent mucosal inflammation and formation of granulation tissue denoting hypersensitivity reaction. These consequences had induced perpetuation of symptoms of chronic rhinosinusitis. Meticulous removal of the retained stents with the nitinol wings from inflamed tissues of the frontal, ethmoidal, and sphenoethmoidal recesses in which they were completely imbedded was successfully performed without polypoid regrowth. Cultures of specimens taken from both left and right stents showed heavy growth of Stenotrophomonas maltophilia and moderate growth of Klebsiella oxytoca, coagulase negative Staphylococcus, and beta-hemolytic Streptococcus anginosus. Fungal infection was not detected. The current knowledge and experience regarding stent hypersensitivity and infection in relation with the use of stents in sinus cavities is reviewed.
引用
收藏
页码:E162 / E165
页数:4
相关论文
共 34 条
  • [1] Nonvalvular cardiovascular device-related infections
    Baddour, LM
    Bettmann, MA
    Bolger, AF
    Epstein, AE
    Ferrieri, P
    Gerber, MA
    Gewitz, MH
    Jacobs, AK
    Levison, ME
    Newburger, JW
    Pallasch, TJ
    Wilson, WR
    Baltimore, RS
    Falace, DA
    Shulman, ST
    Tani, LY
    Taubert, KA
    [J]. CIRCULATION, 2003, 108 (16) : 2015 - 2031
  • [2] Bednarski Karen A, 2009, Otolaryngol Clin North Am, V42, P857, DOI 10.1016/j.otc.2009.07.001
  • [3] Self-expandable metal stents as a new treatment option for perforated duodenal ulcer
    Bergstrom, M.
    Vazquez, J. A. Arroyo
    Park, P. -O.
    [J]. ENDOSCOPY, 2013, 45 (03) : 222 - 225
  • [4] Effects of Topically Applied Dexamethasone on Mucosal Wound Healing Using a Drug-Releasing Stent
    Beule, Achim G.
    Scharf, Christian
    Biebler, Karl-Ernst
    Goepferich, Achim
    Steinmeier, Elke
    Wolf, Eduard
    Hosemann, Werner
    Kaftan, Holger
    [J]. LARYNGOSCOPE, 2008, 118 (11) : 2073 - 2077
  • [5] Long-term selective IgE-mediated hypersensitivity to hydrocortisone sodium succinate
    Calogiuri, G. F.
    Nettis, E.
    Di Leo, E.
    Muratore, L.
    Ferrannini, A.
    Vacca, A.
    [J]. ALLERGOLOGIA ET IMMUNOPATHOLOGIA, 2013, 41 (03) : 206 - 208
  • [6] ADVANCE: A Multisite Trial of Bioabsorbable Steroid-Eluting Sinus Implants
    Forwith, Keith D.
    Chandra, Rakesh K.
    Yun, Paul T.
    Miller, Steven K.
    Jampel, Henry D.
    [J]. LARYNGOSCOPE, 2011, 121 (11) : 2473 - 2480
  • [7] C-reactive protein, clinical outcome, and restenosis rates after implantation of different drug-eluting stents
    Gaspardone, A
    Versaci, F
    Tomai, F
    Citone, C
    Proietti, I
    Gioffrè, G
    Skossyreva, O
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (09) : 1311 - 1316
  • [8] Greif Martin, 2009, Cases J, V2, P7800, DOI 10.4076/1757-1626-2-7800
  • [9] Evaluation of a high-dose Dexamethasone-eluting stent
    Hoffmann, R
    Langenberg, R
    Radke, P
    Franke, A
    Blindt, R
    Ortlepp, J
    Popma, JJ
    Weber, C
    Hanrath, P
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (02) : 193 - 195
  • [10] Huang Yanming, 2003, Int J Cardiovasc Intervent, V5, P166