Evaluation of the American Society of Cataract and Refractive Surgery intraocular lens calculator for eyes with prior radial keratotomy

被引:14
|
作者
DeMill, David L. [1 ]
Hsu, Maylon [1 ]
Moshirfar, Majid [1 ]
机构
[1] Univ Utah, John A Moran Eye Ctr, Salt Lake City, UT 84112 USA
来源
CLINICAL OPHTHALMOLOGY | 2011年 / 5卷
关键词
radial keratotomy; cataract; intraocular lens calculator; American Society of Cataract and Refractive Surgery;
D O I
10.2147/OPTH.S24514
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: The purpose of this study was to evaluate the American Society of Cataract and Refractive Surgery (ASCRS) intraocular lens (IOL) calculator for eyes with prior radial keratotomy and assess the accuracy of its methods in predicting IOL power in patients with previous radial keratotomy. Methods: This retrospective study included data from 15 eyes with previous radial keratotomy and subsequent cataract surgery. The average central power and Humphrey Atlas methods from the ASCRS IOL calculator, along with an average IOL power produced from an average of these two methods (ASCRS average), were compared. Primary outcome measures for each method were mean arithmetic and absolute IOL prediction error, variance in mean arithmetic IOL prediction error, and the percentage of refractive outcomes within +/- 0.50, +/- 1.00, +/- 1.50, and +/- 2.00 diopters (D). Results: The average central power method and the ASCRS average were significantly more accurate than the Humphrey Atlas method in terms of mean absolute IOL prediction error (1.03 D and 1.02 D versus 1.53; P = 0.04 and P = 0.01, respectively). In addition, the average central power method and ASCRS average produced a higher percentage of refractive outcomes within +/- 0.50 D when compared with the Humphrey Atlas method (60% and 46.67% versus 0%, respectively). A comparison of the average central power method and the ASCRS average demonstrated a smaller variance and higher percentage of patients within +/- 1.00 D when using the ASCRS average. Conclusion: The ASCRS calculator for eyes with prior radial keratotomy is an easily accessible and valuable online tool for calculating IOL power in patients with previous radial keratotomy. We found that the ASCRS average produced by the calculator provided the best IOL prediction. We recommend using it with the addition of 1.00 to 1.50 D to its IOL power prediction.
引用
收藏
页码:1243 / 1247
页数:5
相关论文
共 50 条
  • [21] Intraocular lens power prediction in patients who undergo cataract surgery following previous radial keratotomy
    Lyle, WA
    Jin, GJC
    ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (04) : 457 - 461
  • [22] Intraocular lens power calculation in high myopic eyes with previous radial keratotomy
    Han, Eui Seok
    Lee, Jin Hak
    JOURNAL OF REFRACTIVE SURGERY, 2006, 22 (07) : 713 - 716
  • [23] Radial keratotomy to treat myopic refractive error after cataract surgery
    Oshika, T
    Yoshitomi, F
    Fukuyama, M
    Hara, Y
    Shimokawa, S
    Shiwa, T
    Sakabe, I
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (01): : 50 - 55
  • [24] Analysis of intraocular lens power calculation in post-radial keratotomy eyes
    Chen, L
    Mannis, MJ
    Salz, JJ
    Garcia-Ferrer, FJ
    Ge, J
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (01): : 65 - 70
  • [25] Multifocal Intraocular Lens Results in Correcting Presbyopia in Eyes After Radial Keratotomy
    Kim, Kyeong Hwan
    Seok, Kyung-won
    Kim, Wan Soo
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2017, 43 (06): : E22 - E25
  • [26] Comparison of the Accuracy of Toric Intraocular Lens Formulas Used by the Online Calculator of the European Society of Cataract and Refractive Surgeons
    Liu, Chang
    Wang, Mengyu
    Long, Da
    Zhang, Ye
    Chen, Yan
    Wu, Qiang
    JOURNAL OF REFRACTIVE SURGERY, 2025, 41 (02)
  • [27] Intraocular lens power prediction in eyes with prior radial keratotomy using Fourier-domain optical coherence tomography
    Waisbren, Emily
    Wang, Li
    Tang, Maolong
    Koch, Douglas
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [28] Refractive results of cataract surgery using optical biometry and Haigis formula in eyes with refractive keratotomy
    Sanchez Caballero, Juan Carlos
    Centurion, Virgilio
    REVISTA BRASILEIRA DE OFTALMOLOGIA, 2013, 72 (02) : 103 - 107
  • [29] Intraocular lens power calculation after radial keratotomy: Estimating the refractive corneal power
    Awwad, Shady T.
    Dwarakanathan, Surendar
    Bowman, R. Wayne
    Cavanagh, H. Dwight
    Verity, Steven M.
    Mootha, Vinod V.
    McCulley, James P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (06): : 1045 - 1050
  • [30] ASCRS calculator formula accuracy in multifocal intraocular lens implantation in hyperopic corneal refractive laser surgery eyes
    Vrijman, Violette
    Abulafia, Adi
    van der Linden, Jan Willem
    van der Meulen, Ivanka J. E.
    Mourits, Maarten P.
    Lapid-Gortzak, Ruth
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (05): : 582 - 586