A Multichannel System for Continuous Measurements of Skin Resistance and Capacitance at Acupuncture Points

被引:28
作者
Colbert, Agatha P. [1 ]
Larsen, Adrian [2 ]
Chamberlin, Steve [1 ]
Decker, Carrie [1 ]
Schiffke, Heather C. [1 ]
Gregory, William L. [1 ]
Thong, Tran [1 ]
机构
[1] Helfgott Res Inst, Natl Coll Nat Med, Portland, OR 97201 USA
[2] Miridia Technology Inc, Meridian, ID USA
基金
美国国家卫生研究院;
关键词
capacitance; physiological marker; skin resistance; step voltage response;
D O I
10.1016/S2005-2901(09)60066-2
中图分类号
R [医药、卫生];
学科分类号
10 ;
摘要
Electrodermal screening (EDS) is based on three commonly held assumptions: acupuncture points (APs) have lower electrical resistance than non-APs; resistance at APs varies with health and disease; and effective acupuncture treatments are associated with normalization of resistance at APs. Although evidence confirming these assumptions is limited, EDS is frequently practiced worldwide. Researchers are also beginning to assess EDS' utility as an outcome measure in acupuncture trials. Fundamental in developing EDS as a research tool is the need for an accurate and reliable measurement. We developed an automated multichannel prototype system, the Octopus, and recorded electrical resistance and capacitance at eight skin sites in 33 healthy participants over 2 hours. The Octopus accurately measured against known resistors (within 2.5% of the mean value) and capacitors (within 10% of the mean value), and yielded repeatable readings at all eight skin sites: LR 1 (r = 0.79), SP 1 (r = 0.79), toe non-AP (r = 0.77), LU 9 (r = 0.97), PC 6 (r = 0.96), wrist non-APs (r = 0.97), SP 6 (r = 0.96), and leg non-APs (r = 0.97). Resistance at APs was significantly lower than the nearby non-APs in one out of three comparisons.
引用
收藏
页码:259 / 268
页数:10
相关论文
共 33 条
[1]  
Ahn A, 2009, J ALTERN COMPLEMENT
[2]   Electrical properties of acupuncture points and meridians: A systematic review [J].
Ahn, Andrew C. ;
Colbert, Agatha P. ;
Anderson, Belinda J. ;
Martinsen, Orjan G. ;
Hammerschlag, Richard ;
Cina, Steve ;
Wayne, Peter M. ;
Langevin, Helene M. .
BIOELECTROMAGNETICS, 2008, 29 (04) :245-256
[3]   Electrical characterization of acupuncture points: Technical issues and challenges [J].
Ahn, Andrew C. ;
Martinsen, Orjan G. .
JOURNAL OF ALTERNATIVE AND COMPLEMENTARY MEDICINE, 2007, 13 (08) :817-824
[4]   Electrical impedance along connective tissue planes associated with acupuncture meridians [J].
Ahn A.C. ;
Wu J. ;
Badger G.J. ;
Hammerschlag R. ;
Langevin H.M. .
BMC Complementary and Alternative Medicine, 5 (1)
[5]  
Cho Sang-Hyun, 1994, Yonsei Medical Journal, V35, P464
[6]   Skin Impedance Measurements for Acupuncture Research: Development of a Continuous Recording System [J].
Colbert, Agatha P. ;
Yun, Jinkook ;
Larsen, Adrian ;
Edinger, Tracy ;
Gregory, William L. ;
Thong, Tran .
EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE, 2008, 5 (04) :443-450
[7]  
Colbert AP, 2004, J ALTERN COMPLEM MED, V10, P610
[8]  
COLBERT AP, 2006, MED ACUPUNCTURE, V17, P12
[9]  
Halek J, 1984, Acta Univ Palacki Olomuc Fac Med, V107, P51
[10]  
JAKOUBEK B, 1982, PHYSIOL BOHEMOSLOV, V31, P143