Influence of optic disc size on the diagnostic performance of macular ganglion cell complex and peripapillary retinal nerve fiber layer analyses in glaucoma

被引:20
作者
Cordeiro, Daniela Valenca [1 ]
Lima, Veronica Castro [1 ,2 ]
Castro, Dinorah P. [1 ,3 ]
Castro, Leonardo C. [1 ,3 ]
Pacheco, Maria Angelica [2 ]
Lee, Jae Min [2 ]
Dimantas, Marcelo I. [2 ]
Prata, Tiago Santos [1 ,2 ]
机构
[1] Univ Fed Sao Paulo, Dept Ophthalmol, Sao Paulo, Brazil
[2] Hosp Medicina Olhos, Sao Paulo, Brazil
[3] Ctr Brasileiro Especialidades Oftalmolog, Araraquara, Brazil
关键词
glaucoma; retinal nerve fiber layer; optical coherence tomography; ganglion cell complex;
D O I
10.2147/OPTH.S20893
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To evaluate the influence of optic disc size on the diagnostic accuracy of macular ganglion cell complex (GCC) and conventional peripapillary retinal nerve fiber layer (pRNFL) analyses provided by spectral domain optical coherence tomography (SD-OCT) in glaucoma. Methods: Eighty-two glaucoma patients and 30 healthy subjects were included. All patients underwent GCC (7 x 7 mm macular grid, consisting of RNFL, ganglion cell and inner plexiform layers) and pRNFL thickness measurement (3.45 mm circular scan) by SD-OCT. One eye was randomly selected for analysis. Initially, receiver operating characteristic (ROC) curves were generated for different GCC and pRNFL parameters. The effect of disc area on the diagnostic accuracy of these parameters was evaluated using a logistic ROC regression model. Subsequently, 1.5, 2.0, and 2.5 mm(2) disc sizes were arbitrarily chosen (based on data distribution) and the predicted areas under the ROC curves (AUCs) and sensitivities were compared at fixed specificities for each. Results: Average mean deviation index for glaucomatous eyes was -5.3 +/- 5.2 dB. Similar AUCs were found for the best pRNFL (average thickness = 0.872) and GCC parameters (average thickness = 0.824; P = 0.19). The coefficient representing disc area in the ROC regression model was not statistically significant for average pRNFL thickness (-0.176) or average GCC thickness (0.088; P > 0.56). AUCs for fixed disc areas (1.5, 2.0, and 2.5 mm(2)) were 0.904, 0.891, and 0.875 for average pRNFL thickness and 0.834, 0.842, and 0.851 for average GCC thickness, respectively. The highest sensitivities - at 80% specificity for average pRNFL (84.5%) and GCC thicknesses (74.5%) - were found with disc sizes fixed at 1.5 mm(2) and 2.5 mm(2). Conclusion: Diagnostic accuracy was similar between pRNFL and GCC thickness parameters. Although not statistically significant, there was a trend for a better diagnostic accuracy of pRNFL thickness measurement in cases of smaller discs. For GCC analysis, an inverse effect was observed.
引用
收藏
页码:1333 / 1337
页数:5
相关论文
共 19 条
[1]   Comparison between GDx VCC scanning laser polarimetry and Stratus OCT optical coherence tomography in the diagnosis of chronic glaucoma [J].
Brusini, Paolo ;
Salvetat, Maria L. ;
Zeppieri, Marco ;
Tosoni, Claudia ;
Parisi, Lucia ;
Felletti, Mirella .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2006, 84 (05) :650-655
[2]   Spectral domain optical coherence tomography - Ultra-high speed, ultra-high resolution ophthalmic imaging [J].
Chen, TC ;
Cense, B ;
Pierce, MC ;
Nassif, N ;
Park, BH ;
Yun, SH ;
White, BR ;
Bouma, BE ;
Tearney, GJ ;
de Boer, JF .
ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (12) :1715-1720
[3]   Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography [J].
de Boer, JF ;
Cense, B ;
Park, BH ;
Pierce, MC ;
Tearney, GJ ;
Bouma, BE .
OPTICS LETTERS, 2003, 28 (21) :2067-2069
[4]   Diagnostic accuracy of nerve fibre layer, macular thickness and optic disc measurements made with the RTVue-100 optical coherence tomograph to detect glaucoma [J].
Garas, A. ;
Vargha, P. ;
Hollo, G. .
EYE, 2011, 25 (01) :57-65
[5]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[6]   Evaluation of the glaucomatous damage on retinal nerve fiber layer thickness measured by optical coherence tomography [J].
Kanamori, A ;
Nakamura, M ;
Escano, MFT ;
Seya, R ;
Maeda, H ;
Negi, A .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (04) :513-520
[7]   Structure-Function Relationship and Diagnostic Value of Macular Ganglion Cell Complex Measurement Using Fourier-Domain OCT in Glaucoma [J].
Kim, Na Rae ;
Lee, Eun Suk ;
Seong, Gong Je ;
Kim, Ji Hyun ;
An, Hyong Gin ;
Kim, Chan Yun .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (09) :4646-4651
[8]   Analysis of macular volume in normal and glaucomatous eyes using optical coherence tomography [J].
Lederer, DE ;
Schuman, JS ;
Hertzmark, E ;
Heltzer, J ;
Velazques, LJ ;
Fujimoto, JG ;
Mattox, C .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (06) :838-843
[9]   Comparison of macular and peripapillary measurements for the detection of glaucoma - An optical coherence tomography study [J].
Leung, CKS ;
Chan, WM ;
Yung, WH ;
Ng, ACK ;
Woo, J ;
Tsang, MK ;
Tse, RKK .
OPHTHALMOLOGY, 2005, 112 (03) :391-400
[10]   Influence of disease severity and optic disc size on the diagnostic performance of imaging instruments in glaucoma [J].
Medeiros, FA ;
Zangwill, LM ;
Bowd, C ;
Sample, PA ;
Weinreb, RN .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (03) :1008-1015