Cortical and Standard Trajectory Pedicle Screw Fixation Techniques in Stabilizing Multisegment Lumbar Spine with Low Grade Spondylolisthesis

被引:13
作者
Cheng, Wayne K. [1 ]
Inceoglu, Serkan [1 ]
机构
[1] Loma Linda Univ, Sch Med, Dept Orthopaed Surg, East Campus Ambulatory Serv Bldg, Loma Linda, CA 92354 USA
来源
INTERNATIONAL JOURNAL OF SPINE SURGERY | 2015年 / 9卷
关键词
CORTICAL BONE TRAJECTORY; PEDICLE SCREW; CORTICAL SCREW; LUMBAR SPINE; LOW GRADE SPONDYLOLISTHESIS MODEL; BIOMECHANICS;
D O I
10.14444/2046
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Cortical screw (CS) fixation has been recently proposed as an alternative to the standard pedicle screw (PS) fixation technique. Biomechanical studies involving individual screw pullout and single level motion segment stabilization showed comparable performance of both techniques. However, whether this new fixation technique can be applied to the stabilization of multilevel lumbar segments with significant destabilization has been unclear. Purpose To compare stability of CS fixation to the traditional PS fixation in an unstable 3 level spondylolisthesis model. Study Design This is a biomechanical study comparing cortical trajectory pedicle screw fixation to traditional trajectory pedicle screw fixation in an unstable cadaveric model using nondestructive flexibility test. Methods Eight fresh frozen cadaveric lumbar spines (T12-S1) were obtained. After intact baseline testing, a 3-level low-grade spondylolisthesis was simulated at the L1-4. Each specimen was instrumented with the PS and CS fixation systems. Standard nondestructive flexibility test was performed. Range of motion at each level was compared between the constructs during flexion-extension, lateral bending, and axial rotation. Results The destabilization model significantly increased the ROM in all planes (P<0.05). Both fixation techniques provided significant reduction in the ROM (P<0.05). There was no significant difference in ROM between the PS and CS groups in any of planes (P>0.05). Conclusions Cortical trajectory pedicle screw fixation provided stabilization to multilevel lumbar segment with low-grade spondylolisthesis comparable to the standard trajectory pedicle screw construct.
引用
收藏
页数:8
相关论文
共 18 条
  • [11] Influence of the screw augmentation technique and a diameter increase on pedicle screw fixation in the osteoporotic spine: pullout versus fatigue testing
    Kueny, Rebecca A.
    Kolb, Jan P.
    Lehmann, Wolfgang
    Pueschel, Klaus
    Morlock, Michael M.
    Huber, Gerd
    [J]. EUROPEAN SPINE JOURNAL, 2014, 23 (10) : 2196 - 2202
  • [12] Effect of osteoarthritis in the lumbar spine and hip on bone mineral density and diagnosis of osteoporosis in elderly men and women
    Liu, G
    Peacock, M
    Eilam, O
    Dorulla, G
    Braunstein, E
    Johnston, CC
    [J]. OSTEOPOROSIS INTERNATIONAL, 1997, 7 (06) : 564 - 569
  • [13] MAGERL FP, 1984, CLIN ORTHOP RELAT R, P125
  • [14] Morphometric Measurement of Cortical Bone Trajectory for Lumbar Pedicle Screw Insertion Using Computed Tomography
    Matsukawa, Keitaro
    Yato, Yoshiyuki
    Nemoto, Osamu
    Imabayashi, Hideaki
    Asazuma, Takashi
    Nemoto, Koichi
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2013, 26 (06): : E248 - E253
  • [15] Biomechanics of Lumbar Cortical Screw-Rod Fixation Versus Pedicle Screw-Rod Fixation With and Without Interbody Support
    Perez-Orribo, Luis
    Kalb, Samuel
    Reyes, Phillip M.
    Chang, Steve W.
    Crawford, Neil R.
    [J]. SPINE, 2013, 38 (08) : 635 - 641
  • [16] ROYCAMILLE R, 1976, RECONS SURG, V15, P2
  • [17] Cortical bone trajectory for lumbar pedicle screws
    Santoni, B. G.
    Hynes, R. A.
    McGilvray, K. C.
    Rodriguez-Canessa, G.
    Lyons, A. S.
    Henson, M. A. W.
    Womack, W. J.
    Puttlitz, C. M.
    [J]. SPINE JOURNAL, 2009, 9 (05) : 366 - 373
  • [18] Biornechanical analysis of differing pedicle screw insertion angles
    Sterba, William
    Kim, Do-Gyoon
    Fyhrie, David P.
    Yeni, Yener N.
    Vaidya, Rahul
    [J]. CLINICAL BIOMECHANICS, 2007, 22 (04) : 385 - 391