Cortical and Standard Trajectory Pedicle Screw Fixation Techniques in Stabilizing Multisegment Lumbar Spine with Low Grade Spondylolisthesis

被引:13
作者
Cheng, Wayne K. [1 ]
Inceoglu, Serkan [1 ]
机构
[1] Loma Linda Univ, Sch Med, Dept Orthopaed Surg, East Campus Ambulatory Serv Bldg, Loma Linda, CA 92354 USA
来源
INTERNATIONAL JOURNAL OF SPINE SURGERY | 2015年 / 9卷
关键词
CORTICAL BONE TRAJECTORY; PEDICLE SCREW; CORTICAL SCREW; LUMBAR SPINE; LOW GRADE SPONDYLOLISTHESIS MODEL; BIOMECHANICS;
D O I
10.14444/2046
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Cortical screw (CS) fixation has been recently proposed as an alternative to the standard pedicle screw (PS) fixation technique. Biomechanical studies involving individual screw pullout and single level motion segment stabilization showed comparable performance of both techniques. However, whether this new fixation technique can be applied to the stabilization of multilevel lumbar segments with significant destabilization has been unclear. Purpose To compare stability of CS fixation to the traditional PS fixation in an unstable 3 level spondylolisthesis model. Study Design This is a biomechanical study comparing cortical trajectory pedicle screw fixation to traditional trajectory pedicle screw fixation in an unstable cadaveric model using nondestructive flexibility test. Methods Eight fresh frozen cadaveric lumbar spines (T12-S1) were obtained. After intact baseline testing, a 3-level low-grade spondylolisthesis was simulated at the L1-4. Each specimen was instrumented with the PS and CS fixation systems. Standard nondestructive flexibility test was performed. Range of motion at each level was compared between the constructs during flexion-extension, lateral bending, and axial rotation. Results The destabilization model significantly increased the ROM in all planes (P<0.05). Both fixation techniques provided significant reduction in the ROM (P<0.05). There was no significant difference in ROM between the PS and CS groups in any of planes (P>0.05). Conclusions Cortical trajectory pedicle screw fixation provided stabilization to multilevel lumbar segment with low-grade spondylolisthesis comparable to the standard trajectory pedicle screw construct.
引用
收藏
页数:8
相关论文
共 18 条
  • [1] Barber JW, 1998, J SPINAL DISORD, V11, P215
  • [2] In vitro, biomechanical comparison of an anterior lumbar interbody fusion with an anteriorly placed, low-profile lumbar plate and posteriorly placed pedicle screws or translaminar screws
    Beaubien, BP
    Derincek, A
    Lew, WD
    Wood, KB
    [J]. SPINE, 2005, 30 (16) : 1846 - 1851
  • [3] BOUCHER HH, 1959, J BONE JOINT SURG BR, V41, P248
  • [4] Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design
    Cook, SD
    Salkeld, SL
    Whitecloud, TS
    Barbera, J
    [J]. JOURNAL OF SPINAL DISORDERS, 2000, 13 (03): : 230 - 236
  • [5] Cook Stephen D, 2004, Spine J, V4, P402, DOI 10.1016/j.spinee.2003.11.010
  • [6] Trajectory analysis and pullout strength of self-centering lumbar pedicle screws
    Crawford, Neil R.
    Yueksel, K. Zafer
    Dogan, Seref
    Villasana-Ramos, Octavio
    Soto-Barraza, Julio C.
    Baek, Seungwon
    Porter, Randall W.
    Marciano, Frederick F.
    Theodore, Nicholas
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2009, 10 (05) : 486 - 491
  • [7] Biomechanics of Grade I degenerative lumbar spondylolisthesis.: Part 1:: In vitro model
    Crawford, NR
    Çagli, S
    Sonntag, VKH
    Dickman, CA
    [J]. JOURNAL OF NEUROSURGERY, 2001, 94 (01) : 45 - 50
  • [8] Biomechanical evaluation of lumbosacral reconstruction techniques for spondylolisthesis -: An in vitro porcine model
    Cunningham, BW
    Lewis, SJ
    Long, J
    Dmitriev, AE
    Linville, DA
    Bridwell, KH
    [J]. SPINE, 2002, 27 (21) : 2321 - 2327
  • [9] Transforaminal lumbar interbody fusion - The effect of various instrumentation techniques on the flexibility of the lumbar spine
    Harris, BM
    Hilibrand, AS
    Savas, PE
    Pellegrino, A
    Vaccaro, AR
    Siegler, S
    Albert, TJ
    [J]. SPINE, 2004, 29 (04) : E65 - E70
  • [10] Pedicle screw insertion angle and pullout strength: comparison of 2 proposed strategies
    Inceoglu, Serkan
    Montgomery, William H., Jr.
    St Clair, Selvon
    McLain, Robert F.
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2011, 14 (05) : 670 - 676