ONLINE PRECONCENTRATION AND DETERMINATION OF TRACE-ELEMENTS BY FLOW-INJECTION INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY

被引:87
作者
CAROLI, S [1 ]
ALIMONTI, A [1 ]
PETRUCCI, F [1 ]
HORVATH, Z [1 ]
机构
[1] EOTVOS LORAND UNIV, INST INORGAN & ANALYT CHEM, H-1518 BUDAPEST 112, HUNGARY
关键词
EMISSION SPECTROMETRY; FLOW SYSTEM; PLASMAS; PRECONCENTRATION; SEA WATER; TRACE METALS; URINE; WATERS;
D O I
10.1016/S0003-2670(00)80891-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A study was made of the capabilities of iminodiacetic acid/ethylcellulose (IDAEC) to serve as the chelating resin for preconcentrating trace elements together with a computer-assisted on-line flow injection analysis-inductively coupled plasma atomic emission spectrometry technique. The system was tested with a few analytes of particular clinical and environmental importance (Cd, Co, Cu and Pb) in matrices such as water, sea water and urine. The performance of IDAEC resin was compared with that of carboxymethylated polyethyleneimine-polymethylenepolyphenylene isocyanate (CPPI) and Chelex 100 with regard to enrichment factor, analytical throughput and recovery. With several obvious advantages over the batch procedure, the on-line mode improved the detection power by one to two orders of magnitude and allowed twelve samples per hour to be treated. IDAEC appears to be the most convenient resin in terms of efficiency and long-term performance.
引用
收藏
页码:241 / 249
页数:9
相关论文
共 15 条
[1]   TRACE ENRICHMENT AND DETERMINATION OF SULFATE BY FLOW-INJECTION INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
COX, AG ;
MCLEOD, CW ;
MILES, DL ;
COOK, JM .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1987, 2 (06) :553-555
[2]  
DOUGLAS DJ, 1985, PROG ANAL ATOM SPECT, V8, P1
[3]   FUNDAMENTAL AND PRACTICAL CONSIDERATIONS IN THE DESIGN OF ONLINE COLUMN PRECONCENTRATION FOR FLOW-INJECTION ATOMIC SPECTROMETRIC SYSTEMS [J].
FANG, ZL ;
XU, SK ;
ZHANG, SC .
ANALYTICA CHIMICA ACTA, 1987, 200 (01) :35-49
[5]   INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION-SPECTROSCOPY (ICP-AES) WITH FLOW-INJECTION ANALYSIS (FIA) [J].
GREENFIELD, S .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1983, 38 (1-2) :93-105
[6]   SENSITIVITY ENHANCEMENTS FOR FLOW-INJECTION ANALYSIS INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY USING AN ONLINE PRECONCENTRATING ION-EXCHANGE COLUMN [J].
HARTENSTEIN, SD ;
RUZICKA, J ;
CHRISTIAN, GD .
ANALYTICAL CHEMISTRY, 1985, 57 (01) :21-25
[7]   COLUMN PACKED WITH ION-EXCHANGE CELLULOSE LOOSE FIBERS FOR PRODUCTION OF HIGH-PURITY WATER [J].
HORVATH, Z ;
LASZTITY, A ;
SZAKACS, O .
ANALYTICAL CHEMISTRY, 1981, 53 (07) :1149-1150
[8]   CARBOXYMETHYLATED POLYETHYLENIMINE POLYMETHYLENEPOLYPHENYLENE ISOCYANATE CHELATING ION-EXCHANGE RESIN PRECONCENTRATION FOR INDUCTIVELY COUPLED PLASMA SPECTROMETRY [J].
HORVATH, Z ;
BARNES, RM .
ANALYTICAL CHEMISTRY, 1986, 58 (07) :1352-1355
[9]  
HORVATH Z, 1975, J INORG NUCL CHEM, V37, P767, DOI 10.1016/0022-1902(75)80536-7
[10]   IMINODIACETIC ACID ETHYLCELLULOSE AS A CHELATING ION-EXCHANGER .2. DETERMINATION OF TRACE-METALS BY INDUCTIVELY-COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
HORVATH, Z ;
BARNES, RM ;
MURTY, PS .
ANALYTICA CHIMICA ACTA, 1985, 173 (JUL) :305-309