A FLUOROSCOPY-BASED COMPUTED-TOMOGRAPHY SCANNER FOR SMALL SPECIMEN RESEARCH

被引:6
作者
BOONE, JM
ALEXANDER, GM
SEIBERT, JA
机构
[1] TEMPLE UNIV,DEPT RADIOL,PHILADELPHIA,PA 19122
[2] TEMPLE UNIV,DEPT NEUROL,PHILADELPHIA,PA 19122
关键词
COMPUTED TOMOGRAPHY; ANIMAL RESEARCH; DIGITAL IMAGING;
D O I
10.1097/00004424-199306000-00015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. A small-laboratory computed tomography (CT) system using a fluoroscopic system and a personal computer was fabricated and tested. The motivation for building this specimen scanner was to provide medical researchers with the capability of using CT as a practical tool in their research, as well as to provide an opportunity for hands-on CT instruction. METHODS AND MATERIALS. The CT system was constructed using mostly off-the-shelf items; however, the CT stage itself was custom fabricated and software development was necessary. In addition, a personal computer and a standard fluoroscopy system were used. RESULTS. The spatial resolution was found to match the 228-mum sampling limitation, yielding approximately 2 line pairs per mm. Iodine contrast sensitivity studies showed that 1% solution of 370 mg/ml iodine solution was easily detected (P almost-equal-to .05). CONCLUSIONS. A small CT scanner for specimen research can be economically constructed, and is capable of good performance. The authors found substantial interest on the part of small animal researchers involved in a wide variety of medical research.
引用
收藏
页码:539 / 544
页数:6
相关论文
共 10 条
[1]   RADIONUCLIDE EMISSION COMPUTED TOMOGRAPHY OF BODY OF LABORATORY-ANIMALS [J].
HILL, TC ;
COSTELLO, P ;
DAVIS, MA ;
LOVETT, R ;
SHULKIN, P .
RADIOLOGY, 1978, 128 (03) :799-801
[2]  
HOLDSWORTH DW, 1990, P SOC PHOTO-OPT INS, V1231, P239, DOI 10.1117/12.18801
[3]   HIGH-RESOLUTION COMPUTED-TOMOGRAPHY OF THE NORMAL RAT NEPHROGRAM [J].
KUJOORY, MA ;
HILLMAN, BJ ;
BARRETT, HH .
INVESTIGATIVE RADIOLOGY, 1980, 15 (02) :148-154
[4]   A SPECIAL PURPOSE X-RAY FAN-BEAM CT SCANNER FOR TRABECULAR BONE-DENSITY MEASUREMENT IN THE APPENDICULAR SKELETON [J].
MCCLEAN, BA ;
OVERTON, TR ;
HANGARTNER, TN ;
RATHEE, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (01) :11-19
[5]   COMPUTER-SIMULATION OF IMAGE INTENSIFIER-BASED COMPUTED-TOMOGRAPHY DETECTOR - VASCULAR APPLICATION [J].
NING, R ;
KRUGER, RA .
MEDICAL PHYSICS, 1988, 15 (02) :188-192
[6]  
OHAZAKI T, 1992, RADIOLOGY, V185, P394
[7]   COMPUTED-TOMOGRAPHY FROM ORDINARY RADIOGRAPHS FOR TELERADIOLOGY [J].
RANGAYYAN, RM ;
GORDON, R .
MEDICAL PHYSICS, 1983, 10 (05) :687-690
[8]   A 4-MV CT SCANNER FOR RADIATION-THERAPY - SPECTRAL PROPERTIES OF THE THERAPY BEAM [J].
SWINDELL, W .
MEDICAL PHYSICS, 1983, 10 (03) :347-351
[9]   A LOW-COST COMPUTED TOMOGRAPHIC SCANNER [J].
SWINDELL, W ;
GREIVENKAMP, JE ;
GMITRO, AF ;
BARRETT, HH .
RADIOLOGY, 1981, 139 (02) :499-501
[10]  
SWINDELL W, 1988, PHYSICS MED IMAGING, P117