AUTOMATIC POTENTIOMETRIC DETERMINATION OF DISSOLVED-OXYGEN

被引:63
作者
GRANELI, W [1 ]
GRANELI, E [1 ]
机构
[1] UNIV LUND,DEPT ECOL MARINE ECOL,S-22100 LUND,SWEDEN
关键词
PRECISE SHIPBOARD DETERMINATION; WINKLER PROCEDURE; COMMUNITY PRODUCTION; COMMERCIAL SYSTEM; RESPIRATION; TITRATION; ELECTRODE; ACCURACY; LAKES; OCEAN;
D O I
10.1007/BF01344349
中图分类号
Q17 [水生生物学];
学科分类号
071004 ;
摘要
Commercially available automatic titration systems were tested in 1988 for potentiometric titration of liberated iodine by the Winkler method of oxygen determination. The potentiometric equivalence point was also compared to the manual starch end point. Finally the automatic method was used in order to estimate below-halocline respiration in the Kattegat, Sweden. Standard deviations of 0.007 ml O2 l-1 or 0.1 to 0.3% coefficients of variation (% standard deviation of the mean) were achieved when titrating 25 ml from replicate 60-ml oxygen bottles using the automatic method, or 50 ml manually. The precision for replicate titrations of 50-ml aliquots of 0.001 N KIO3 was < 0.05% (0.002 ml 0.01 N Na2S2O3) for the automatic method. Titration time for 25-ml aliquots was 2 to 4 min, somewhat longer than for manual titrations (1 to 1.5 min). However, during titration the operator is free to perform other tasks. It is not possible to use automatic sample changers, due to rapid iodine volatilization. The equipment can be handled by relatively unskilled analysts and is suitable for use on board research vessels or in field stations [weight for a Mettler(TM) titrator (Mettler Instrumente AG, Greifensee, Switzerland) < 10 kg, volume < 0.1 m3]. Below-halocline oxygen consumption in the SE Kattegat ranged from 0 to 6 ml O2 m-3 h-1 (mean values for September and October 1988 = 1.69 and 0.66 ml O2 m-3 h-1, respectively, with 95% confidence limits of ca. +/- 0.6 ml O2 m-3 h-1).
引用
收藏
页码:341 / 348
页数:8
相关论文
共 30 条
[2]   FAST-RESPONSE OXYGEN SENSOR FOR A FREE-FALL CTD [J].
ATKINSON, MJ .
LIMNOLOGY AND OCEANOGRAPHY, 1988, 33 (01) :141-145
[3]   COMPARISON OF POLAROGRAPHIC ELECTRODE AND WINKLER TITRATION DETERMINATIONS OF DISSOLVED-OXYGEN IN OCEANOGRAPHIC SAMPLES [J].
ATWOOD, DK ;
KINARD, WF ;
BARCELONA, MJ ;
JOHNSON, EC .
DEEP-SEA RESEARCH, 1977, 24 (03) :311-313
[4]   A COMPARISON OF 4 METHODS FOR DETERMINING PLANKTONIC COMMUNITY PRODUCTION [J].
BENDER, M ;
GRANDE, K ;
JOHNSON, K ;
MARRA, J ;
WILLIAMS, PJL ;
SIEBURTH, J ;
PILSON, M ;
LANGDON, C ;
HITCHCOCK, G ;
ORCHARDO, J ;
HUNT, C ;
DONAGHAY, P ;
HEINEMANN, K .
LIMNOLOGY AND OCEANOGRAPHY, 1987, 32 (05) :1085-1098
[5]   WINKLER PROCEDURE FOR MAKING PRECISE MEASUREMENTS OF OXYGEN CONCENTRATION FOR PRODUCTIVITY AND RELATED STUDIES [J].
BRYAN, JR ;
RILEY, JP ;
WILLIAMS, PJL .
JOURNAL OF EXPERIMENTAL MARINE BIOLOGY AND ECOLOGY, 1976, 21 (03) :191-197
[6]  
CARPENTER JAMES H., 1965, LIMNOL OCEANOGR, V10, P135
[7]  
CARPENTER JAMES H., 1965, LIMNOL OCEANOGR, V10, P141
[8]   RESPIRATORY ELECTRON-TRANSPORT ACTIVITIES IN PHYTOPLANKTON AND BACTERIA - COMPARISON OF METHODS [J].
CHRISTENSEN, JP ;
PACKARD, TT .
LIMNOLOGY AND OCEANOGRAPHY, 1979, 24 (03) :576-583
[9]   SIMPLE METHOD OF MEASURING SESTON RESPIRATION IN OLIGOTROPHIC LAKES [J].
CORNETT, RJ ;
RIGLER, FH .
CANADIAN JOURNAL OF FISHERIES AND AQUATIC SCIENCES, 1986, 43 (08) :1660-1663
[10]   AUTOMATED AMPEROMETRIC OXYGEN TITRATION [J].
CULBERSON, CH ;
HUANG, S .
DEEP-SEA RESEARCH PART A-OCEANOGRAPHIC RESEARCH PAPERS, 1987, 34 (5-6) :875-880