AMPEROMETRIC DETECTION OF PEROXIDES WITH POLY(ANILINOMETHYLFERROCENE)-MODIFIED ENZYME ELECTRODES

被引:71
作者
MULCHANDANI, A [1 ]
WANG, CL [1 ]
WEETALL, HH [1 ]
机构
[1] NIST,DIV BIOTECHNOL,GAITHERSBURG,MD 20899
关键词
D O I
10.1021/ac00097a016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric enzyme electrode employing covalently attached horseradish peroxidase to glassy carbon electrode and a ferrocene-modified polyaniline film deposited by the electrochemical polymerization of N-(ferrocenylmethyl)aniline monomer is reported. The electrode responded rapidly to micromolar concentrations of peroxides, in accordance with the following trend: hydrogen peroxide > cumene hydroperoxide > tert-butyl hydroperoxide. The effect of operational parameters, such as methods of enzyme immobilization, operating potential of the working electrode, pH, and effect of molecular oxygen, were explored for optimum analytical performance. The dynamic properties of this enzyme electrode were exploited for the detection in now injection analysis. Applicability of the enzyme electrode for measurement of peroxide in real sample was demonstrated.
引用
收藏
页码:94 / 100
页数:7
相关论文
共 50 条
[31]   Tetralactam-modified gold electrodes for amperometric detection of acrylic acid [J].
Krajewska, A. ;
Smet, M. ;
Dehaen, W. ;
Radecka, H. .
SUPRAMOLECULAR CHEMISTRY, 2009, 21 (06) :520-531
[32]   PEDOT/PVC-modified amperometric carbon electrodes for acetylcholine detection [J].
Xu, Peibo ;
Muhamad Rapidi, Hazirah Ismah ;
Ahmed, Sidrah ;
Abel, Daniel Kenneth ;
Garcia, Kiersten Jade ;
Chen, Ran ;
Iwai, Nicholas Toshio ;
Shen, Mei .
CHEMICAL COMMUNICATIONS, 2022, 58 (95) :13218-13221
[33]   Highly sensitive amperometric enzyme biosensor for detection of superoxide based on conducting polymer/CNT modified electrodes and superoxide dismutase [J].
Braik, Mourad ;
Barsan, Madalina M. ;
Dridi, Cherif ;
Ben Ali, Mounir ;
Brett, Christopher M. A. .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 236 :574-582
[34]   Poly-L-lysine-modified boron-doped diamond electrodes for the amperometric detection of nucleic acid bases [J].
Niedzialkowski, P. ;
Ossowski, T. ;
Zieba, P. ;
Cirocka, A. ;
Rochowski, P. ;
Pogorzelski, S. J. ;
Ryl, J. ;
Sobaszek, M. ;
Bogdanowicz, R. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 756 :84-93
[35]   Amperometric enzyme electrode for organic peroxides determination prepared from horseradish peroxidase immobilized in poly(vinylferrocenium) film [J].
Gündogan-Paul, M ;
Çelebi, SS ;
Özyörük, H ;
Yildiz, A .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (10) :875-881
[36]   Flow injection amperometric detection at enzyme-modified gold nanoelectrodes [J].
Delvaux, M ;
Demoustier-Champagne, S ;
Walcarius, A .
ELECTROANALYSIS, 2004, 16 (03) :190-198
[37]   Electrosynthesis of a new enzyme-modified electrode for the amperometric detection of glucose [J].
Piro, B ;
Do, VA ;
Le, LA ;
Hedayatullah, M ;
Pham, MC .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2000, 486 (02) :133-140
[38]   FERROCENE-CONJUGATED POLYANILINE-MODIFIED ENZYME ELECTRODES FOR DETERMINATION OF PEROXIDES IN ORGANIC MEDIA [J].
WANG, CL ;
MULCHANDANI, A .
ANALYTICAL CHEMISTRY, 1995, 67 (06) :1109-1114
[39]   Determination of peroxides by capillary zone electrophoresis with amperometric detection [J].
Rüttinger, HH ;
Radschuweit, A .
JOURNAL OF CHROMATOGRAPHY A, 2000, 868 (01) :127-134
[40]   NEW AMPEROMETRIC DEHYDROGENASE ELECTRODES BASED ON ELECTROCATALYTIC NADH-OXIDATION AT POLY(METHYLENE BLUE)-MODIFIED ELECTRODES [J].
KARYAKIN, AA ;
KARYAKINA, EE ;
SCHUHMANN, W ;
SCHMIDT, HL ;
VARFOLOMEYEV, SD .
ELECTROANALYSIS, 1994, 6 (10) :821-829