Hemoglobin A1C determination by point-of-care testing: Its correlation to standard method

被引:3
|
作者
Wiwanitkit, Viroj [1 ,2 ]
机构
[1] Hainan Med Univ, Haikou, Hainan, Peoples R China
[2] Joseph Ayobabalola Univ, Ilara Mokin, Nigeria
关键词
Hemoglobin A1C; Point-of-care testing;
D O I
10.1016/j.dsx.2012.08.014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The hemoglobin A1C (HbA1C) is the useful test for following up of glycemic control of the diabetic patient. Due to the present advance in point-of-care testing (POCT) technology, the new POCT for determination of HbA1C is available. Here, the author performs a laboratory comparative study between the new POCT tool (DCA) and classical tool (COBAS) for analysis of HbA1C level. This study is the second confirmation study in Thailand performed in the new setting adding to the previous author's report. The results show that there is a good correlation between two techniques and the error of the POCT tool is within acceptable limit. (C) 2012 Diabetes India. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:110 / 111
页数:2
相关论文
共 50 条
  • [21] Point-of-Care Hemoglobin A1C Testing System in Community Settings: Challenges, Opportunities, and Measurement Characteristics
    Smith, Morgan
    Rosenmoss, Sophie
    Seligman, Hilary K.
    PROGRESS IN COMMUNITY HEALTH PARTNERSHIPS-RESEARCH EDUCATION AND ACTION, 2020, 14 (03) : 327 - 335
  • [22] Assessment of Patient Satisfaction with On-Site Point-of-Care Hemoglobin A1c Testing: An Observational Study
    Al Hayek, Ayman A.
    Al-Saeed, Abdulghani H.
    Alzahrani, Wael M.
    Al Dawish, Mohamed A.
    DIABETES THERAPY, 2021, 12 (09) : 2531 - 2544
  • [23] Point-of-care testing for hemoglobin A1c and microalbumin using the BAYER DCA 2000 analyzer.
    Taylor, RL
    Liedtke, R
    Scheidt, R
    Dale, J
    CLINICAL CHEMISTRY, 2001, 47 (06) : A177 - A178
  • [24] Evaluation of the Siemens DCA Vantage hemoglobin A1c point-of-care analyzer
    Charnot-Katsikos, A.
    Hui, S. R.
    Yeo, K. T.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2008, 130 (03) : 481 - 481
  • [25] Accuracy and the Proper Use of the Point-of-Care Analysis in Hemoglobin A1C Measurement
    Lynn, Lei
    Kay, Dana
    Younes, Naji
    Sen, Sabyasachi
    Jain, Vivek
    METABOLIC SYNDROME AND RELATED DISORDERS, 2018, 16 (03) : 117 - 121
  • [26] Are hemoglobin A1c point-of-care analyzers fit for purpose? The story continues
    Lenters-Westra, Erna
    English, Emma
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (04) : 765 - 774
  • [27] Evaluation of the TRIstat point-of-care hemoglobin A1c device versus HPLC
    Shea, E. N.
    Wu, A.
    Wong, A.
    Munoz, V.
    Smith, A. C.
    Midyett, K.
    Garg, U.
    Reddig, N.
    CLINICAL CHEMISTRY, 2008, 54 (06) : A196 - A196
  • [28] Retrospective Accuracy Study of Point-of-Care Hemoglobin A1c in Field Conditions
    Manthei, David M.
    Wesener, Nicholas
    Twarkowski, Denise
    Giacherio, Donald A.
    Schroeder, Lee F.
    CLINICAL CHEMISTRY, 2017, 63 (03) : 780 - 781
  • [29] Discordant Point-of-Care and Laboratory Hemoglobin A1c Concentrations in Ambulatory Settings
    Korpi-Steiner, Nichole
    Cotten, Steven W.
    Little, Randie R.
    Kirk, Deepa
    JOURNAL OF APPLIED LABORATORY MEDICINE, 2024,
  • [30] The Impact of Point-of-Care A1C Testing on Provider Compliance and A1C Levels in a Primary Setting
    Egbunike, Veronica
    Gerard, Sally
    DIABETES EDUCATOR, 2013, 39 (01): : 66 - 73