Performance of emergency physicians utilizing a video-assisted semi-rigid fiberoptic stylet for intubation of a difficult airway in a high-fidelity simulated patient: a pilot study

被引:0
|
作者
Cooney, Derek R. [1 ]
Cooney, Norma L. [2 ]
Wallus, Harry [1 ]
Wojcik, Susan [1 ]
机构
[1] SUNY Upstate Med Univ, Dept Emergency Med, 550 East Genesee EMSTAT Ctr, Syracuse, NY 13202 USA
[2] SUNY Upstate Med Univ, Dept Emergency Med, Syracuse, NY 13210 USA
关键词
Airway; Clarus Video System; difficult; Emergency; Fiberoptic; Laryngoscopy; Levitan; Optical; Shikani; Stylet; StyletScope; Video;
D O I
10.1186/1865-1380-5-24
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: This study was designed to evaluate emergency physician success and satisfaction using a video-assisted semi-rigid fiberoptic stylet, the Clarus Video System (CVS), during a simulated difficult airway scenario. Findings: Emergency physicians (EPs) of all levels were first shown a brief slide show and three example videos, and then given 20 min to practice intubating a mannequin using both the CVS and standard direct laryngoscopy (DL). The mannequin was then placed in a c-collar and set to simulate an apneic patient with an edematous tongue and trismus. Each EP was given up to three timed attempts with each technique. They rated their satisfaction with the CVS, usefulness for their practice, and the effectiveness of the tutorial. Direct laryngoscopy had a 65% success rate on the first attempt, 20% on the second, and 15% required three or more. The CVS had a 100% success rate with a single attempt. Average time for independent DL attempts was 43.41 s (SD = +/- 26.82) and 38.71 s (SD = +/- 34.14) with CVS. Cumulative attempt times were analyzed and compared (DL = 74.55 +/- 68.40 s and CVS = 38.71 +/- 34.14 s; p = 0.028). EPs rated their satisfaction with, and usefulness of, the CVS as >= 6 out of 10. Conclusion: Emergency physicians were able to successfully intubate a simulated difficult airway model on the first attempt 100% of the time. Emergency physicians were satisfied with the CVS and felt that it would be useful in their practice.
引用
收藏
页数:5
相关论文
共 3 条
  • [1] Performance of emergency physicians utilizing a video-assisted semi-rigid fiberoptic stylet for intubation of a difficult airway in a high-fidelity simulated patient: a pilot study
    Derek R Cooney
    Norma L Cooney
    Harry Wallus
    Susan Wojcik
    International Journal of Emergency Medicine, 5 (1)
  • [2] Endotracheal intubation with a video-assisted semi-rigid fiberoptic stylet by prehospital providers
    Cooney D.R.
    Beaudette C.
    Clemency B.M.
    Tanski C.
    Wojcik S.
    International Journal of Emergency Medicine, 2014, 7 (1)
  • [3] Fiberoptic Intubation vs. Video-Assisted Fiberoptic Intubation in a High-Fidelity Pediatric Simulator: A Randomized Controlled Trial
    Isogai, Hatsuo
    Kojima, Taiki
    Kako, Hiromi
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (05)