WASHOUT AND REDISTRIBUTION BETWEEN IMMEDIATE AND 2-HOUR MYOCARDIAL IMAGES USING TC-99M-SESTAMIBI

被引:18
作者
RICHTER, WS
CORDES, M
CALDER, D
EICHSTAEDT, H
FELIX, R
机构
[1] Strahlenklinik und Poliklinik, Universitätsklinikum Rudolf Virchow, Freie Universität Berlin, Berlin, D-13353
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1995年 / 22卷 / 01期
关键词
TC-99M SESTAMIBI; TRACER WASHOUT; TRACER REDISTRIBUTION; EXERCISE STUDIES;
D O I
10.1007/BF00997247
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to assess whether a clinically relevant change in myocardial sestamibi activity could be documented within the first 120 min following injection (p.i.). In 17 patients planar anterior imaging of the heart was performed 5 min and 120 min p.i. During this time interval, mean decay-corrected myocardial activity declined to 77.9%+/-9.7% after stress and to 85.7%+/-7.9% after injection at rest (P<0.05). In 19 patients with angiographically documented coronary artery disease, single-photon emission tomography was performed 5 min and 120 min after injection at maximum stress. For analysis, sestamibi activity was scored semiquantitatively in six left ventricular segments. Furthermore, sestamibi uptake was assessed quantitatively using a circumferential profile method. In 35 of 114 segments the score improved within 120 min p.i. (early fillin); in these segments relative sestamibi activity rose from 69.9%+/-22.5% to 74.5%+/-20.8% (P<0.01). In five patients this early fill-in was the only sign of exercise-induced hypoperfusion. In 7 of 114 segments the score deteriorated 120 min p.i. (early tracer washout); in these segments relative sestamibi activity declined from 85.6%+/-9.9% to 80.1%+/-10.7% (P<0.02). In three of four patients with early tracer washout the corresponding coronary artery was significantly narrowed. In conclusion, a global myocardial sestamibi washout was registered within the first 120 min after injection. A fill-in of initial defects as well as an early tracer loss could be detected in a relevant number of patients with chronic coronary artery disease during the first 2 h p.i. In these patients the extent of detected reversible perfusion abnormality depends on the chosen time interval between injection and imaging. The results of this study suggest that exercise imaging should be started immediately after injection.
引用
收藏
页码:49 / 55
页数:7
相关论文
共 20 条
[1]  
[Anonymous], 1988, ICRP PUBLICATION, V53
[2]  
BROWN KA, 1987, J NUCL MED, V28, P945
[3]  
CUOCOLO A, 1993, EUR J NUCL MED, V20, P1186
[4]  
DAHLBERG ST, 1993, J NUCL MED, V34, P927
[5]   MYOCARDIAL VIABILITY IN PATIENTS WITH CHRONIC CORONARY-ARTERY DISEASE - COMPARISON OF TC-99M-SESTAMIBI WITH THALLIUM REINJECTION AND [F-18] FLUORODEOXYGLUCOSE [J].
DILSIZIAN, V ;
ARRIGHI, JA ;
DIODATI, JG ;
QUYYUMI, AA ;
ALAVI, K ;
BACHARACH, SL ;
MARINNETO, JA ;
KATSIYIANNIS, PT ;
BONOW, RO .
CIRCULATION, 1994, 89 (02) :578-587
[6]  
DILSIZIAN V, 1993, CIRCULATION, V87, P1
[7]   MYOCARDIAL KINETICS OF TC-MIBI IN CANINE MYOCARDIUM AFTER DIPYRIDAMOLE [J].
GLOVER, DK ;
OKADA, RD .
CIRCULATION, 1990, 81 (02) :628-637
[8]   USE OF TECHNETIUM-99M ISONITRILE (RP-30A) IN ASSESSING LEFT-VENTRICULAR PERFUSION AND FUNCTION AT REST AND DURING EXERCISE IN CORONARY-ARTERY DISEASE, AND COMPARISON WITH CORONARY ARTERIOGRAPHY AND EXERCISE TL-201 SPECT IMAGING [J].
ISKANDRIAN, AS ;
HEO, JY ;
KONG, B ;
LYONS, E ;
MARSCH, S .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (05) :270-275
[9]  
JOHANSSON L, 1992, EUR J NUCL MED, V19, P933, DOI 10.1007/BF00175858
[10]   COMPARISON OF TECHNETIUM-99M METHOXY ISOBUTYL ISONITRILE AND TL-201 FOR EVALUATION OF CORONARY-ARTERY DISEASE BY PLANAR AND TOMOGRAPHIC METHODS [J].
KIAT, H ;
MADDAHI, J ;
ROY, LT ;
VANTRAIN, K ;
FRIEDMAN, J ;
RESSER, K ;
BERMAN, DS .
AMERICAN HEART JOURNAL, 1989, 117 (01) :1-11