A 4-ELECTRODE SYSTEM FOR MEASUREMENT OF BILAYER-LIPID MEMBRANE CAPACITANCE

被引:33
|
作者
KALINOWSKI, S
FIGASZEWSKI, Z
机构
[1] Inst. of Chem., Warsaw Univ.
关键词
D O I
10.1088/0957-0233/6/7/028
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A four-electrode capacitance-to-period converter designed for capacitance measurements of bilayer lipid membranes is described. The capacitance measurement consists of cyclically charging and discharging the measured capacitance with a constant current, regarding its absolute value. The voltage of the studied capacitor is triangularly shaped. The cycle duration is proportional to the input capacitance. Capacitance measurement with a four-electrode system makes it possible to reduce considerably the errors caused by electrode and electrolyte impedance. It is possible to use high-resistance microelectrodes. The system makes it possible to measure the capacitance at an imposed polarization potential; the voltage oscillates about that value during the measurement. This makes it possible to measure the membrane capacitance as a function of polarization potential. An example is cited of using the capacitance-to-period converter in a computer-controlled measuring system.
引用
收藏
页码:1043 / 1049
页数:7
相关论文
共 50 条
  • [1] A 4-ELECTRODE POTENTIOSTAT-GALVANOSTAT FOR STUDIES OF BILAYER-LIPID MEMBRANES
    KALINOWSKI, S
    FIGASZEWSKI, Z
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1995, 6 (07) : 1050 - 1055
  • [2] Four-electrode system for measurement of bilayer lipid membrane capacitance
    Measurement Science & Technology, 1995, 6 (07):
  • [3] HEMATOPORPHYRIN DIMETHYL ETHER TRANSPORT ACROSS BILAYER-LIPID MEMBRANE
    STOZHKOVA, IN
    CHERNY, VV
    SOKOLOV, VS
    BIOLOGICHESKIE MEMBRANY, 1995, 12 (02): : 200 - 207
  • [4] A MICROMACHINED POLYMIDE APERTURE FOR STABLE BILAYER-LIPID MEMBRANE (BLMS)
    ERAY, M
    DOGAN, NS
    LIU, LJ
    KOCH, AR
    MOFFETT, DF
    SILBER, M
    VANWIE, BJ
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1993, 40 (11) : 2137 - 2138
  • [5] RECONSTITUTION OF A PLASMA-MEMBRANE H+-ATPASE INTO BILAYER-LIPID MEMBRANE
    ZIEGLER, W
    SLAYMAN, CL
    CARTWRIGHT, CP
    GENERAL PHYSIOLOGY AND BIOPHYSICS, 1993, 12 (05) : 429 - 443
  • [6] CORRELATIONS BETWEEN CHANGES IN MEMBRANE CAPACITANCE INDUCED BY CHANGES IN IONIC ENVIRONMENT AND THE CONDUCTANCE OF CHANNELS INCORPORATED INTO BILAYER-LIPID MEMBRANES
    CHANTURIYA, AN
    NIKOLOSHINA, HV
    JOURNAL OF MEMBRANE BIOLOGY, 1994, 137 (01): : 71 - 77
  • [7] VOLTAMMETRIC INVESTIGATION ON ION TRANSFER THROUGH A LIQUID MEMBRANE OR A BILAYER-LIPID MEMBRANE
    SHIRAI, O
    KIHARA, S
    YOSHIDA, Y
    BUNSEKI KAGAKU, 1995, 44 (11) : 905 - 920
  • [8] Electric Potential of Various 4-electrode Segmentation Excitation for Electrical Capacitance Tomography System
    Din, Shahrulnizahani Mohammad
    Azmi, Aizat
    Song, Chee Pei
    Rahim, Ruzairi Abdul
    Ling, Leow Pei
    JURNAL TEKNOLOGI, 2014, 69 (08):
  • [9] ION TRANSFER THROUGH A LIQUID MEMBRANE OR A BILAYER-LIPID MEMBRANE IN THE PRESENCE OF SUFFICIENT ELECTROLYTES
    SHIRAI, O
    KIHARA, S
    YOSHIDA, Y
    MATSUI, M
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 389 (1-2) : 61 - 70
  • [10] NONLINEAR DC ELECTRICAL RESPONSE IN A BILAYER-LIPID MEMBRANE - EFFECT OF BATHING SOLUTIONS
    BASU, R
    DE, S
    NAYAR, S
    DAS, S
    GHOSH, AK
    NANDY, P
    PHYSICAL REVIEW E, 1995, 52 (04): : 4179 - 4182