EFFECTS OF EXTRARENAL BACKGROUND SUBTRACTION AND KIDNEY DEPTH CORRECTION IN THE MEASUREMENT OF GFR BY GAMMA-CAMERA RENOGRAPHY

被引:49
作者
GRANERUS, G
MOONEN, M
机构
[1] Department of Clinical Physiology, University of Göteborg, Sahlgren's Hospital, Göteborg
关键词
D O I
10.1097/00006231-199106000-00006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Tc-99m-DTPA gamma camera renography was performed in 83 patients with a wide range of renal function. An uptake index (UI) proportional to the single kidney glomerular filtration rate (GFR) was calculated from the renograms according to two different algorithms, one based on a blood background taken from a region of interest (ROI) over the heart (method I), and the other a modification of that procedure including an extra-renal background subtraction (method II). The extra-renal background was defined by a ROI closely surrounding the kidney, making the separation between the extra-renal background and intra-renal blood background possible. Method II was further evaluated by comparing the results without and with correction for kidney depth (method III), the skin-kidney distance being measured by sonography. Calculated UI from the renograms was compared with measured Cr-51-EDTA plasma clearance as the reference method. Method I overestimated GFR at low kidney function. Addition of the extra-renal background subtraction (method II) eliminated that error and correction for kidney depth improved the accuracy (the standard error of the estimate was reduced from 18.2 min-1 to 12.3 min-1). It is concluded that the measurement of GFR by gamma camera renography is improved by these additional operations.
引用
收藏
页码:519 / 527
页数:9
相关论文
共 15 条
  • [1] Rehling M., Moller M.L., Lund J.O., Jensen K.B., Thamdrup B., Trap-Jensen J., <sup>99m</sup>Tc-DTPA gamma-camera renography. Normal values and rapid determination of single-kidney glomerular filtration rate, Eurj Nucl Med, 11, pp. 1-6, (1985)
  • [2] Moonen M., Granerus G., Subtraction of extra-renal background in<sup>99m</sup>Tc-DTPA renography: Comparison of various regions of interest, Nucl Med Commun
  • [3] Granerus G., Moonen M., Direct Measurement of GFR by Gamma Camera Renography: Importance of Extrarenal Background Subtraction and Kidney Depth Correction, (1986)
  • [4] Rutland M., Comprehensive analysis of renal DTPA studies. I. Theory and normal values, Nucl Med Commun, 6, pp. 11-20, (1985)
  • [5] Brochner-Mortensen J., A simple method for the determination of glomerular filtration rate, Scandj Clin Lab Invest, 30, pp. 271-274, (1972)
  • [6] Brochner-Mortensen J., Rodbro P., Comparison between total and renal plasma clearance of 51Cr-EDTA, Scandj Clin Lab Invest, 36, pp. 247-249, (1976)
  • [7] Rehling M., Lehd Moller M., Jensen J.J., Thamdrup B., Trap-Jensen J., Reliability of single kidney glomerular filtration rate measured by a<sup>99m</sup>Tc-DTPA gamma camera technique, Uremia Invest, 9, pp. 171-176, (1986)
  • [8] Peters A.M., Gordon I., Evans K., Todd-Pokropek A., Background in 99Tcm-DTPA renography evaluated by the impact of its components on the measurement of individual kidney glomerular rate, Nucl Med Commun, 9, pp. 545-552, (1988)
  • [9] Russel C.D., Estimation of glomerular filtration rate using<sup>99m</sup>Tc-DTPA and the gamma camera, Eur J Nucl Med, 12, pp. 548-552, (1987)
  • [10] Nimmon C.C., McAlister J.M., Cattell W.R., Kidney position and the measurement of relative uptake of 131I-Hippuran in renography, Brj Radiol, 48, pp. 286-290, (1975)