Piston diameter in stapes surgery. Does it have a bearing

被引:6
作者
Gupta, Neha [1 ]
Panda, Naresh Kumar [1 ]
Bakshi, Jaimanti [1 ]
Verma, Roshan Kumar [1 ]
Kaushal, Darwin [1 ]
机构
[1] Post Grad Inst Med Educ & Res Chandigarh, Dept Otolaryngol, Chandigarh 160012, Punjab, India
关键词
Otosclerosis; Piston diameter; Stapedotomy;
D O I
10.4103/0971-7749.129813
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Aims and Objectives: This prospective randomized controlled trial was done to study the effect of piston diameter on hearing outcomes after stapedotomy. Materials and Methods: All the patients diagnosed to have otosclerosis were included in the study. A total of 52 patients were studied ranging in age from 18 to 50 years. The subjects were randomized into two groups, that is, 0.4 mm piston (group A) and 0.6 mm piston (group B). The subjects were taken up for small fenestra stapedotomy using either a 0.4 or 0.6 mm piston. The main outcome measures were hearing improvement, air-bone gap closure, and overclosure of air-bone gap. Results: There was no statistical difference in hearing improvement in two different piston diameters, 0.4 and 0.6 mm at speech frequencies. In group A, the air-bone gap improvement in the third follow-up was not significant (P > 0.05), whereas group B showed a statistically significant improvement (P = 0.003). The mean overclosure of air-bone gap was better in patients with 0.4 mm piston at speech frequencies and also at 250 Hz. Significantly, overclosure of air-bone gap at higher frequencies (4 and 8 KHz) was seen only with a smaller sized piston. (0.4 mm). Discussion: We analyzed the effect of piston diameter on the hearing results after small fenestra stapedotomy by using similar surgical procedure and similar prosthesis in all patients. Conclusion: There is evidence to suggest that 0.4 mm piston may be better suited for providing optimum hearing results.
引用
收藏
页码:33 / 36
页数:4
相关论文
共 13 条
[1]  
CAWTHORNE T, 1955, J Laryngol Otol, V69, P437, DOI 10.1017/S0022215100050933
[2]  
Donaldson JA, 1992, OTOLARYNGOLOGY HEAD, P2997
[3]   Effects of Fenestra Size and Piston Diameter on the Outcome of Stapes Surgery for Clinical Otosclerosis [J].
Gristwood, Ronald Edward ;
Venables, William Norman .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2011, 120 (06) :363-371
[4]   A retrospective study of the hearing results obtained after stapedotomy by the implantation of two Teflon pistons with a different diameter [J].
Grolman, W ;
Tange, RA ;
de Bruijn, AJG ;
Hart, AAM ;
Schouwenburg, PF .
EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 1997, 254 (9-10) :422-424
[5]  
KARTUSH JM, 1994, OTOLARYNG CLIN N AM, V27, P689
[6]  
Laske R, 2010, OTOLARYNGOL HEAD NEC, V143, P245
[7]   The Influence of Prosthesis Diameter in Stapes Surgery: A Meta-Analysis and Systematic Review of the Literature [J].
Laske, Roman D. ;
Roeoesli, Christof ;
Chatzimichalis, Michail Vasileios ;
Sim, Jae Hoon ;
Huber, Alexander M. .
OTOLOGY & NEUROTOLOGY, 2011, 32 (04) :520-528
[8]   Hearing results after stapedotomy: Role of the prosthesis diameter [J].
Marchese, Maria Raffaella ;
Cianfrone, Francesca ;
Passali, Giulio Cesare ;
Paludetti, Gaetano .
AUDIOLOGY AND NEURO-OTOLOGY, 2007, 12 (04) :221-225
[9]   CONSIDERATIONS ABOUT SURGICAL APPROACH IN STAPEDECTOMY [J].
MARQUET, J ;
VANCAMP, KJ ;
CRETEN, WL .
ACTA OTO-LARYNGOLOGICA, 1972, 74 (06) :406-&
[10]   SURGERY FOR HEARING LOSS [J].
SCHUKNECHT, HF ;
APPLEBAUM, EL .
NEW ENGLAND JOURNAL OF MEDICINE, 1969, 280 (21) :1154-+