DELAY-LINE READOUTS FOR HIGH-PURITY GERMANIUM MEDICAL IMAGING CAMERAS

被引:13
|
作者
KAUFMAN, L
CAMP, DC
MCQUAID, JH
ARMANTRO.GA
SWIERKOW.SP
机构
[1] UNIV CALIF,SAN FRANCISCO,CA 94102
[2] LAWRENCE LIVERMORE LAB,LIVERMORE,CA
[3] LAWRENCE BERKELEY LAB,BERKELEY,CA
关键词
D O I
10.1109/TNS.1974.4327528
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
引用
收藏
页码:652 / 657
页数:6
相关论文
共 50 条
  • [1] GROOVELESS HIGH-PURITY GERMANIUM GAMMA-RAY CAMERA WITH DELAY-LINE READOUTS
    ARMANTROUT, G
    CAMP, D
    MCQUAID, J
    GALWEY, R
    OKUBO, D
    KAUFMAN, L
    HATTNER, R
    PRICE, D
    SWANN, S
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1974, 19 (OCT27): : 45 - 45
  • [2] HIGH-RESOLUTION DELAY-LINE READOUTS FOR MICROCHANNEL PLATES
    SIEGMUND, OHW
    LAMPTON, M
    RAFFANTI, R
    HERRICK, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 310 (1-2): : 311 - 316
  • [3] HIGH-RESOLUTION DELAY-LINE READOUTS FOR ASTRONOMICAL SPECTROSCOPY
    SIEGMUND, OHW
    RAFFANTI, R
    STOCK, J
    HERRICK, W
    LAMPTON, M
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1992, (121): : 123 - 130
  • [4] HIGH SPATIAL RESOLUTION MWPC SYSTEMS USING ELECTROMAGNETIC DELAY-LINE READOUTS
    SWANSON, FR
    KUEHNE, FJ
    FAVALE, AJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1973, NS20 (01) : 160 - 165
  • [5] BIOMEDICAL APPLICATIONS OF PROPORTIONAL WIRE CHAMBERS WITH DELAY-LINE READOUTS
    KAPLAN, SN
    KAUFMAN, L
    VALENTIN.K
    SPERINDE, J
    PEREZMEN.V
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1972, 17 (04): : 482 - &
  • [6] CARBON IN HIGH-PURITY GERMANIUM
    HALLER, EE
    HANSEN, WL
    LUKE, P
    MCMURRAY, R
    JARRETT, B
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1982, 29 (01) : 745 - 750
  • [7] ADAPTATION OF MULTI-WIRE PROPORTIONAL CHAMBERS WITH DELAY-LINE READOUTS FOR NEUTRON RADIOGRAPHIC IMAGING
    VALENTINE, K
    KAUFMAN, L
    KAPLAN, S
    PEREZMEN.V
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1972, NS19 (01) : 374 - +
  • [8] RESOLUTION RECOVERY IN PLANAR NUCLEAR IMAGES - APPLICATION TO HIGH-PURITY GERMANIUM AND SCINTILLATION CAMERAS
    ORTENDAHL, DA
    SHOSA, DW
    KAUFMAN, L
    ROWAN, W
    OCONNELL, JW
    HATTNER, RS
    HERFKENS, R
    JOURNAL OF NUCLEAR MEDICINE, 1980, 21 (06) : P38 - P38
  • [9] CHARACTERISTICS OF A HIGH-PURITY GERMANIUM DETECTOR
    THOMAS, GE
    PEHL, RH
    NUCLEAR INSTRUMENTS & METHODS, 1974, 121 (01): : 65 - 67
  • [10] CARRIER TRAPPING IN HIGH-PURITY GERMANIUM
    SCHOENMAEKERS, WKH
    CLAUWS, P
    VANDENSTEEN, K
    BROECKX, J
    HENCK, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (01) : 256 - 264