Patient specific cup anteversion in total hip arthroplasty: a computed tomography study investigating the use of the transverse acetabular ligament to control cup placement

被引:3
作者
Archbold, H. A. P. [1 ]
Slomczykowski, M. [2 ]
Cairns, H. [1 ]
Eckman, Kort [3 ]
Jaramaz, Branislav [4 ]
Beverland, D. E. [1 ]
机构
[1] Musgrave Pk Hosp, Outcomes Unit, Belfast BT9 7JB, Antrim, North Ireland
[2] Johnson & Johnson Co, DePuy Int, Leeds LS11 0EA, W Yorkshire, England
[3] Carnegie Mellon Univ, Robot Inst, Pittsburgh, PA 15213 USA
[4] Western Penn Hosp, Inst Comp Assisted Surg, Pittsburgh, PA USA
来源
CURRENT ORTHOPAEDIC PRACTICE | 2009年 / 20卷 / 01期
关键词
acetabular component orientation; transverse acetabular ligament;
D O I
10.1097/BCO.0b013e3181944dd2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Ensuring optimal position of the acetabular component during total hip arthroplasty is a complex problem. Although computer assisted techniques have been developed to achieve this, these systems may result in improper cup alignment caused by errors in registration of the anterior pelvic plane. Furthermore, set goals for cup placement do not reflect the variation in acetabular morphology. Aneed exists to developamethodfor cuppositioning that is patient specific and eliminates the need to register the anterior pelvic plane. It is our hypothesis that the transverse acetabular ligament can be used to do this. The objective of this study was to define the version of acetabular components placed using this technique. Methods In this series of 40 consecutive primary hip replacements, the transverse acetabular ligament was used as the sole method to define cup version. Postoperative CT scans of the pelvis were analyzed tomeasure the anteversion of the acetabular component. Results At a minimum follow-up of 12 months (range 12-18 months), none of the hips dislocated. Using the transverse acetabular ligament as the sole method to control the version of the acetabular component resulted in an average radiographic anteversion of 19.78 +/- 8.18 (mean +/- standard deviation) which equates to an operative anteversion of 28.18 +/- 11.38 (mean +/- standard deviation). Conclusions This paper highlights the variation in cup version when the transverse acetabular ligament is used to establish and control cup placement. This questions the one-size-fits-all philosophy of a set goal for cup positioning.
引用
收藏
页码:73 / 76
页数:4
相关论文
共 28 条
  • [1] The transverse acetabular ligament: an aid to orientation of the acetabular component during primary total hip replacement - A preliminary study of 1000 cases investigating postoperative stability
    Archbold, H. A. P.
    Mockford, B.
    Molloy, D.
    McConway, J.
    Ogonda, L.
    Beverland, D.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (07): : 883 - 886
  • [2] Biedermann R, 2005, J BONE JOINT SURG BR, V87B, P762, DOI 10.1302/0301-620X.87B6
  • [3] Optimizing acetabular component position to minimize impingement and reduce contact stress
    D'Lima, DD
    Chen, PC
    Colwell, CW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A : 87 - 91
  • [4] DiGioia A M, 1998, Clin Orthop Relat Res, P8
  • [5] Comparison of a mechanical acetabular alignment guide with computer placement of the socket
    DiGioia, AM
    Jaramaz, B
    Plakseychuk, AY
    Moody, JE
    Nikou, C
    LaBarca, RS
    Levison, TJ
    Picard, F
    [J]. JOURNAL OF ARTHROPLASTY, 2002, 17 (03) : 359 - 364
  • [6] The etiology of osteoarthritis of the hip - An integrated mechanical concept
    Ganz, Reinhold
    Leunig, Michael
    Leunig-Ganz, Katharina
    Harris, William H.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (02) : 264 - 272
  • [7] Accuracy of intraoperative assessment of acetabular prosthesis placement
    Hassan, DM
    Johnston, GHF
    Dust, WNC
    Watson, G
    Dolovich, AT
    [J]. JOURNAL OF ARTHROPLASTY, 1998, 13 (01) : 80 - 84
  • [8] Computer assisted measurement of cup placement in total hip replacement
    Jaramaz, B
    DiGioia, AM
    Blackwell, M
    Nikou, C
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (354) : 70 - 81
  • [9] Factors predisposing to dislocation after primary total hip arthroplasty - A multivariate analysis
    Jolles, BM
    Zangger, P
    Leyvraz, PF
    [J]. JOURNAL OF ARTHROPLASTY, 2002, 17 (03) : 282 - 288
  • [10] Computer-assisted cup placement techniques in total hip arthroplasty improve accuracy of placement
    Jolles, BM
    Genoud, P
    Hoffmeyer, P
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (426) : 174 - 179