COUPLING TECHNIQUES IN LC MS AND SFC MS

被引:31
作者
ARPINO, P
机构
[1] Laboratoire de Chimie Analytique, Institut National Agronomique, Paris, F-75005
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1990年 / 337卷 / 06期
关键词
D O I
10.1007/BF00323101
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Techniques and applications of analytical instruments combining a chromatographic technique, including liquid chromatography and supercritical fluid chromatography, with mass spectrometry (LC/MS and SFC/MS), that have appeared over the past five years, are reviewed and discussed. It is shown that still many different methods co-exist and have both specific advantages and limitations. SFC/MS appears easier to run for many compounds so far analysed by conventional LC/MS methods. On the other hand, new LC/MS methods that use fast atom bombardment or electrospray ionization have the greater potential for the investigation of polar biopolymers. © 1990 Springer-Verlag.
引用
收藏
页码:667 / 685
页数:19
相关论文
共 242 条
[1]   DIRECT ANALYSIS OF THE MAJOR HUMAN SEMINAL PROSTAGLANDINS BY THERMOSPRAY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
ABIAN, J ;
GELPI, E .
JOURNAL OF CHROMATOGRAPHY, 1987, 394 (01) :147-153
[2]   MEASUREMENT OF OCHRATOXIN-A IN BARLEY EXTRACTS BY LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY [J].
ABRAMSON, D .
JOURNAL OF CHROMATOGRAPHY, 1987, 391 (01) :315-320
[3]   MICRO LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY WITH LOW FLOW GRADIENT ELUTION - STUDIES OF ELECTROSTATIC NEBULIZATION AND FUSED-SILICA COLUMN DESIGN [J].
ALBORN, H ;
STENHAGEN, G .
JOURNAL OF CHROMATOGRAPHY, 1987, 394 (01) :35-49
[4]   THERMOSPRAY MASS-SPECTROMETRY - USE OF GAS-PHASE ION MOLECULE REACTIONS TO EXPLAIN FEATURES OF THERMOSPRAY MASS-SPECTRA [J].
ALEXANDER, AJ ;
KEBARLE, P .
ANALYTICAL CHEMISTRY, 1986, 58 (02) :471-478
[5]   MICRO POST-COLUMN EXTRACTION SYSTEM FOR INTERFACING REVERSED-PHASE MICRO LIQUID-CHROMATOGRAPHY AND MASS-SPECTROMETRY [J].
APFFEL, JA ;
BRINKMAN, UAT ;
FREI, RW .
JOURNAL OF CHROMATOGRAPHY, 1984, 312 (NOV) :153-164
[7]   OPTIMIZATION OF THE INSTRUMENTAL PARAMETERS OF A COMBINED LIQUID CHROMATOGRAPH-MASS SPECTROMETER, COUPLED BY AN INTERFACE FOR DIRECT LIQUID INTRODUCTION .2. NEBULIZATION OF LIQUIDS BY DIAPHRAGMS [J].
ARPINO, PJ ;
KRIEN, P ;
VAJTA, S ;
DEVANT, G .
JOURNAL OF CHROMATOGRAPHY, 1981, 203 (JAN) :117-130
[8]   OPTIMIZATION OF THE INSTRUMENTAL PARAMETERS OF A COMBINED LIQUID CHROMATOGRAPH MASS-SPECTROMETER COUPLED BY AN INTERFACE FOR DIRECT LIQUID INTRODUCTION .5. DESIGN AND CONSTRUCTION OF LC MS INTERFACES UTILIZING FUSED-SILICA CAPILLARY TUBES AS VACUUM NEBULIZERS [J].
ARPINO, PJ ;
BEAUGRAND, C .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1985, 64 (03) :275-298
[9]   SUPERCRITICAL FLUID CHROMATOGRAPHY-MASS SPECTROMETRY COUPLING [J].
ARPINO, PJ ;
COUSIN, J ;
HIGGINS, J .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1987, 6 (03) :69-73
[10]  
ARPINO PJ, 1990, IN PRESS MASS SPECTR